Circutor M22348.

DHC-96 mVdc Digital Voltmeter Shunt User Manual

Model: M22348. | Brand: Circutor

1. Úvod

The Circutor DHC-96 mVdc Digital Voltmeter Shunt (Model M22348.) is a sophisticated digital instrument panel designed for precise monitoring, regulation, and control of electrical variants and process signals. This device is capable of displaying measured electrical values or proportional values of process signals, making it suitable for a wide range of industrial and climate solar installations.

Mezi klíčové vlastnosti patří:

  • Vysoká přesnost měření.
  • Programmable measurement input.
  • Integrated relay output for control and alarm functions.
  • Universal power supply compatibility (80-270 Vca/cc and 16-36 VCC).
  • Frontal IP 54 protection for enhanced durability.
  • Galvanic insulation between external circuits.
  • Self-configurable decimal point.
  • Designed for panel installation (96 x 49 mm).
Circutor DHC-96 mVdc Digital Voltmeter Shunt with red digital display showing '0.000 A' and control buttons below.

Obrázek 1: Přední strana view of the Circutor DHC-96 mVdc Digital Voltmeter Shunt, showing its digital display and control buttons.

2. Nastavení a instalace

Proper installation is crucial for the optimal performance and longevity of your DHC-96 device. Ensure all power sources are disconnected before proceeding with installation.

2.1 Montáž do panelu

  • Prepare a panel cutout with dimensions of 96 x 49 mm.
  • Insert the DHC-96 unit into the cutout from the front.
  • Secure the unit using the provided mounting clips or brackets from the rear of the panel. Ensure a snug fit to maintain the IP 54 frontal protection rating.

2.2 Připojení napájení

The DHC-96 supports a universal power supply. Connect the power source to the designated terminals on the rear of the unit.

  • For AC/DC power, connect to 80-270 Vca/cc terminals.
  • For DC power, connect to 16-36 VCC terminals.
  • Ensure correct polarity for DC connections.

2.3 Measurement Input Connection

Connect the signal source to the programmable measurement input terminals. Refer to the wiring diagram provided with your specific model for detailed connection points.

  • Za svtage measurements, connect the voltage zdroj.
  • For current measurements, connect through a shunt or current transformer as appropriate for your application.
  • Ensure galvanic insulation between external circuits is maintained.

2.4 Připojení reléového výstupu

The DHC-96 features two output relays for control and alarm functions. Connect these relays to your external control systems or alarm indicators as required.

  • Identify the relay output terminals.
  • Wire the relays according to your application's control logic.
  • Configure alarm delays and interlocking settings via the device's menu.

3. Návod k obsluze

Once installed and powered, the DHC-96 is ready for operation. The front panel features a digital display and control buttons for configuration and monitoring.

3.1 Zobrazení nadview

The digital display shows the measured electrical variant (e.g., voltage, current, frequency) or the proportional value of a process signal. The unit automatically adjusts the display based on the configured measurement type.

  • DC Systems: Capable of measuring voltage, current, frequency, and other industrial process variables.
  • AC modely: Perform measurements in True Effective Value (TRMS).
  • Desetinná čárka: The decimal point is self-configurable to suit your measurement precision requirements.

3.2 Funkce tlačítek

The front panel buttons allow for navigation through menus, parameter configuration, and display adjustments. Specific button functions may vary slightly depending on the firmware version.

  • Left/Right Arrows (< / >): Typically used for navigating through menu options or adjusting values.
  • Šipky nahoru/dolů ( / ): Používá se pro zvýšeníasing/dekreasing values or selecting options.
  • Tlačítko Menu/Enter: Used to access the main menu, confirm selections, or save settings.
  • Escape/Back Button: Používá se k opuštění nabídky nebo zrušení operace.

3.3 Configuration and Programming

The DHC-96 allows for programming various parameters to suit specific application needs. This includes setting the measurement input type, configuring alarm thresholds, and defining relay behaviors.

  • Access the configuration menu by pressing the Menu/Enter button.
  • Procházejte možnostmi nabídky pomocí tlačítek se šipkami.
  • Select the desired parameter to modify and adjust its value.
  • Před opuštěním nabídky uložte změny.
  • Refer to the detailed programming guide (if available separately) for advanced configurations.

4. Údržba

The DHC-96 is designed for reliable operation with minimal maintenance. Regular inspection and cleaning will help ensure its continued performance.

  • Čištění: Přední panel pravidelně čistěte měkkým hadříkemamp hadříkem. Nepoužívejte abrazivní čisticí prostředky ani rozpouštědla, protože by mohly poškodit displej neboasing.
  • Inspekce: Regularly inspect the wiring connections for any signs of wear, corrosion, or looseness. Ensure the unit is securely mounted in its panel cutout.
  • Prostředí: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage. The IP 54 frontal protection helps against dust and splashing water, but the unit is not designed for immersion.
  • Žádné díly opravitelné uživatelem: The DHC-96 contains no user-serviceable parts. Do not attempt to open the casing, protože by to vedlo ke ztrátě záruky a mohlo by vás to vystavit nebezpečí úrazu elektrickým proudem.

5. Řešení problémů

If you encounter issues with your DHC-96, refer to the following common troubleshooting steps. For problems not listed here, contact Circutor technical support.

  • Bez displeje/napájení:
    • Check the power supply connections to ensure they are secure and correctly wired.
    • Ověřte, zda je zdroj napájení hlasitýtage is within the specified range (80-270 Vca/cc or 16-36 VCC).
    • Zkontrolujte, zda v napájecím obvodu nejsou vypnuté jističe nebo spálené pojistky.
  • Nesprávné čtení:
    • Ensure the measurement input is correctly connected and the signal source is active.
    • Verify that the device's measurement input type is correctly configured in the settings to match your application (e.g., voltage, current, process signal).
    • Check for any external interference or noise affecting the signal.
    • Confirm the decimal point setting is appropriate for the expected values.
  • Relé se neaktivuje:
    • Check the relay output wiring for proper connection to the external control system.
    • Verify the alarm thresholds and relay logic are correctly configured in the device's settings.
    • Ensure the measured value has exceeded or fallen below the set alarm threshold.
    • Check for any configured alarm delays or interlocking conditions that might prevent immediate activation.

6. Specifikace

AtributHodnota
VýrobceCirkutor
Číslo díluM22348.
Číslo modelu položkyM22348.
Rozměry produktu3.01 x 1.93 x 3.78 palce
Hmotnost položky7 unce
BarvaČerný
StylCir
Zdroj napájeníElektrický
Položka Množství v balení1
Jsou vyžadovány baterie?Žádný
ASINB08WL8FMDB
Datum první dostupnosti15. srpna 2023

7. Záruka a podpora

For detailed warranty information, please refer to the warranty card included with your product or visit the official Circutor webZáruční podmínky se mohou lišit v závislosti na regionu a produktu.

For technical support, service, or inquiries regarding your DHC-96 mVdc Digital Voltmeter Shunt, please contact Circutor customer service or your authorized dealer. Provide your product model number (M22348.) and serial number (if applicable) when seeking support.

You can find more information and contact details on the official Circutor webmísto: www.circutor.com

© 2023 Circutor. All rights reserved. | Model: DHC-96 (M22348.)

Ask a question about this manual