DROK Bidirectional Volt Amp Meter (Model 200536FBA) Instruction Manual

Zavedení

This manual provides detailed instructions for the installation, operation, and maintenance of the DROK Bidirectional Volt Amp Meter, Model 200536FBA. This 7-in-1 monitor is designed to measure DC voltage, current, power, battery capacity, amp-hour, watt-hour, and time, featuring a clear color LCD display and a Hall sensor for non-contact current measurement.

Vlastnosti produktu

  • Měření 7 v 1: Současně zobrazuje hlasitost stejnosměrného proudutage (0-90V), current (0-300A), power, battery capacity, amp-hour, watt-hour, and time on a 1.8-inch LCD color screen.
  • Obousměrný ampérmetr: Detects current flow in both charging and discharging directions without requiring changes to wiring.
  • Komplexní ochranné funkce: Includes Over-Voltage Protection (OVP), Over-Current Protection (OCP), Over-Power Protection (OPP), Low-Voltage Protection (LOP), Over-Charge Protection (OAH), and Over-Time Protection (OFT).
  • Funkce paměti: AH power-off memorized function retains data.
  • Reset and Calibration: Features time and AH reset functions, along with a calibration capability for accurate readings.
  • Ovládání displeje: LCD screen can be switched off automatically or manually.
  • Ovládání výstupu: Connects to a relay (not included) for enabling/disabling output via a control button.

Obsah balení

Ověřte, zda jsou v balení přítomny všechny položky:

  • 1x Charge-Discharge Monitor (Display Unit)
  • 1x Hall Sensor (Current Sensor)
  • 1x 50cm Shielding Wire (for connecting display to sensor)
DROK Bidirectional Volt Amp Meter components including display, Hall sensor, and connecting wires.

Image: The complete package contents, showing the display unit, Hall sensor, and the included shielding wire.

Specifikace

ParametrHodnota
Parametry měřenísvtage, Current, Power, Battery Capacity, Amp-Hour, Watt-Hour, Time
svtage Rozsah měřeníDC 0-90V
Aktuální rozsah měřeníDC 0-300A
svtage Přesnost měření± 2 % ± 5 číslic
Přesnost měření proudu± 3 % ± 5 číslic
Rozlišení displeje0.1A, 0.01V, 0.01AH, 0.01H (1 min)
Míra měření5krát za sekundu
Zobrazit1.8 inch LCD Color Screen
Meter Overall Dimension79 x 43 x 26mm (3.11 x 1.69 x 1.02 palce)
Meter Opening Hole Size76.5 x 39.2 mm (3.01 x 1.54 palce)
Velikost Hallova snímače57 x 32 x 50mm (2.24 x 1.26 x 1.97 inch) (with screw and copper pillars)
Hall Sensor Hole Diameter20 mm (0.79 ​​palců)
Over-Voltage ochrana (OVP)0.01V-90V
Ochrana proti nadproudu (OCP)0.1-100A
Ochrana proti nadměrnému napájení (OPP)0.01W-9.99KW
Nízký objemtage Protection (LOP)0.01V-90V
Over-Charge Protection (OAH)0.01 Ah-9999 Ah
Over-Time Protection (OFT)1 min - 99 hodina 59 min
Dimensions of the DROK display unit and Hall sensor.

Image: Physical dimensions of the display unit and the Hall sensor for installation planning.

Nastavení a instalace

Proper wiring is crucial for accurate measurements and safe operation. The Hall sensor measures current by passing the load wire through its central hole. The display unit requires a power supply (DC 10-60V) and connects to the Hall sensor via the provided shielding wire.

Wiring diagrams for the DROK Bidirectional Volt Amp Meter in three configurations.

Image: Three common wiring configurations for the meter, showing connections to battery, load, and optional relay.

Wiring Configuration 1: Basic Monitoring (Self-Powered)

In this configuration, the meter is powered directly from the battery being monitored. This is suitable for systems where the battery voltage is within the meter's operating range (10-60V).

  1. Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
  2. Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
  3. Předat negativní load wire through the central hole of the Hall sensor. Ensure the direction of current flow through the sensor matches the arrow on the sensor for correct bidirectional readings.
  4. Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
  5. Ensure the jumper cap on the Hall sensor is placed to select the self-powered mode (typically labeled '10-60V' or similar, check the sensor board for exact markings).

Wiring Configuration 2: External Power Supply

Use this configuration when the battery voltage is outside the meter's operating range (e.g., 0-10V or above 60V) or if you prefer a separate power source for the meter.

  1. Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
  2. Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
  3. Předat negativní load wire through the central hole of the Hall sensor.
  4. Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
  5. Connect an external DC power supply (10-60V) to the 'Vext+' and 'Vext-' terminals on the Hall sensor.
  6. Remove the jumper cap from the Hall sensor to enable external power mode.

Wiring Configuration 3: With Relay for Output Control

This setup allows the meter to control an external relay (not included) based on configured protection parameters (e.g., over-current, low-voltagE).

  1. Follow either Configuration 1 or 2 for basic power and measurement connections.
  2. Connect the relay's control terminals to the 'Relay+' and 'Relay-' terminals on the Hall sensor.
  3. Ensure the jumper cap is set correctly for the chosen power mode (self-powered or external).
  4. The meter's output control button can then be used to enable/disable the relay, or the relay can be triggered automatically by protection settings.

Návod k obsluze

The DROK Volt Amp Meter features a user-friendly interface with a color LCD and three control buttons: Up, OK, and Down.

Přední view of the DROK Bidirectional Volt Amp Meter display showing various readings and protection indicators.

Image: The main display interface, showing voltage, current, capacity, power, time, and protection status indicators.

Zobrazit přesview

The 1.8-inch color LCD simultaneously displays:

  • svtage (V): Top left, large font.
  • Proud (A): Below voltage, large font.
  • Battery Capacity (%): Graphical bar and percentage.
  • Amp-Hodina (AH): Accumulated charge/discharge.
  • Watthodina (Wh): Accumulated energy.
  • Výkon (W): Okamžitý výkon.
  • Time (H): Uplynulý čas.
  • Indikátory ochrany: OVP, OPP, OCP, OFT, OAH, LOP (Over-Voltage, Over-Power, Over-Current, Over-Time, Over-Charge, Low-Voltage Ochrana).

Funkce tlačítek

  • Tlačítko šipka nahoru: Navigates upwards through menu options or increases values during settings.
  • Tlačítko šipka dolů: Navigates downwards through menu options or decreases values during settings.
  • Tlačítko OK: Enters menu, confirms selections, or toggles display modes (e.g., battery graph). Press and hold to access certain functions or calibration mode.

Resetting AH and Time

To reset accumulated Amp-Hours (AH) and Time, navigate to the relevant display screen using the arrow buttons. Press and hold the OK button until the values reset. This is useful for monitoring specific charge/discharge cycles.

Postup kalibrace

For optimal accuracy, calibration may be required. Follow these steps carefully:

  1. Vstupte do kalibračního režimu: Když je zařízení vypnuté, stiskněte a podržte tlačítko OK button. While holding OK, switch the power to the device ON. Release the OK button as soon as the display illuminates.
  2. Navigace v kalibračním režimu: V kalibračním režimu stiskněte OK pro přechod z jedné položky nabídky na další. Použijte tlačítko Up a Dolů arrow keys to adjust values.
  3. Kalibrace nulového proudu: Before calibrating current readings, ensure no current is flowing through the Hall sensor. Switch off all loads. Press OK dokud není vybrána možnost „0.0 A“, poté stiskněte tlačítko Dolů šipku jednou pro vynulování aktuální hodnoty.
  4. Positive Current Calibration (+A): To calibrate current in the charging direction, ensure current is flowing from the charging source into your battery. Press OK until the "+A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
  5. Negative Current Calibration (-A): To calibrate current in the discharging direction, ensure current is flowing out of your battery into your loads. Press OK until the "-A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
  6. Uložit nastavení: After completing all calibrations, navigate the cursor to the "Save" option using the OK button. Select "Save" to store your settings.
  7. Ukončit režim kalibrace: To exit calibration mode, simply switch the power to the unit OFF, then ON again.

Ochranné funkce

The meter includes several programmable protection functions to safeguard your system:

  • OVP (Over-Voltage ochrana): Configurable from 0.01V to 90V. Triggers when voltage překračuje stanovený limit.
  • OCP (ochrana proti nadproudu): Configurable from 0.1A to 100A. Triggers when current exceeds the set limit.
  • OPP (ochrana proti přetížení): Configurable from 0.01W to 9.99KW. Triggers when power consumption exceeds the set limit.
  • LOP (Low-Voltage ochrana): Configurable from 0.01V to 90V. Triggers when voltage drops below the set limit.
  • OAH (Over-Charge Protection): Configurable from 0.01AH to 9999AH. Triggers when accumulated charge exceeds the set limit.
  • OFT (Over-Time Protection): Configurable from 1 minute to 99 hours 59 minutes. Triggers when operation time exceeds the set limit.

When a protection limit is reached, the meter can activate an external relay (if connected) to disconnect the load or charging source.

Další funkce

  • AH Power Off Memorized Function: Retains accumulated Amp-Hour data even after power loss.
  • LCD Screen Auto/Manual Switch Off: The display can be configured to turn off automatically after a period of inactivity or can be manually toggled.

Údržba

The DROK Bidirectional Volt Amp Meter is designed for durability and requires minimal maintenance.

  • Čištění: K čištění displeje a c použijte měkký, suchý hadříkasing. Vyhněte se abrazivním čisticím prostředkům nebo rozpouštědlům.
  • Podmínky prostředí: Operate the meter within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, direct sunlight, or moisture.
  • Kontrola elektroinstalace: Pravidelně kontrolujte veškeré kabelové spoje, zda nejsou těsné a zda nevykazují známky opotřebení nebo koroze.

Odstraňování problémů

  • Bez displeje/napájení:
    • Check power connections to the Hall sensor.
    • Zajistěte napájení objtage je v rozsahu 10–60 V.
    • Verify the jumper cap setting for self-powered or external power mode.
    • Check the shielding wire connection between the sensor and the display.
  • Incorrect Current Readings:
    • Ensure the load wire passes correctly through the Hall sensor's central hole.
    • Verify the direction of current flow relative to the arrow on the Hall sensor.
    • Perform a current calibration as described in the "Operating Instructions" section.
    • If monitoring both charging and discharging, ensure only the main battery wire (or the wire carrying the net current) passes through the sensor. Incorrect wiring can lead to inaccurate bidirectional readings.
  • Nepřesný svtage Čtení:
    • Zkontrolovat voltage connections to the Hall sensor.
    • Ujistěte se, že jsou spoje bezpečné a bez koroze.
  • Protection Function Not Triggering:
    • Verify that the protection limits are set correctly in the meter's menu.
    • Ensure the external relay (if used) is correctly wired and functional.

Záruka a podpora

Specific warranty information for the DROK Bidirectional Volt Amp Meter (Model 200536FBA) is not provided in this manual. For warranty claims, technical support, or further assistance, please refer to the product packaging, the seller's website, or contact DROK customer service directly.