Hilitand NLQ3-125/2P

Hilitand NLQ3-125/2P 110V 63A Automatic Transfer Switch User Manual

Model: NLQ3-125/2P | Brand: Hilitand

1. Úvod

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Hilitand NLQ3-125/2P Automatic Transfer Switch (ATS). This device is designed to automatically switch between a normal power supply and a standby power supply, such as a PV inverter or generator, ensuring continuous power for critical loads.

2. Bezpečnostní informace

Please read all safety warnings and instructions carefully before installing or operating this device. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Instalaci a údržbu by měli provádět pouze kvalifikovaní elektrikáři.
  • Před zahájením jakékoli kabeláže nebo údržby se ujistěte, že jsou odpojeny všechny zdroje napájení.
  • Ověřte správný objemtagPřed připojením zařízení zkontrolujte elektrické napájení a jmenovitý proud.
  • Nepoužívejte spínač, pokud se jeví poškozený.
  • Always use appropriate personal protective equipment (PPE).

3. Konec produktuview

The Hilitand NLQ3-125/2P is a 110V 63A 2-pole automatic transfer switch featuring millisecond switching capabilities. It is designed for applications requiring uninterrupted power, such as in homes, shopping malls, factories, laboratories, and farms. The switch ensures continuity, reliability, and safety of the power supply by automatically transferring to a backup source when the normal supply is abnormal.

Klíčové vlastnosti:

  • Automatický převod: Seamlessly switches between normal and standby power supplies.
  • Millisecond Switching: Ensures minimal interruption to power supply.
  • Odolná konstrukce: Made from flame-retardant PC material and silver alloy contacts for good insulation and aging resistance.
  • Široká aplikace: Suitable for various environments requiring continuous power.
  • Isolation and Interference Resistant: Navrženo pro spolehlivý výkon.

Součásti produktu:

Hilitand NLQ3-125/2P Automatic Transfer Switch front view

Obrázek 3.1: Přední view of the Hilitand NLQ3-125/2P Automatic Transfer Switch, showing input/output terminals, manual/auto selector, and power indicators.

Hilitand NLQ3-125/2P Automatic Transfer Switch top view s popisky

Obrázek 3.2: Nahoru view of the Automatic Transfer Switch, highlighting the 'Normal Power A' and 'Reverse Power B' sections, along with the manual/auto switch and terminal connections.

Hilitand NLQ3-125/2P Automatic Transfer Switch bottom view

Obrázek 3.3: Dno view of the Automatic Transfer Switch, showing the base and a production process label.

4. Specifikace

ParametrHodnota
Model produktuNLQ3-125/2P
Typ položkyDual Power Automatický přenosový spínač
MateriálFlame Retardant PC, Silver Alloy
Typ přepínačeSekundární distribuce
Jmenovitý proud63A
Coil Voltage110V AC
Izolace svtageAC690V AC
Jmenovitý objemtageAC400V AC (Note: Product title states 110V, please verify application voltage)
Jmenovitá frekvence50/60 Hz
Elektrická úroveňPC Isolation Type
Ohodnocený Impulse Withstand Voltage8KV
Control Circuit Rated Control Voltage NásAC110V 85% Us-110% Us
Pomocný obvod2 Relays, each with 2 sets of contacts capacity: AC110V50HZ le=5y
Rozměry balíku11 x 10 x 8 cm
Hmotnost606 g
Hilitand NLQ3-125/2P Automatic Transfer Switch with dimensions

Obrázek 4.1: Dimensions of the Hilitand NLQ3-125/2P Automatic Transfer Switch, showing approximate measurements of 109mm (4.3in) length, 97mm (3.8in) width, and 69mm (2.7in) height.

5. Nastavení a instalace

Proper installation is crucial for the safe and reliable operation of the ATS. Refer to the wiring diagram and follow local electrical codes.

Kontrola před instalací:

  1. Before installation, carefully inspect the integrity of the ATS for any physical damage.
  2. Use the operating handle to manually open or close the ATS. Check the flexibility of the internal transmission device.
  3. Test the generation and disconnection conditions of the load for both the normal and standby power supply in each phase to ensure proper functionality before final wiring.

Schéma zapojení:

Hilitand NLQ3-125/2P Automatic Transfer Switch wiring diagram

Obrázek 5.1: Wiring diagram for the Automatic Transfer Switch. It illustrates connections for Common Feed, Common Control Line, Back-up Line, Stand-by Control Line, and Load Output for both Normal Power A (Solar Energy) and Reverse Power B (City Power).

Kroky instalace:

  1. Mount the ATS securely in a suitable enclosure, ensuring adequate ventilation and clearance.
  2. Connect the normal power supply (e.g., grid power) to the designated 'Normal Power A' input terminals.
  3. Connect the standby power supply (e.g., PV inverter or generator) to the designated 'Reverse Power B' input terminals.
  4. Connect the load to the output terminals of the ATS.
  5. Connect the control lines as per the wiring diagram. Ensure all connections are tight and secure.
  6. Double-check all wiring for correctness and adherence to safety standards before applying power.

6. Návod k obsluze

The NLQ3-125/2P ATS can operate in both automatic and manual modes.

Automatický režim:

  • Set the selector switch on the device to 'Auto'.
  • In this mode, the ATS will automatically monitor the normal power supply.
  • If the normal power supply fails or falls outside acceptable parameters, the ATS will automatically switch the load to the standby power supply within milliseconds.
  • When the normal power supply is restored, the ATS will automatically transfer the load back to the normal power supply.

Manuální režim:

  • Set the selector switch on the device to 'Manual'.
  • In manual mode, the user can use the operating handle to switch between 'Normal Power A' and 'Reverse Power B' as needed.
  • This mode is typically used for testing, maintenance, or in situations where automatic transfer is not desired.

Aplikace Přamples:

Hilitand NLQ3-125/2P Automatic Transfer Switch application examples

Obrázek 6.1: Vizuální examples of environments where the ATS can be applied, including household electricity, shopping malls, company offices, and factories, demonstrating its versatility.

Hilitand NLQ3-125/2P Automatic Transfer Switch in various settings

Obrázek 6.2: Another illustration of the ATS's broad applicability, showing it in contexts such as factories, shopping malls, nurseries, and residential buildings with solar panels, emphasizing its use where continuous power is critical.

Hilitand NLQ3-125/2P Automatic Transfer Switch in an industrial setting

Obrázek 6.3: The Automatic Transfer Switch positioned within an industrial manufacturing environment, highlighting its suitability for robust and demanding operational settings.

7. Údržba

Pravidelná údržba pomáhá zajistit dlouhou životnost a spolehlivý provoz vašeho ATS.

  • Pravidelná prohlídka: Regularly inspect the ATS for any signs of wear, damage, or loose connections.
  • Čištění: Udržujte zařízení čisté a bez prachu a nečistot. K čištění používejte suchý, měkký hadřík. Nepoužívejte tekuté čisticí prostředky.
  • Kontrola terminálu: Periodically check all terminal connections to ensure they are tight and secure. Loose connections can lead to overheating and potential failure.
  • Funkční test: Conduct periodic functional tests (in manual mode, if safe to do so) to ensure the switching mechanism operates smoothly.
  • Profesionální servis: For any complex issues or internal inspections, consult a qualified electrician.

8. Řešení problémů

If you encounter issues with your ATS, refer to the following common problems and solutions:

ProblémMožná příčinaŘešení
ATS does not switch automatically1. Selector switch in 'Manual' mode.
2. No power detected on standby source.
3. Control circuit fault.
1. Set selector switch to 'Auto'.
2. Verify standby power source is active.
3. Consult a qualified electrician.
Žádný výstupní výkon1. Both normal and standby power sources are off.
2. Loose wiring connections.
3. Vnitřní porucha.
1. Check both power sources.
2. Inspect and tighten all wiring connections (with power off).
3. Consult a qualified electrician.
Overheating of terminals1. Uvolněné spoje.
2. Přetížení.
3. Incorrect wire gauge.
1. Tighten all terminal screws (with power off).
2. Reduce load or verify load is within rated capacity.
3. Ensure appropriate wire gauge is used for the current rating.

For issues not listed above or if solutions do not resolve the problem, contact customer support or a qualified electrician.

9. Záruka a podpora

Informace o záruce:

This Hilitand product comes with a manufacturer warranty for 90 days from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications.

Zákaznická podpora:

For technical assistance, warranty claims, or further inquiries, please contact Hilitand customer support through your retailer or the official Hilitand channels. Please have your product model number (NLQ3-125/2P) and purchase details ready when contacting support.

© 2024 Hilitand. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.