The 01 MH-13001 LCD Digital Humidity Controller is a high-precision device designed to accurately monitor and control environmental humidity. Its large, clear LCD display ensures easy readability and operation. Constructed from durable, high-quality plastic, this controller is built for longevity and reliable performance. It is compact and lightweight, making it highly portable and an essential tool for various applications, particularly in environments requiring precise humidity management such as breeding farms.

01 MH-13001 LCD Digital Humidity Controller

Image: The 01 MH-13001 LCD Digital Humidity Controller, showing its compact design and clear digital display.

Klíčové vlastnosti

  • Velký LCD displej: Enhances readability and simplifies operation.
  • Vysoce kvalitní konstrukce: Made from durable materials for extended lifespan.
  • High-Precision Humidity Control: Ensures accurate environmental humidity management.
  • Kompaktní a přenosné: Small size and light weight make it easy to transport and install.
  • Všestranná aplikace: Suitable for equipment and settings requiring humidification or dehumidification, such as breeding farms.

Nastavení a instalace

Before installation, ensure the power supply is disconnected. The controller operates on AC 220V. Follow the wiring diagram carefully to connect the power, load, and sensor.

Obsah balení:

  • 1 x Humidity Controller
  • 1 x senzor vlhkosti
  • 1 x Návod k obsluze (tento dokument)

Pokyny pro zapojení:

Refer to the diagram below for proper wiring connections. Ensure all connections are secure to prevent electrical hazards.

Wiring Diagram for MH-13001 Humidity Controller

Image: Wiring diagram illustrating connections for power, load, and the humidity sensor. Terminals 1 and 2 are for the load, 3 and 4 for power input, and 5, 6, 7 for the sensor.

Humidity Sensor with Cable

Image: The high-quality humidity sensor with its connecting cable, designed for durability and long service life.

Návod k obsluze

The controller features a clear LCD display and intuitive buttons for setting and monitoring humidity levels.

MH-13001 Controller Display and Buttons

Obrázek: Detail view of the controller's LCD display and control buttons. Labels indicate 'D' for Dehumidify, 'H' for Humidification, '%RH' for Humidity display, 'S' for Setting, 'R' for Reset, and Up/Down arrows for adjustment.

Funkce tlačítek:

  • S (Setting) Button: Press to enter setting mode. Use Up/Down arrows to adjust the desired humidity set point. Press 'S' again to confirm and exit.
  • Tlačítko šipka nahoru: Increases the humidity set point or navigates through menu options.
  • Tlačítko šipka dolů: Decreases the humidity set point or navigates through menu options.
  • Tlačítko R (Reset): Resets the controller to default settings or clears alarms.
  • D (Dehumidify) Indicator: Illuminates when the controller is actively dehumidifying.
  • H (Humidification) Indicator: Illuminates when the controller is actively humidifying.

The large LCD displays the current humidity percentage (%RH). The controller automatically activates humidification or dehumidification equipment based on the set humidity range.

Údržba

To ensure optimal performance and longevity of your humidity controller, follow these general maintenance guidelines:

  • Čištění: Periodically wipe the exterior of the controller with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Péče o senzor: Keep the humidity sensor clean and free from dust or debris. Avoid exposing the sensor to extreme temperatures or direct moisture beyond its operating range.
  • Větrání: Ensure the controller's ventilation slots are not obstructed to prevent overheating.
  • Skladování: Pokud zařízení skladujete delší dobu, uchovávejte jej na chladném a suchém místě mimo dosah přímého slunečního záření a extrémních teplot.

Odstraňování problémů

If you encounter issues with your MH-13001 Humidity Controller, consider the following common troubleshooting steps:

ProblémMožná příčinaŘešení
Ovladač se nezapne.Chybí napájení nebo je zapojení nesprávné.Check power connection (AC 220V). Verify wiring according to the diagram.
Nepřesné údaje o vlhkosti.Sensor is dirty or damaged; sensor cable is loose.Clean the sensor. Ensure the sensor cable is securely connected. Replace sensor if damaged.
Humidification/Dehumidification not activating.Set point is incorrect; load is not connected or faulty.Adjust the humidity set point. Check the connection and functionality of the humidification/dehumidification equipment.
Displej zobrazuje chybový kód.Internal error or sensor issue.Try resetting the device using the 'R' button. If the error persists, contact customer support.

For issues not covered here, please contact the manufacturer's support.

Specifikace

ParametrHodnota
ModelMH-13001 (0116ap5ozvhw)
MateriálPlast
Pracovní svtageAC 220V 50HZ/60HZ
Spotřeba energie3W
Rozsah měření1% ~ 99% RH
Přesnost zobrazení1% RH
Chyba měření± 3% RH
Přesnost ovládání1% RH
Provozní teplota0 ~ 80 ℃
Rozměry (D x Š x V)Přibližně 8.5 x 7.5 x 3.5 cm (3.3 x 3.0 x 1.4 palce)
HmotnostCca. 235 g (8.3 oz)
Země původuČína
MH-13001 Controller with Dimensions

Image: The MH-13001 controller displaying its approximate dimensions for reference.

Záruka a podpora

Information regarding specific warranty terms and availability of spare parts is not provided in the product details. For warranty claims, technical support, or inquiries about spare parts, please contact the manufacturer directly using the contact information provided with your purchase or on the official brand webmísto.

Software updates are not applicable or information is unavailable for this device.

© 2023 01. Všechna práva vyhrazena.

Tato příručka slouží pouze pro informační účely. Specifikace se mohou změnit bez předchozího upozornění.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.