1. Úvod
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo CPM150 centrifugal water pump. Please read these instructions carefully before installing or operating the pump. Retain this manual for future reference.
The Pedrollo CPM150 pump is designed for handling clean liquids with minimal sediment. It is suitable for various applications including industrial liquid recycling (cold or hot), filtration processes, water treatment, and general agricultural or domestic use.
2. Bezpečnostní pokyny
Always observe the following safety precautions to prevent personal injury and damage to the pump:
- Ensure the pump is installed by qualified personnel in accordance with local electrical and plumbing codes.
- Před zahájením jakékoli instalace, údržby nebo opravy odpojte napájení.
- Do not operate the pump with flammable, corrosive, or explosive liquids.
- Chraňte čerpadlo před mrazem.
- Ensure proper ventilation around the pump. The ambient temperature should not exceed 40°C.
- Never run the pump dry. This can cause severe damage.
- Během instalace a údržby používejte vhodné osobní ochranné prostředky (OOP).
3. Konec produktuview
The Pedrollo CPM150 is a robust centrifugal pump featuring a cast iron pump body with cataphoresis treatment. The impeller is made of INOX AISI 304 stainless steel, and the motor lantern is aluminum. The pump is designed for continuous service (S1).

Obrázek 1: Explodoval view of the Pedrollo CPM150 pump, showing internal components. Key parts include (1) Pump Body, (2) Impeller, (3) Mechanical Seal, (4) Motor Shaft, (5) Bearings, (6) Motor Casing, (7) Capacitor (for single-phase), and (8) Stator/Rotor Assembly.
The single-phase 220V motor includes integrated thermal protection to safeguard the pump against unexpected starts or overheating. The coupling shaft between the impeller and the electric motor is made of INOX EN 10088-3 - 1.4104. The mechanical seal, composed of carbon, ceramic, and nitrile, ensures a tight seal between the pump body and the electric motor.
4. Specifikace
Below are the key technical specifications for the Pedrollo CPM150 pump:
| Funkce | Specifikace |
|---|---|
| Model | CPM 150 |
| Moc | 0.75 kW |
| svtage | 220 V Single-Phase |
| Frekvence | 50 Hz |
| Průtok (Q) | 0 až 7.2 m³/h |
| Head (HMT) | 29.5 až 15 metrů |
| Rozsah teploty kapaliny | -10°C (with antifreeze) to +90°C |
| Okolní teplota | Not exceeding 40°C |
| Materiál těla čerpadla | Cast Iron with Cataphoresis Treatment |
| Materiál oběžného kola | INOX AISI 304 Stainless Steel |
| Ochrana motoru | IPX4 |
| Třída izolace | F |
| Nepřetržitý servis | S1 |
| Rychlost otáčení | 2900 ot./min |

Obrázek 2: Performance curves for Pedrollo CP series pumps at 50 Hz and 2900 rpm. This graph illustrates the relationship between flow rate (Q) in l/min or m³/h and total head (HMT) in meters or feet for various models, including the CPM150.
5. Instalace a nastavení
Proper installation is crucial for the pump's performance and longevity. It is highly recommended that installation be carried out by a qualified professional.
5.1. Montáž
- Mount the pump on a solid, level, and vibration-free surface.
- Ensure the installation location is dry, well-ventilated, and protected from direct sunlight, rain, and freezing temperatures.
- Zajistěte dostatečný prostor kolem čerpadla pro větrání a přístup pro údržbu.
5.2. Připojení potrubí
- Use pipes of adequate diameter to minimize friction losses.
- Install a foot valve with a strainer on the suction line if the pump is not self-priming or if there's a risk of debris.
- Ensure all connections are airtight to prevent air leaks, which can affect priming and performance.
- Support piping independently to avoid stressing the pump's connections.
- Install isolation valves on both suction and discharge lines for easier maintenance.
5.3. Elektrické připojení
- Ověřte, že napájecí zdroj objtage and frequency match the pump's specifications (220V, 50Hz).
- Připojte čerpadlo k vyhrazenému obvodu chráněnému proudovým chráničem (RCD) a vhodným jističem.
- Zajistěte správné uzemnění čerpadla.
- The single-phase motor includes integrated thermal protection. Do not bypass this safety feature.
5.4. Naplnění čerpadla
Before the first start-up, the pump body must be completely filled with the liquid to be pumped. Open the priming plug (if available) or slowly fill the suction line and pump casing until all air is expelled. Close the plug securely.
6. Provoz
6.1. První spuštění
- Ujistěte se, že je čerpadlo řádně naplněno (viz kapitola 5.4).
- Open any isolation valves on the suction and discharge lines.
- Zapněte napájení čerpadla.
- Monitor the pump for unusual noises or vibrations. If any occur, switch off immediately and investigate.
- Check for leaks at connections.
6.2. Normální provoz
- The pump is designed for continuous operation within its specified performance range.
- Avoid running the pump against a closed discharge valve for extended periods, as this can lead to overheating.
- Regularly check the pressure gauges (if installed) to ensure the pump is operating within expected parameters.
6.3. Shut-down
- Switch off the power supply to the pump.
- Close isolation valves if the system is to be drained or for maintenance.
7. Údržba
Regular maintenance ensures optimal performance and extends the pump's lifespan. Always disconnect power before performing any maintenance.
7.1. Routine Checks (Weekly/Monthly)
- Inspect for any visible leaks around the pump and piping connections.
- Poslouchejte neobvyklé zvuky nebo vibrace.
- Check the motor temperature; it should not be excessively hot to the touch.
- Ensure the ventilation openings are clear of debris.
7.2. Annual Maintenance
- Inspect the mechanical seal for wear or leaks. Replace if necessary (requires professional service).
- Check the impeller for any signs of corrosion or damage.
- Clean any strainers or filters in the suction line.
- Verify electrical connections are secure and free from corrosion.
7.3. Příprava na zimu (pokud je to relevantní)
If the pump is installed in an area subject to freezing temperatures and will not be used, it must be drained completely to prevent damage from ice expansion. Disconnect power, open drain plugs, and remove any remaining water from the pump casing a potrubí.
8. Řešení problémů
This section provides solutions to common problems. For complex issues, contact a qualified technician.
| Problém | Možná příčina | Řešení |
|---|---|---|
| Čerpadlo se nespustí | Žádné napájení Vypnulo tepelné přetížení Porucha motoru | Zkontrolujte připojení napájení a jistič Allow motor to cool, check for cause of overload Kontaktujte kvalifikovaného technika |
| Čerpadlo běží, ale neteče voda nebo je průtok nízký | Čerpadlo není naplněno Únik vzduchu v sacím potrubí Sací potrubí je ucpané Oběžné kolo poškozené Vypouštěcí ventil uzavřen | Znovu naplňte čerpadlo Zkontrolujte těsnost všech sacích spojů Jasná překážka Inspect/replace impeller (professional service) Open discharge valve |
| Nadměrný hluk nebo vibrace | Cavitation (air in system) Nesouosost Opotřebovaná ložiska Volná montáž | Ensure proper priming, check for air leaks Zkontrolujte vyrovnání čerpadla a motoru Kontaktujte kvalifikovaného technika Utáhněte montážní šrouby |
| Čerpadlo netěsní | Uvolněné spoje Opotřebená mechanická ucpávka Prasklé casing | Utáhněte spoje Replace mechanical seal (professional service) Kontaktujte kvalifikovaného technika |
9. Záruka a podpora
For warranty information, please refer to the documentation provided at the time of purchase or contact your authorized Pedrollo dealer. Keep your proof of purchase for warranty claims.
For technical support, spare parts, or service, please contact your local Pedrollo distributor or the seller from whom you purchased the pump. Provide the model number (CPM150) and serial number (if available) when seeking assistance.
Pedrollo S.p.A. is committed to continuous product improvement. Specifications are subject to change without notice.