NJOY Echo Pro 2000

NJOY Echo Pro 2000 UPS Server User Manual

Model: Echo Pro 2000 | Brand: NJOY

1. Úvod

The NJOY Echo Pro 2000 is an advanced Uninterruptible Power Supply (UPS) designed to provide reliable power protection for critical equipment such as servers, workstations, and networking devices. Featuring double conversion online technology, it delivers a pure sine wave output, ensuring the highest degree of compatibility and protection for sensitive electronics. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Echo Pro 2000 UPS.

NJOY Echo Pro 2000 UPS front view

Obrázek 1.1: Přední strana view of the NJOY Echo Pro 2000 UPS. This image shows the main unit with its front panel display and control buttons.

2. Bezpečnostní informace

Please read and follow all safety instructions carefully before installing, operating, or servicing the UPS. Failure to comply with these instructions may result in electric shock, fire, or serious injury.

  • Elektrická bezpečnost: UPS obsahuje nebezpečné látkytagNepokoušejte se jednotku rozebírat. Servis by měl provádět pouze kvalifikovaný personál.
  • Bezpečnost baterie: Batteries can present a risk of electrical shock and high short-circuit current. Observe proper polarity when connecting batteries. Do not dispose of batteries in a fire.
  • Prostředí: Install the UPS in a well-ventilated area, free from excessive dust, humidity, and corrosive substances. Avoid direct sunlight and heat sources.
  • Základy: Ensure the UPS is properly grounded to prevent electrical shock.
  • Nouzové vypnutí (EPO): Familiarize yourself with the EPO function for immediate shutdown in emergencies.

3. Konec produktuview

3.1 Klíčové vlastnosti

  • Double Conversion Online Technology: Provides continuous, clean power by converting incoming AC to DC and then back to AC, isolating connected equipment from utility power fluctuations.
  • Výstup čisté sinusové vlny: Ensures compatibility with all types of electronic loads, preventing distortion and electrical noise.
  • Nízká hladina hluku: Operates at less than 40 dB, suitable for office environments.
  • Správa softwaru: Includes specialized software for remote monitoring, scheduled power on/off, battery tests, and complete UPS configuration.
  • Komunikační porty: Equipped with RS232, HID USB, and EPO ports. An optional SNMP card slot is available for advanced network monitoring.
  • Vnitřní baterie: Features 4 x 12V7Ah sealed lead-acid batteries for reliable backup power.

3.2 Připojení zadního panelu

NJOY Echo Pro 2000 UPS rear panel with labeled ports

Figure 3.1: Rear panel of the NJOY Echo Pro 2000 UPS, showing various connection ports.

  1. Rozhraní RS232: For serial communication with a computer or network device.
  2. Schuko Outlets (x4): Output receptacles for connecting protected equipment.
  3. Vstupní jistič: Overcurrent protection for the UPS input.
  4. Ventilátor: Cooling fan for internal components.
  5. SNMP Slot: Expansion slot for an optional SNMP card (not included) for network management.
  6. EPO (Nouzové vypnutí): Konektor pro dálkové nouzové vypnutí.
  7. USB rozhraní: Pro komunikaci s počítačem přes USB.
  8. AC vstup: Power input connector for the UPS.

4. Nastavení

Follow these steps to properly set up your NJOY Echo Pro 2000 UPS:

  1. Rozbalení: Carefully unpack the UPS and inspect it for any shipping damage. Report any damage to your dealer.
  2. Umístění: Place the UPS in a clean, dry, and well-ventilated indoor environment. Ensure adequate clearance around the unit for proper airflow. Avoid placing it near heat sources or in direct sunlight.
  3. Počáteční nabíjení: Connect the UPS to a grounded AC power outlet using the provided power cord. Allow the UPS to charge for at least 8 hours before connecting any equipment to ensure optimal battery performance. The LCD display will indicate charging status.
  4. Spojovací zařízení: Once the UPS is fully charged, connect your critical equipment (servers, computers, monitors, etc.) to the Schuko output receptacles on the rear panel. Do not connect surge suppressors or power strips to the UPS output.
  5. Nastavení komunikace: For monitoring and management, connect the UPS to your computer using the provided USB or RS232 cable. Install the specialized management software (refer to Section 5.2).
  6. EPO Connection (Optional): If using the Emergency Power Off function, connect the EPO cable to the designated port.

5. Návod k obsluze

5.1 Zapnutí/vypnutí

  • Zapnutí: Press and hold the 'ON' button on the front panel for approximately 2 seconds until the UPS powers on and the LCD display illuminates.
  • Vypnutí: Press and hold the 'OFF' button for approximately 2 seconds. The UPS will shut down, and the display will turn off.

5.2 LCD displej a ovládací tlačítka

The front panel LCD provides real-time status information. Use the 'ENTER' and 'ESC' buttons to navigate through the display menus and view various parameters such as input/output voltage, battery level, load level, and operating mode.

5.3 Správa softwaru

The included software allows for comprehensive monitoring and control of the UPS. Install the software on a connected computer to:

  • Monitor real-time UPS status and parameters.
  • Schedule automatic power on/off and battery tests.
  • Configure UPS settings and alarm thresholds.
  • Receive notifications for power events.
  • Perform safe shutdown of connected computer systems during extended power outages.
Screenshot of the UPS management software interface

Obrázek 5.1: Přample of the UPS management software interface, showing status and configuration options.

6. Údržba

Pravidelná údržba zajišťuje dlouhou životnost a optimální výkon vaší UPS.

  • Péče o baterie: The UPS contains sealed lead-acid batteries. These batteries typically last 3-5 years under normal operating conditions. Replace batteries when their runtime significantly decreases. Only use replacement batteries of the same type and rating (4 x 12V7Ah). Battery replacement should be performed by qualified service personnel.
  • Čištění: Keep the UPS clean and free of dust. Use a dry cloth to wipe the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are clear of obstructions.
  • Podmínky prostředí: Maintain the UPS within the recommended operating temperature and humidity ranges to prolong its lifespan.
  • Autotest: Periodically perform a battery self-test using the management software or front panel controls to assess battery health.

7. Řešení problémů

This section provides solutions to common issues you might encounter with your UPS. If the problem persists, contact technical support.

Problém Možná příčina Řešení
UPS se nezapne No AC input; Low battery; UPS fault Check AC power cord connection; Allow UPS to charge; Contact support if fault persists.
UPS nepřetržitě pípá Overload; Low battery; UPS fault Reduce connected load; Allow UPS to charge; Check LCD for error codes.
Krátká doba zálohování Overload; Batteries need replacement Reduce connected load; Perform battery test and replace if necessary.
Software not communicating with UPS Nesprávný kabel; Problém s ovladačem; Nastavení softwaru Ensure correct USB/RS232 cable is used; Reinstall drivers; Check software communication settings.

8. Specifikace

Funkce Specifikace
ZnačkaÚŽASNOST
Číslo modeluUPOL-OL200EP-CG01B_SIL
Typ produktuTower UPS
TechnologieOnline (VFI) Double Conversion
Výkonová kapacita2000 VA / 1600 W
Výstupní účiník0.8
Vstup Nominální Voltage230 V AC
Vstupní objemtage Dosah80 - 300 V AC
Vstupní frekvence50 Hz / 60 Hz (auto-sensing)
Jmenovitý výkon Voltage208/220/230/240 V AC
Výstupní průběhČistá sinusová vlna
Vývody4x Schuko
Baterie4 x 12V7Ah Sealed Lead-Acid (internal)
Účinnostaž 96 %
ZobrazitLCD
Komunikační portyRS232, HID USB, EPO, SNMP Slot (optional card)
Úroveň hluku<40 dB
Kompatibilní zařízeníGaming Computers, DVRs, Video Surveillance Systems, WiFi/ADSL/Fiber Modems, Monitors, Printers, TVs, NAS, Servers
UPS runtime chart showing power vs. duration

Figure 8.1: Runtime autonomy chart for the NJOY Echo Pro 2000 UPS. This chart illustrates the approximate backup duration at different load levels. For example, at 1600W (100% load), the runtime is approximately 1 minute, while at 400W (25% load), it is approximately 17 minutes.

9. Informace o záruce

For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official NJOY webUschovejte si doklad o koupi pro případ reklamace.

10. Podpora

If you require technical assistance or have questions regarding your NJOY Echo Pro 2000 UPS, please contact NJOY customer support through their official webwebu nebo kontaktních informací uvedených v dokumentaci k produktu.