1. Úvod
This manual provides essential information for the proper use and maintenance of your YIHUA 907P Wire-Nib Type Replacement Pyrography Pen. This pen is designed as a replacement component for specific YIHUA 939 series wood burning pyrography stations. Please read these instructions carefully before installation and operation to ensure safe and effective use.

Obrázek 1.1: The YIHUA 907P Wire-Nib Type Replacement Pyrography Pen. This image displays the complete pen unit, featuring a comfortable foam grip, the nib holder, and the connecting cable with its plug.
2. Kompatibilita
The YIHUA 907P Wire-Nib Type Replacement Pyrography Pen is specifically designed for use with the following YIHUA Wood Burning Pyrography Stations:
- YIHUA 939 II
- YIHUA 939D-II
- YIHUA 939-III
- YIHUA 939D-V
- YIHUA 939D-VI
- YIHUA 939D-VII
Důležitá poznámka: This pen is not compatible with other models. Please verify your station model before attempting to connect the 907P pen. Using an incompatible pen may result in damage to the pen or the pyrography station.

Obrázek 2.1: Detailní záběr view of the YIHUA 907P pen's connector. This image highlights the specific three-pin connector type required for compatibility with the listed YIHUA pyrography stations.
3. Setup and Nib Installation
Follow these steps to safely install or replace the pyrography nibs in your YIHUA 907P pen:
- Ujistěte se, že je napájení vypnuto: Always ensure your pyrography station is turned off and unplugged before handling the pen or nibs. Allow the pen to cool completely if it has been in use.
- Unscrew Nib Holder: Gently unscrew the black plastic cap at the tip of the pen to expose the nib terminals.
- Loosen Terminal Screws: Use a small screwdriver to slightly loosen the two screws on the metal terminals where the nib will be inserted. Do not remove the screws completely.
- Insert Nib: Carefully insert the ends of your desired wire-nib into the two terminal holes. Ensure the nib is seated firmly and evenly.
- Utáhněte šrouby svorek: Tighten the two screws to secure the nib in place. Ensure the connection is firm but do not overtighten, as this can damage the nib or terminals.
- Replace Nib Holder Cap: Screw the black plastic cap back onto the pen tip until it is snug.
- Connect Pen to Station: Align the pen's connector with the corresponding port on your YIHUA pyrography station and push firmly until it clicks into place.

Obrázek 3.1: Visual guide for installing a wire nib. This composite image illustrates the steps: unscrewing the cap, loosening screws, inserting the nib, tightening screws, and replacing the cap.

Obrázek 3.2: Detailní view of the nib holder mechanism. This image provides a clear look at the two terminal screws and the slots where the wire nib is inserted.
4. Návod k obsluze
Once the pen is properly connected to your compatible YIHUA pyrography station and a nib is installed, you can begin operation:
- Zapnutí: Turn on your YIHUA pyrography station.
- Nastavit teplotu: Adjust the temperature setting on your station according to the type of wood or material you are working with and the desired effect. Refer to your station's manual for specific temperature guidance.
- Povolit vytápění: Wait for the nib to reach the set temperature. This usually takes a few moments.
- Begin Pyrography: Hold the pen comfortably and apply the heated nib to your material. Practice on scrap material first to get a feel for the temperature and pressure required.
- Vypnout: When finished, turn off your pyrography station and allow the pen and nib to cool completely before disconnecting or changing nibs.

Obrázek 4.1: The YIHUA 907P pen being used for wood burning. This image shows a hand holding the pen to create a detailed design on a piece of wood, demonstrating typical usage.
5. Údržba
Proper maintenance ensures the longevity and performance of your pyrography pen:
- Nib Cleaning: Regularly clean the carbon buildup from your nibs using fine-grit sandpaper or a specialized cleaning brush while the nib is still warm (but not glowing hot). Always wear appropriate protective gear.
- Pen Body Cleaning: Wipe the pen body with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Skladování: Store the pen in a dry, safe place away from dust and moisture when not in use. Ensure the nib is protected from bending or damage.
- Kontrola kabelů: Periodically inspect the cable for any signs of wear, cuts, or damage. Discontinue use if any damage is observed and replace the pen.
6. Řešení problémů
If you encounter issues with your YIHUA 907P pen, consider the following:
- Pen Not Heating:
- Ensure the pen is securely connected to the pyrography station.
- Verify that the nibs are correctly installed and the terminal screws are tightened. Loose connections can prevent heating.
- Check if the pyrography station is powered on and set to an appropriate temperature.
- Inspect the nib for breakage or excessive wear. Replace if necessary.
- Pen Overheating / Cord Getting Hot:
- Immediately disconnect the pen from the station.
- This could indicate an internal short circuit or a faulty component. Do not attempt to repair. Contact support for assistance.
- Nekonzistentní vytápění:
- Check for loose nib connections.
- Ensure the nibs are clean and free of carbon buildup.
- Verify the station's temperature stability.

Obrázek 6.1: View of the internal wiring near the nib holder. This image shows the connection points for the heating element, which are crucial for proper function. Any visible damage here may indicate a fault.
7. Specifikace
| Funkce | Detail |
|---|---|
| Model | YIHUA 907P |
| Typ | Wire-Nib Replacement Pyrography Pen |
| Kompatibilní stanice | YIHUA 939 II, 939D-II, 939-III, 939D-V, 939D-VI, 939D-VII |
| Zdroj napájení | Corded Electric (via compatible station) |
| Speciální funkce | Adjustable Temperature (controlled by station) |
| Materiál rukojeti | Plastic with foam grip |
| Typ hořáku | Keramický |
| Délka položky | Approximately 15 Centimeters |
| Hmotnost položky | Přibližně 0.14 kilogramu (5 unce) |
8. Podpora
For further assistance, compatibility verification, or technical support regarding your YIHUA 907P Wire-Nib Type Replacement Pyrography Pen, please contact YIHUA customer service through the Buyer-Seller Messaging System on the platform where you purchased the product. Provide your product model and a detailed description of your inquiry for prompt support.