1. Konec produktuview
The WAYNE SWS50 1/2 HP Cast Iron Shallow Well Jet Pump is engineered for efficient water transfer from shallow wells. This robust pump is suitable for wells up to 25 feet deep and features a durable cast iron housing. It is designed for reliable performance in various residential and agricultural applications.
Klíčové vlastnosti:
- 1/2 HP motor with a maximum flow rate of 375 gallons per hour (GPH) at 50 PSI.
- Duální voltage capability (120V/240V) with a high-efficiency square flange motor, factory-set for 240V.
- Pre-set pressure switch for automatic operation (30 PSI on, 50 PSI off).
- Durable cast iron volute with a dedicated priming port.
- Thermal protection to prevent motor overheating.
- Sestaveno v USA ze zahraničních i domácích dílů.

Figure 1: WAYNE SWS50 1/2 HP Cast Iron Shallow Well Jet Pump. This image shows the main pump unit with its motor and cast iron housing.
2. Nastavení a instalace
Proper installation is crucial for the optimal performance and longevity of your WAYNE SWS50 pump. Always consult local codes and a qualified professional if you are unsure about any steps.
2.1 Příprava místa
- Ensure the pump is installed on a solid, level surface to minimize vibration.
- Protect the pump from freezing temperatures and direct weather exposure.
- Verify that the well depth does not exceed 25 feet for optimal shallow well pump operation.
2.2 Vodovodní připojení
- The pump features a 1-1/4 inch NPT suction inlet and a 3/4 inch NPT discharge outlet.
- Use appropriate adapters if your existing plumbing differs (e.g., a 7/8 inch NPT to 1 inch NPT adapter for the top output hole if replacing an older pump).
- Install a foot valve or check valve at the end of the suction line in the well to maintain prime.
- Ensure all connections are airtight to prevent air leaks, which can cause priming issues.
2.3 Elektrické připojení
- The pump is dual voltage (120V/240V) and factory-set for 240V. Verify your power supply matches the pump's setting.
- If changing voltage, follow the instructions on the motor label for the quick-change voltage přepínač výběru.
- Connect the pump to a dedicated, properly grounded electrical circuit with appropriate overcurrent protection.
- The pressure switch is pre-set at 30 PSI ON and 50 PSI OFF. Ensure proper wiring to the pressure switch.
2.4 Naplnění čerpadla
The pump self-primes after its housing is filled with water. Follow these steps:
- Remove the priming plug located on the top of the pump housing.
- Fill the pump volute completely with clean water through the dedicated priming port until water overflows.
- Bezpečně nasaďte plnicí zátku.
- Open a faucet or valve on the discharge side of the pump to allow air to escape.
- Turn on the pump. It may take several minutes for the pump to establish prime, especially with long suction lines. Continue to refill the water chamber with cold water every 3-5 minutes if priming takes an extended period.
- Once water flows steadily from the open faucet, close the faucet. The pump should build pressure and shut off automatically at 50 PSI.

Figure 2: Illustrative diagram of a typical shallow well pump installation, showing connections for suction and discharge lines. Note: Actual setup may vary.
3. Návod k obsluze
Once properly installed and primed, the WAYNE SWS50 pump operates automatically based on demand and the pressure switch settings.
- The pump will turn on when the system pressure drops to 30 PSI and turn off when it reaches 50 PSI.
- Ensure there is always water in the well to prevent the pump from running dry, which can cause damage.
- Monitor the pressure gauge (if installed) to confirm proper operation and pressure cycling.
4. Údržba
Regular maintenance helps ensure the long-term reliability and efficiency of your pump.
4.1 Sezónní údržba
- Zima: In areas subject to freezing temperatures, drain the pump completely to prevent damage from ice expansion. Remove the drain plug and priming plug to allow all water to escape. Store the pump in a warm, dry place if possible.
- Spring Startup: Before restarting the pump after winterization, inspect all connections for leaks and ensure the pump is properly primed as described in Section 2.4.
4.2 Obecné kontroly
- Periodically check all plumbing connections for leaks.
- Ensure the pump's mounting is secure and free from excessive vibration.
- Během provozu poslouchejte neobvyklé zvuky, které by mohly naznačovat problém.
5. Řešení problémů
This section provides solutions to common issues you might encounter with your WAYNE SWS50 pump.
| Problém | Možná příčina | Řešení |
|---|---|---|
| Čerpadlo běží, ale není voda nebo je nízký tlak |
|
|
| Pump cycles on and off frequently (short cycling) |
|
|
| Pump motor overheats and shuts off |
|
|
| Čerpadlo se nespustí |
|
|
6. Specifikace
Detailed technical specifications for the WAYNE SWS50 1/2 HP Cast Iron Shallow Well Jet Pump:
- Značka: Wayne
- Číslo modelu: SWS50
- Výkon: 0.5 HP (1/2 HP)
- Materiál: Litina
- Zdroj napájení: Elektrický kabel
- svtage: 120 Volts / 240 Volts (Dual Voltage)
- Maximální průtok: 375 galonů za hodinu (GPH)
- Maximální výška zdvihu: 25 stop
- Nastavení tlakového spínače: 30 PSI ON / 50 PSI OFF
- Suction Connection: 1-1/4 palce NPT
- Vybíjecí přípojka: 3/4 palce NPT
- Rozměry produktu (D x Š x V): 22 cm x 12 cm x 11 cm
- Hmotnost položky: Approximately 1 Pound (Note: This weight seems unusually low for a cast iron pump and may be a data entry error. Refer to product packaging for accurate weight.)
- GTIN/UPC: 040066106117
7. Záruka a podpora
Wayne stands behind the quality of its products.
7.1 Záruka výrobce
The WAYNE SWS50 pump comes with a 3letá omezená záruka od výrobce. Tato záruka se vztahuje na vady materiálu a zpracování při běžném používání a servisu. Uschovejte si prosím doklad o koupi pro případné reklamace.
7.2 Zákaznická podpora
For technical assistance, warranty inquiries, or to purchase replacement parts, please contact Wayne Customer Service. Contact information can typically be found on the product packaging or the official Wayne Pumps webweb (Visit the Wayne Store).