1. Úvod
This manual provides essential information for the safe and effective installation, operation, and maintenance of your DIHOOL AC DC Circuit Breaker with IP65 Din Box. This device is designed to provide protection for various electrical systems, including photovoltaic solar panel arrays, solar charge controllers, batteries, power inverters, household lighting, and small motor control applications.
The circuit breaker features a robust IP65-rated enclosure, multiple protection mechanisms, and a non-polarized design for simplified wiring. Please read this manual thoroughly before installation and use.

Obrázek 1.1: Konecview of the DIHOOL Circuit Breaker Box, highlighting overload protection, short circuit protection, and electrical isolation.
2. Bezpečnostní informace
VAROVÁNÍ: Elektrické práce by měl provádět pouze kvalifikovaný personál. Nedodržení těchto bezpečnostních pokynů může vést k úrazu elektrickým proudem, požáru nebo vážnému zranění.
- Před instalací nebo servisem jističe vždy odpojte napájení.
- Ujistěte se, že veškeré zapojení splňuje místní a národní elektrotechnické předpisy.
- Nepřekračujte stanovený objemtaga jmenovité proudy zařízení.
- Verify all connections are secure to prevent loose contacts and overheating.
- Keep the enclosure lid closed and sealed to maintain IP65 protection.
- Do not modify the circuit breaker or its enclosure.
3. Vlastnosti produktu
- IP65 Circuit Breaker DIN Rail Box: Constructed from durable PC+ABS material, offering high impact resistance, high heat resistance, and excellent dimensional stability. It is V1 grade flame retardant, resistant to acid, alkali, solvents, and UV radiation. The transparent cover allows for easy visual inspection of the circuit breaker status. This 3-way box provides ample space for convenient wiring and installation.
- Miniaturní jistič: Features a built-in arc squelching magnet for high arc extinction, a flame-retardant enclosure, silver contacts, and pure copper coils to ensure high quality and reliable performance.
- Vícenásobná ochrana: Provides isolation, short circuit protection (for 48-400V DC or 90-400V AC systems), and overload protection with a C-curve trip characteristic and thermal magnetic trip mechanism. It is suitable for systems ranging from 12V-400V DC or 90-400V AC.
- Non-Polarized Design: The circuit breaker does not require polarity distinction, allowing for connection in either direction. This simplifies installation and reduces wiring errors, making it ideal for applications where polarity may reverse, such as reversible motors, battery charge/discharge switching, bidirectional current protection (EV charging/discharging circuits, solar power systems), and industrial reversible drive systems.
- Wide Cable Range: Includes two types of IP68 cable glands. One-hole glands are suitable for 2-conductor wires ranging from 9-16mm (0.35-0.63 inches). Two-hole glands are suitable for wires ranging from 4-6mm (0.15-0.23 inches).

Image 3.1: High-quality housing features, including flame retardancy, UV resistance, and IP65 waterproof rating.

Image 3.2: Comparison of IP44 and IP65 waterproof ratings, showing the enhanced dust-proof and splash-proof design.

Image 3.3: Details on the upgraded shell material (ABS+PC+Flame retardant) for improved outdoor use, UV-proof, impact resistance, and longer service life.

Image 3.4: Illustration of the electromagnetic arc quenching mechanism with built-in magnets for accelerated arc extinction.

Obrázek 3.5: Detailní view of the circuit breaker's internal components, including the arc extinction chamber, electromagnetic trip, silver alloy contacts, and tunnel type terminal.
4. Obsah balení
Ověřte, zda jsou v balení přítomny všechny položky:
- 1x DIHOOL AC DC Circuit Breaker with IP65 Din Box (10 Amp)
- 2x montážní šrouby
- 4x Crimp Ferrules for wiring
- 4x Rubber Plugs for screw holes
- 1x Insulating Tape
- Cable Glands (quantity and type as per order)

Image 4.1: Visual representation of the package contents, including the circuit breaker box, cable glands, screws, crimp ferrules, and insulating tape. Also shows box dimensions.
5. Specifikace
| Atribut | Hodnota |
|---|---|
| Značka | DIHOOL |
| Číslo modelu | HT3-10A |
| Proud AC adaptéru | 10 Amps |
| Materiál | Akrylonitril-butadien-styren (ABS), polykarbonát (PC) |
| Počet obvodů | 2 |
| Typ fáze | Jednofázový |
| svtage | 12V - 400V (DC), 90V - 400V (AC) |
| Wattage | 120 watts (for 12V system) |
| Hmotnost položky | 1.12 libry |
| Rozměry produktu | 3.86 x 3.15 x 9.77 palce |
| Typ montáže | Plug-In Mount |
| UV Proof Level | High (5 stars) |

Image 5.1: Comparison of installation space between HT3-DZ47X (larger) and HT2-DZ47X (smaller) models, highlighting dimensions and material differences.
6. Nastavení a instalace
Follow these steps for proper installation of your circuit breaker box:
- Připravte montážní povrch: Choose a suitable location for mounting. For outdoor installations, vertical mounting is crucial to prevent water ingress through panel gaps.
- Vyvrtejte montážní otvory: Open the lid of the waterproof box. Use the box as a template to mark the screw hole positions on the wall. Drill holes with an appropriate drill bit and insert expansion tubes if necessary.
- Namontujte krabici: Fix the box to the wall using the provided screws.
- Install Cable Glands: Insert the waterproof cable glands into the designated holes on the box. Screw the lock nut tightly from the inside.
- Kabelová připojení:
- Strip the insulation from your cables to the appropriate length.
- Insert the cable through the gland and connect it to the circuit breaker terminals. Use the provided crimp ferrules to ensure tight and secure connections.
- If the cable is too thin for the gland, use the provided insulating tape to seal the cable with the gland for a waterproof seal.
- Refer to the wiring diagrams below for AC and DC system connections.
- Zajistěte víko: After wiring, cover the circuit breaker box with its lid and fix it with the remaining screws. Insert the rubber plugs into the screw holes on the box cover to prevent rust and enhance waterproofing.

Image 6.1: Step-by-step installation method for the 3-way waterproof box, showing wire connection, wall drilling, and lid covering.

Image 6.2: Detailed assembly instructions for the waterproof cable gland, showing insertion, tightening, cable insertion, and sealing.

Image 6.3: Close-up of screw installation and the waterproof rubber ring, along with cable gland details for 2-10mm² cables.

Image 6.4: Important note regarding screw installation: use a manual screwdriver to avoid stripping the plastic lid.

Image 6.5: Illustration emphasizing vertical mounting for outdoor use to prevent water ingress, contrasting with incorrect horizontal mounting.
Schémata zapojení
The non-polarized design allows for flexible wiring. Below are typical wiring configurations for AC and DC systems.

Image 6.6: Wiring diagrams for connecting the circuit breaker in both AC (90-400V) and DC (12-400V) systems, showing connections to solar panels, MPPT controller, battery, and load.
7. Návod k obsluze
The DIHOOL AC DC Circuit Breaker operates as a standard miniature circuit breaker. The toggle switch on the breaker indicates its status:
- NA: Power is flowing through the circuit.
- OFF: Power to the circuit is interrupted.
- ZAPÁKL: The breaker has automatically switched to the OFF position due to an overload or short circuit.
To restore power after a trip, first identify and resolve the cause of the trip. Then, firmly push the toggle switch to the OFF position before pushing it back to the ON position.
Due to its non-polarized nature, the input and output connections are reversible. This means the left/right polarity sequence and the cable in/out direction can be reversed without affecting functionality, simplifying installation in various setups.

Image 7.1: Illustration demonstrating the non-polar nature of the circuit breaker, allowing for both top-in/bottom-out and bottom-in/top-out wiring configurations.
8. Údržba
Regular maintenance helps ensure the longevity and reliable operation of your circuit breaker:
- Vizuální kontrola: Periodically inspect the circuit breaker box for any signs of physical damage, cracks, or discoloration. Check the transparent lid for clarity.
- Kontrola připojení: Ensure all wire connections remain tight and secure. Loose connections can lead to overheating and potential hazards.
- Čistota: Keep the exterior of the box clean and free from dust, dirt, and moisture. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Integrita těsnění: Verify that the cable glands and rubber plugs for the screw holes are properly seated and sealed to maintain the IP65 waterproof rating.
9. Řešení problémů
If you encounter issues with your circuit breaker, consider the following common troubleshooting steps:
- Časté vypínání jističe:
- Přetížení: The connected load may be drawing too much current. Reduce the load or ensure the circuit capacity matches the demand.
- Zkrat: A direct connection between live and neutral/ground wires. Inspect wiring for damage, loose connections, or faulty appliances.
- Vadný spotřebič: Disconnect appliances one by one to identify a malfunctioning device.
- Žádné napájení obvodu:
- Breaker in OFF position: Check if the breaker is simply switched off.
- Uvolněná připojení: Inspect all wiring connections within the box and at the load for tightness.
- Problém s napájením proti proudu: Check the main power supply or any upstream breakers/fuses.
- Water Inside Box:
- Improper Gland Installation: Ensure cable glands are tightened correctly around the cables.
- Missing Rubber Plugs: Verify all screw holes on the lid have their rubber plugs inserted.
- Horizontal Mounting (Outdoor): If mounted horizontally outdoors, water can ingress. Re-mount vertically.
- Damaged Enclosure: Inspect the box for cracks or damage that could compromise the seal.
If the problem persists after performing these checks, consult a qualified electrician.
10. Informace o záruce
This DIHOOL AC DC Circuit Breaker comes with a 2-letá záruka from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, unauthorized modifications, or acts of nature.
Uschovejte si prosím doklad o koupi pro uplatnění záruky.
11. Podpora
For technical assistance, product inquiries, or warranty claims, please contact DIHOOL customer support through the retailer where the product was purchased or visit the official DIHOOL webstránky pro kontaktní informace.
When contacting support, please have your product model number (HT3-10A) and purchase details readily available.