OWON SDS1102

OWON SDS1102 Digital Oscilloscope User Manual

Model: SDS1102 | Brand: OWON

1. Úvod

The OWON SDS1102 is a 2-channel digital storage oscilloscope designed for a wide range of electronic measurement and analysis tasks. It features a 100 MHz bandwidth, a 1 GSa/s real-time sampling rate, and a clear 7-inch TFT-LCD display. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your device, ensuring optimal performance and longevity.

OWON SDS1102 Digital Oscilloscope front view with screen displaying waveforms and control panel.

Figure 1: OWON SDS1102 Digital Oscilloscope

2. Bezpečnostní informace

Please read and understand all safety instructions before operating the device. Failure to comply with these instructions may result in electric shock, fire, or damage to the product.

  • Používejte pouze napájecí kabel dodaný se zařízením.
  • Ensure the device is properly grounded to prevent electric shock.
  • Neprovozujte zařízení ve vlhku nebo damp podmínky.
  • Avoid exposing the device to direct sunlight or high temperatures.
  • Neotevírejte zařízení casing; veškerý servis svěřte kvalifikovanému personálu.
  • Verify probe attenuation settings match the oscilloscope's input settings.

3. Obsah balení

Ověřte, zda jsou v balení obsaženy všechny níže uvedené položky:

  • OWON SDS1102 Digital Oscilloscope
  • Napájecí kabel
  • CD-ROM (containing software and documentation)
  • USB kabel
  • Osciloskopické sondy (2 kusy)
  • Probe Adjustment Tool (screwdriver)
  • Uživatelská příručka (tento dokument)

4. Konec produktuview

The SDS1102 is designed for efficiency and accuracy in various applications, from electronic circuit debugging to automotive maintenance.

Klíčové vlastnosti:

  • HD LCD obrazovka: A 7-inch color TFT-LCD with 65535 colors and 800 x 480 pixel resolution provides clear and concise waveform readings. It supports four automatic cursor modes for precise voltage and time difference measurements.
  • Vysoká Sampsazba ling: Equipped with a 1 GSa/s sampling rate, the device allows for detailed waveform capture and analysis. It includes single waveform recording and playback, and supports plug-and-play USB storage devices.
  • Powerful System: Features an auto-range function and supports horizontal, vertical, single/multi-waveform tracking. Probe attenuation settings include 1x, 10x, 100x, and 1000x. It offers 30 types of automatic measurement functions and supports LABVIEW communication for secondary development.
  • Přenosnost: With ultra-thin body design (301 x 152 x 70 mm) and a weight of 1.1 kg, the oscilloscope is highly portable, saving desktop space and operating quietly.
OWON SDS1102 Oscilloscope highlighting 1GS/s Sample rate, 2-Channel, 10K Record Length, 100 MHz Bandwidth, and 7 inch high resolution LCD.

Figure 2: Key features of the SDS1102 Oscilloscope

Diagram showing the dimensions (301x152x70mm) and weight (1.1 kg) of the ultra-thin OWON SDS1102 Oscilloscope.

Figure 3: Compact design and dimensions for portability

Four images depicting various applications of the oscilloscope: circuit testing, design and manufacture, education and training, and automobile maintenance.

Figure 4: Diverse applications of the SDS1102 Oscilloscope

5. Nastavení

5.1 Počáteční zapnutí

  1. Connect the power cord to the oscilloscope and a suitable power outlet.
  2. Stisknutím tlačítka napájení zapněte zařízení.
  3. The 7-inch TFT-LCD display will illuminate, showing the OWON logo and then the main waveform interface.

5.2 Kalibrace sondy

Before taking measurements, it is crucial to calibrate the oscilloscope probes for accurate readings. This process compensates for any slight variations in the probes as supplied.

  1. Connect a probe to one of the BNC input connectors (e.g., CH1).
  2. Ensure the probe's attenuation switch (usually on the probe body) is set to 10x.
  3. Connect the probe tip to the test point, which is a small metal loop located on the bottom right of the oscilloscope's front panel.
  4. Attach the black grounding alligator clip of the probe to the lower metal loop, which serves as the ground test point.
  5. Stiskněte tlačítko Automatické nastavení button on the oscilloscope. The device will automatically adjust settings to display the test signal. The test point outputs a 1 kHz, 5V square wave.
  6. Observe the waveform on the screen. If it does not appear as a perfect square wave (e.g., rounded corners or overshoot), use the supplied probe adjustment tool (small screwdriver).
  7. Carefully insert the screwdriver into the compensation screw on the BNC connector of the probe and adjust it until the displayed square wave is clean and flat on top and bottom, with sharp corners. A slight turn (approximately 1/8th) may be sufficient.
  8. Repeat this process for all probes you intend to use.
A hand using an oscilloscope probe to test a circuit board, with the OWON SDS1102 Oscilloscope in the background.

Figure 5: Oscilloscope probe connected to a circuit for testing

6. Návod k obsluze

6.1 Základní zobrazení křivky

  • Připojte sondu k testovanému obvodu.
  • Upravte Vertical Scale (VOLTS/DIV) a Horizontal Scale (SEC/DIV) knobs to get a stable and viewable waveform on the screen.
  • Použijte Pozice knobs to move the waveform vertically or horizontally.
  • Stiskněte tlačítko Automatické nastavení button for automatic waveform optimization.
Oscilloscope screen demonstrating the auto-range function, adjusting the display to fit the input signal.

Figure 6: Auto-range function in action

6.2 Cursor Measurements

The SDS1102 supports four automatic cursor modes for precise measurements.

  1. Stiskněte tlačítko Kurzor tlačítko.
  2. Select the desired cursor type (e.g., Voltage, Time) using the menu options.
  3. Adjust the cursor positions using the multipurpose knob to measure specific points on the waveform.
  4. The measured values (e.g., ◊V, ◊T) will be displayed on the screen.
Oscilloscope screen displaying a waveform with cursor measurements for voltage a časové rozdíly.

Figure 7: Performing cursor measurements

6.3 Automatická měření

The oscilloscope offers 30 types of automatic measurements for quick analysis.

  1. Stiskněte tlačítko Opatření tlačítko.
  2. Navigate through the menu to select the desired automatic measurements (e.g., Frequency, Peak-to-Peak Voltage, RMS).
  3. The selected measurements will be displayed on the screen, updating in real-time.
Oscilloscope screen displaying a comprehensive list of automatic measurements for a waveform, including Min, Max, Peak-to-Peak, Frequency, Period, and more.

Figure 8: Automatic measurement display

6.4 Waveform Recording and Playback

The device allows for recording and replaying single waveforms.

  1. Stiskněte tlačítko Uložit/Vyvolat button (or similar function).
  2. Select the option to record a waveform.
  3. To replay, select the playback option and choose the desired stored waveform.
Oscilloscope screen showing a menu for saving and recalling waveforms, demonstrating the waveform recording and playback function.

Figure 9: Waveform save and recall menu

6.5 USB Connectivity and PC Control

The SDS1102 supports plug-and-play USB storage devices for saving data and configurations. It also allows for remote communication and control via a computer using the USB interface, with support for LABVIEW and SCPI commands.

OWON SDS1102 Oscilloscope connected via USB cable to a laptop, demonstrating SCPI and LabVIEW support for remote control.

Figure 10: USB connection for PC communication and data transfer

7. Údržba

The OWON SDS1102 is designed for continuous, maintenance-free use under normal operating conditions. However, proper care ensures its longevity and performance.

  • Čištění: Use a soft, dry cloth to clean the exterior of the oscilloscope. For stubborn dirt, a slightly damp Lze použít hadřík s jemným čisticím prostředkem, ale dbejte na to, aby se do zařízení nedostala žádná tekutina. Nepoužívejte abrazivní čisticí prostředky ani rozpouštědla.
  • Skladování: When not in use, store the oscilloscope in a clean, dry environment, away from extreme temperatures and humidity.
  • Péče o sondu: S sondami zacházejte opatrně. Neohýbejte ani nenamáhejte kabely. Udržujte hroty sond čisté.
  • Vnitřní údržba: The device does not require user-performed internal maintenance. Do not attempt to open the casing, protože by to mohlo vést ke ztrátě záruky a vystavení vás riziku úrazu elektrickým proudem.

8. Řešení problémů

If you encounter issues with your OWON SDS1102, refer to the following common troubleshooting steps:

Problém Možná příčina Řešení
Zařízení se nezapne. Power cord not connected; power outlet faulty; device fault. Check power cord connection. Test power outlet with another device. If problem persists, contact support.
Nezobrazuje se žádný průběh. Probe not connected; probe faulty; input signal too small/large; incorrect vertical/horizontal settings. Ensure probes are securely connected. Check probe functionality. Adjust VOLTS/DIV and SEC/DIV. Use Autoset.
Waveform is distorted or noisy. Uncalibrated probe; poor grounding; external interference. Perform probe calibration (Section 5.2). Ensure proper grounding. Minimize external electromagnetic interference.
USB storage not recognized. USB device format incompatible; faulty USB device/port. Ensure USB device is formatted correctly (e.g., FAT32). Try a different USB device or port.

For issues not covered here, please refer to the full manual on the provided CD-ROM or contact OWON customer support.

9. Specifikace

Funkce Specifikace
Výrobce OWON
Číslo modelu OWON-SDS1102
Rozměry (D x Š x V) 30.1 x 15.2 x 7 cm
Hmotnost 1.67 kg
Zobrazit 7-inch Color TFT-LCD, 800 x 480 pixels
Kanály 2
Šířka pásma 100 MHz
Sample Rate 1 GSA/s
Délka záznamu 10K points
Čas vzestupu ≤1.7 ns
Útlum sondy 1x, 10x, 100x, 1000x
Automatic Measurements 30 typů
Konektivita USB (for storage, PC communication)
Softwarová podpora LABORATOŘVIEW, SCPI
Baterie jsou součástí dodávky Žádný
Datum první dostupnosti 23. června 2022
Banner displaying key specifications: 100MHz, 7 inch LCD, 2-Channel, 1GS/s, Record length 10K, less than or equal to 1.7ns Rise time.

Figure 11: Summary of key technical specifications

10. Záruka a podpora

OWON products are designed for reliability and performance. For warranty information, please refer to the documentation included on the CD-ROM or visit the official OWON website. Information regarding the availability of spare parts is currently unavailable.

For technical support, product inquiries, or service requests, please contact OWON customer service through their official channels. Keep your purchase receipt and product model number (OWON-SDS1102) handy when contacting support.