IXITAB KWS-AC301, KWS-AC300

IXITAB KWS-AC301 & KWS-AC300 Digital AC Power Energy Meter User Manual

Models: KWS-AC300, KWS-AC301, KWS-AC301L

1. Úvod

This manual provides detailed instructions for the installation, operation, and maintenance of the IXITAB KWS-AC301 and KWS-AC300 series Digital AC Power Energy Meters. These devices are designed to measure and display various electrical parameters including voltage, current, power, energy consumption (Kwh), timing, temperature, frequency, and power factor (for KWS-AC301 models). Please read this manual thoroughly before use to ensure proper and safe operation.

2. Bezpečnostní informace

  • Před instalací nebo zapojováním se ujistěte, že je veškeré napájení odpojeno, abyste předešli úrazu elektrickým proudem.
  • Instalaci by měl provádět pouze kvalifikovaný personál.
  • Neprovozujte zařízení ve vlhku nebo damp podmínky.
  • Nepřekračujte stanovený objemtage and current ratings of the meter.
  • Před připojením napájení zkontrolujte, zda jsou všechna připojení zajištěna.

3. Vlastnosti produktu

The IXITAB KWS-AC300 and KWS-AC301 series meters offer comprehensive monitoring of AC electrical parameters:

  • Real-time display of AC Voltage (V), Current (A), and Active Power (W).
  • Measurement of cumulative Electrical Energy (Kwh) and Timing (H).
  • Měření teploty.
  • Frequency measurement (Hz).
  • Power Factor measurement (PF) (KWS-AC301 models only).
  • Electrical energy and timing reset function.
  • Power-down memory function for electrical energy and timing.
  • Optional 485 communication interface for data transmission (KWS-AC301L models).

4. Specifikace

KWS-AC300 Series

ParametrAC300-20AAC300-100A
svtageAC 50-300VAC 50-300V
Proud0-20A0-100A
Moc0-3000W0-30kW
Capacity (Kwh)0.01–19999 kWh0.01–19999 kWh
Načasování0-200H0-200H
Teplota-10 °C až 99 °C-10 °C až 99 °C
Frekvence45-65Hz45-65Hz

KWS-AC301 Series

ParametrAC301-20A / AC301L-20AAC301-100A / AC301L-100A
svtageAC 50-300VAC 50-300V
Proud0-20A0-100A
Shunt WayVestavěnýVestavěný
485 KomunikaceAC301-20A: No, AC301L-20A: YesAC301-100A: No, AC301L-100A: Yes
Moc0-4400W0-22kW
Capacity (Kwh)0.01–99999 kWh0.01–99999 kWh
Načasování0-999H0-999H
Teplota-10 °C až 150 °C-20 °C až 150 °C
Frekvence50-60Hz50-60Hz
Účiník0.01-1PF0.01-1PF

Note: Dimensions for KWS-AC300 are approximately 79mm x 37.5mm x 20.7mm. Dimensions for KWS-AC301 are approximately 73mm x 44mm x 24mm. Both models use a CT coil with a diameter of 15mm.

Dimensions of KWS-AC300 and KWS-AC301 meters and their CT coils

Figure 4.1: Physical dimensions of KWS-AC300 and KWS-AC301 models, including CT coil measurements.

5. Obsah balení

  • 1 x Digital AC Power Energy Meter (KWS-AC300 or KWS-AC301 model)
  • 1 x Uživatelská příručka
  • For 100A models: 1 x 100A Shunt / CT Coil
  • For 20A models: No external shunt/CT Coil (built-in)

6. Nastavení a instalace

Pro správnou instalaci pečlivě dodržujte tyto kroky:

6.1 Wiring Diagram (KWS-AC301L-100A Example)

The following diagram illustrates the wiring for the KWS-AC301L-100A model with a closed sensor (CT coil). Ensure all connections are made correctly before applying power.

Wiring diagram for KWS-AC301L-100A with closed sensor and CT coil

Figure 6.1: Wiring connections for the KWS-AC301L-100A model, showing input voltage (IN-AC), load connection, and CT coil placement around the live wire.

  • Příkon: Connect the AC 50-300V power supply to terminals L and N (typically labeled 3 and 4 on the meter).
  • Načíst připojení: Connect the load in series with the live wire (L). The CT coil should be placed around the live wire that feeds the load.
  • CT Coil: Connect the CT coil wires to the designated CT terminals on the meter (typically labeled 1 and 2). Ensure the direction of the CT coil is correct as indicated by any arrows on the coil or meter.
  • 20A Models: For 20A models without an external CT coil, the current measurement is internal. Connect the AC 50-300V power supply to the meter's input terminals, and the load directly through the meter's designated load terminals.

6.2 485 Communication and Temperature Sensor (KWS-AC301L Models)

For KWS-AC301L models, additional interfaces are available for 485 communication and an external temperature sensor.

KWS-AC301L with 485 communication and temperature sensor interfaces

Figure 6.2: KWS-AC301L model showing the dedicated interfaces for the temperature sensor and 485 communication (RS485 A+ and B- terminals).

  • Teplotní senzor: Connect the external temperature sensor to the dedicated interface.
  • 485 Rozhraní: Connect the RS485 A+ and B- terminals to your 485 communication network for data acquisition. PC software may be available for data logging and analysis (refer to product documentation or manufacturer's website for download links).

7. Provoz

The meter features a clear digital display and intuitive buttons for navigation and settings.

7.1 Zobrazení nadview

KWS-AC300 and KWS-AC301 meter displays showing various parameters

Figure 7.1: Top display shows KWS-AC300 with Voltage, Current, Power, Timing, and Kwh. Bottom display shows KWS-AC301 with Voltage, Current, Power, Timing, Kwh, Power Factor, and Frequency.

The display shows various parameters simultaneously. The KWS-AC300 typically displays Voltage, Current, Power, Timing, and Kwh. The KWS-AC301 models additionally display Frequency and Power Factor.

7.2 Funkce tlačítek

The meters typically feature one or more buttons for interaction:

  • KWS-AC300: Features a "MENU" button. Pressing this button allows cycling through display modes or accessing settings.
  • KWS-AC301: Features three buttons: Up (Δ), Middle (M), and Down (∇).
KWS-AC301 button interaction for settings and alarm values

Figure 7.2: KWS-AC301 button interaction. Pressing the 'M' button for 3 seconds allows entry into setting or alarm value adjustment modes.

  • "M" Button (KWS-AC301):
    • Krátký tisk: Cycles through different display parameters (e.g., Voltage, Current, Power, Kwh, Timing, Temperature).
    • Dlouhé stisknutí (3 sekundy): Enters the setting mode or alarm value adjustment mode. Use the Up (Δ) and Down (∇) buttons to navigate and adjust values.
  • Up (Δ) and Down (∇) Buttons (KWS-AC301): Used to navigate menus, increase or decrease values in setting modes.

7.3 Resetting Electrical Energy and Timing

To reset the cumulative electrical energy (Kwh) and timing (H) values, typically a long press on a specific button (often the "M" or "MENU" button) while in the Kwh or Timing display mode will initiate the reset process. Confirm the reset if prompted by the display.

8. Údržba

  • Udržujte měřič čistý a bez prachu. K čištění používejte měkký, suchý hadřík.
  • Nevystavujte zařízení extrémním teplotám, přímému slunečnímu záření nebo korozivnímu prostředí.
  • Do not attempt to open or repair the meter yourself, as this may void the warranty and pose a safety risk.
  • Ensure all wiring connections remain secure over time.

9. Řešení problémů

  • Bez displeje:
    • Check if the power supply (AC 50-300V) is connected correctly and active.
    • Zajistěte vstupní objtage je ve specifikovaném rozsahu.
  • Incorrect Current/Power Reading:
    • For 100A models, verify the CT coil is correctly installed around the live wire and connected to the meter.
    • Ensure the CT coil direction is correct.
    • Check if the load is properly connected.
  • Parameters Not Resetting:
    • Refer to Section 7.3 for the correct procedure to reset Kwh and Timing. Ensure the button is pressed for the required duration.
  • 485 Communication Issues (KWS-AC301L):
    • Verify the A+ and B- connections are correct.
    • Check communication settings (baud rate, parity, stop bits) on both the meter and the connected device.

10. Záruka a podpora

Pro informace o záruce, technickou podporu nebo servisní dotazy se obraťte na výrobce nebo autorizovaného prodejce. Uschovejte si účtenku jako doklad o koupi.

Manufacturer: IXITAB

© 2023 IXITAB. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.