1. Úvod
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Chatsworth P5-1C0A5 Switched Vertical eConnect Power Distribution Unit (PDU). Please read this manual thoroughly before using the product and retain it for future reference.
2. Bezpečnostní informace
Observe the following safety precautions to prevent injury and damage to the PDU or connected equipment:
- Zajistěte, aby PDU instaloval kvalifikovaný personál v souladu se všemi místními a národními elektrotechnickými předpisy.
- Do not open the PDU enclosure. There are no user-serviceable parts inside.
- PDU připojujte pouze k řádně uzemněnému zdroji napájení.
- Do not overload the PDU. The total current draw of connected devices must not exceed the PDU's rated capacity (20A).
- Operate the PDU within its specified environmental conditions, including the maximum ambient temperature of 149°F (65°C).
- Před prováděním jakékoli údržby nebo instalace odpojte napájení.
3. Konec produktuview
The Chatsworth P5-1C0A5 is a Switched Vertical eConnect PDU designed for efficient power distribution and remote management in data center environments. It features 24 individually switched 5-20R outlets, a graphical local display, and comprehensive network monitoring capabilities.

Obrázek 1: Konecview of the Chatsworth P5-1C0A5 PDU. This image displays the vertical PDU with its numerous 5-20R outlets, labeled circuit breakers (CB1, CB2, CB3), and the integrated control panel featuring a graphical display, navigation buttons, Ethernet ports, and a USB port.
Klíčové komponenty:
- L5-20 Input Plug: For connecting the PDU to the main power source.
- Circuit Breakers (CB1, CB2, CB3): Provide overcurrent protection for groups of outlets. Each breaker has an ON/OFF switch.
- 5-20R Outlets: Twenty-four (24) individually switched outlets for connecting IT equipment.
- Graphical Local Display: Provides real-time power monitoring, configuration, and status information directly on the unit.
- Ethernetové porty: For network connectivity, enabling IP-based remote monitoring and management.
- USB port: Used for firmware updates and configuration backups.
- Sériový port: For direct console access and management.
4. Nastavení
4.1 Montáž
The P5-1C0A5 is a vertical PDU designed for tool-less mounting in standard server racks. Ensure the rack has appropriate mounting points and sufficient space for the PDU and its connected cables. Refer to your rack's documentation for specific mounting instructions.
4.2 Připojení napájení
- Ensure all circuit breakers on the PDU are in the OFF position.
- Connect the PDU's L5-20 input plug to a dedicated 1-Phase, 110-125V, 20A power circuit.
- Verify the power source is properly grounded.
4.3 Připojení zařízení
- With the PDU still powered off (breakers OFF), connect your IT equipment power cords to the 5-20R outlets on the PDU.
- Distribute the load evenly across the PDU's outlets and circuit breaker groups to prevent overloading any single breaker.
4.4 Síťové připojení
For remote monitoring and management, connect an Ethernet cable from your network switch to one of the Ethernet ports on the PDU's control panel. Refer to the PDU's network configuration guide for initial setup of IP addresses and network settings.
5. Provoz
5.1 Zapnutí/vypnutí
- After connecting all equipment, switch the main circuit breakers (CB1, CB2, CB3) on the PDU to the ON position.
- The graphical local display will illuminate, indicating the PDU is operational.
- Individual outlets can be switched ON or OFF via the local display interface or remotely through the network interface.
5.2 Local Display Operation
Use the navigation buttons adjacent to the graphical display to browse through menus, view real-time power metrics (voltage, current, power, energy), and configure basic settings. Consult the detailed eConnect PDU user guide for comprehensive local display functionality.
5.3 Vzdálené monitorování a správa
Access the PDU's web interface via its assigned IP address to perform advanced monitoring, configuration, and control. This includes:
- Real-time power monitoring of the entire PDU and individual outlets.
- Individual outlet switching and sequencing.
- Setting up alerts and notifications for power events.
- User management and security settings.
The PDU also supports serial monitoring for direct console access.
6. Údržba
6.1 Čištění
Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure the PDU is powered off and disconnected from the power source before cleaning.
6.2 aktualizací firmwaru
Chatsworth may release firmware updates to improve performance or add new features. These updates can typically be applied via the USB port or through the network interface. Refer to the Chatsworth support webstránky s nejnovějším firmwarem a pokyny k aktualizaci.
6.3 Environmentální hlediska
The PDU is designed to operate in high ambient temperatures up to 149°F (65°C). Ensure proper airflow around the unit to prevent overheating. Regularly check the operating environment to ensure it remains within specified limits.
7. Řešení problémů
7.1 No Power to Outlets
- Verify the main L5-20 input plug is securely connected to a live power source.
- Check if the PDU's circuit breakers (CB1, CB2, CB3) are in the ON position. If a breaker has tripped, switch it OFF, wait a few seconds, and then switch it back ON. If it trips again, reduce the load on that breaker.
- Confirm that individual outlets are switched ON via the local display or remote interface.
7.2 Problémy s připojením k síti
- Ensure the Ethernet cable is securely connected to both the PDU and the network switch.
- Verify network settings (IP address, subnet mask, gateway) on the PDU are correct.
- Check network switch port status and connectivity.
7.3 Breaker Trips Repeatedly
A repeatedly tripping breaker indicates an overload condition. Reduce the total current draw of devices connected to that breaker's group of outlets. If the issue persists with a reduced load, contact technical support.
8. Specifikace
| Funkce | Specifikace |
|---|---|
| Číslo modelu | P5-1C0A5 |
| Značka | Chatsworth |
| Vstupní zástrčka | L5-20 |
| Vstupní objemtage | 1-Phase, 110-125V |
| Vstupní proud | 20A |
| Vývody | (24) 5-20R Outlets |
| Jističe | 1 x 2P 20A Hydraulic Magnetic Breakers |
| Ochrana proti přepětí | Žádný |
| Sledování | Ethernet, IP, Serial, USB, Graphical Local Display |
| Provozní teplota | Až 149 °F (65 °C) |
| Approximate Dimensions (Package) | 82 x 10 x 8 palce |
| UPC | 703957370393 |
9. Záruka a podpora
For warranty information, technical support, or service inquiries, please contact Chatsworth Products customer service or visit their official webwebu. Při kontaktování podpory mějte po ruce účtenku o koupi a sériové číslo produktu.