The Walfront STC-100A is a versatile digital temperature controller designed for precise temperature management in various applications, including refrigerating and heating systems. It features a clear digital display, intuitive controls, and robust functionality for maintaining desired temperature ranges.

Klíčové vlastnosti:

  • Refrigerating & Heating Mode: Supports both cooling and heating operations, offering flexibility for different environmental control needs.
  • Uživatelsky přívětivý provoz: Simple and convenient temperature setting with a limited range for ease of use.
  • Pokročilé funkce: Includes temperature correction, sensor failure alarm, and control output delay for enhanced reliability and precision.
  • Přesná regulace teploty: Maintains temperature based on set value and return difference, ensuring stable conditions.
  • Odolná konstrukce: Manufactured from high-quality ABS material for long-term durability and performance.
Walfront STC-100A Digital Temperature Controller front view with red LED display showing '26' degrees Celsius.

Obrázek 1.1: Přední strana view of the Walfront STC-100A Digital Temperature Controller, showing the digital display and control buttons.

2. Důležité bezpečnostní informace

Please read and understand all safety instructions before installing or operating the STC-100A temperature controller. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Elektrické nebezpečí: This device operates on 220VAC. All wiring and installation should be performed by a qualified electrician or knowledgeable individual.
  • Správné zapojení: Carefully distinguish between the relay interface, sensor wiring, and power supply wiring. Incorrect connections can damage the device or connected equipment.
  • Wire Separation: Maintain a proper distance between the sensor wire and the power supply wire to prevent interference and ensure accurate readings.
  • Ověřte svtage: Vždy zkontrolujte, zda napájecí objtage is correct (220VAC) before electrifying the unit.
  • Podmínky prostředí: Do not expose the controller to excessive moisture, dust, or extreme temperatures outside its specified operating range (0℃-60℃, Relative Humidity: No more than 85% non-condensing).
  • Odpojení: Před prováděním jakékoli údržby nebo změn zapojení odpojte napájení.
Zadní view of the Walfront STC-100A Digital Temperature Controller showing the wiring diagram and caution notes.

Obrázek 2.1: Zadní view of the controller with the wiring diagram and important caution notes regarding installation.

3. Obsah balení

Po otevření balení se prosím ujistěte, že jsou všechny součásti přítomny a nepoškozené:

  • 1 x Walfront STC-100A Temperature Controller
  • 1 x Temperature Sensor Cable
  • 1 x Návod k obsluze (tento dokument)

4. Technické specifikace

ParametrHodnota
ModelSTC-100A
MateriálABS
Napájecí zdroj Voltage220VAC ±10%, 50/60Hz
Spotřeba energieMéně než 3W
Rozsah měření teploty-50 ℃ až 99 ℃
Rezoluce1℃
Přesnost±1℃
Output Relay Capacity10A/220VAC
Teplota provozního prostředí0℃ až 60℃
Relativní vlhkostNo more than 85% (non-condensing)
Velikost montážního otvoruApprox. 71 x 29 mm / 2.8 x 1.1 in
Rozměry produktu2.76 x 2.36 x 1.38 palce
Hmotnost položky7 unce (0.2 kilogramů)

5. Instalace a zapojení

The STC-100A is designed for panel mounting. Ensure proper ventilation around the unit.

5.1 Montáž

  • Cut a rectangular opening in your panel with dimensions of approximately 71mm x 29mm (2.8 x 1.1 inches).
  • Vložte ovladač do otvoru zepředu.
  • Secure the controller using the orange mounting clips on the sides. Push them inwards to lock the controller in place.
Strana view of the Walfront STC-100A Digital Temperature Controller showing the orange mounting clips.

Obrázek 5.1: Strana view znázorňující montážní klipy pro instalaci panelu.

5.2 Pokyny pro zapojení

Refer to the wiring diagram on the back of the unit and Figure 5.2 below. Ensure all connections are secure and insulated.

  1. Power Supply (220VAC): Connect your 220VAC power source to terminals 6 and 7. Ensure correct polarity if applicable, though AC typically does not have strict polarity for power input.
  2. Teplotní senzor: Connect the temperature sensor cable to terminals 4 and 5. The sensor is non-polar, so connection order does not matter. Keep this wire separate from power wires.
  3. Output Relay (10A/220VAC):
    • Terminal 1: Common (COM) for the relay output.
    • Terminal 2: Normally Closed (NC) contact.
    • Terminal 3: Normally Open (NO) contact.
    Connect your load (e.g., heater, cooler) to the appropriate relay contacts (COM and NO for heating/cooling, or COM and NC for specific applications) based on your control requirements.
Zadní view of the Walfront STC-100A Digital Temperature Controller showing the terminal block for wiring connections.

Obrázek 5.2: Zadní view showing the terminal block for power, sensor, and relay connections.

6. Návod k obsluze

The STC-100A features a digital display and three buttons: Up (↑), Down (↓), and Set (SET).

Close-up of the Walfront STC-100A Digital Temperature Controller display and buttons.

Figure 6.1: Close-up of the control panel showing the display and buttons.

6.1 Nastavení teploty

  1. Stiskněte tlačítko SOUBOR button once. The display will flash, indicating that you are in temperature setting mode.
  2. Použijte (Nahoru a (Down) buttons to adjust the desired temperature set point.
  3. Stiskněte tlačítko SOUBOR button again to confirm the setting and exit the setting mode. The display will return to showing the current temperature.

6.2 Understanding Control Modes (Refrigerating/Heating)

The STC-100A automatically switches between refrigerating and heating modes based on the set temperature and the current temperature, in conjunction with a configurable "return difference" (hysteresis). This ensures stable temperature control without rapid cycling.

Napřample, if set to 25°C with a 2°C return difference:

  • Režim topení: If the current temperature drops below 23°C (25°C - 2°C), the heating output will activate. It will deactivate when the temperature reaches 25°C.
  • Refrigerating Mode: If the current temperature rises above 27°C (25°C + 2°C), the refrigerating output will activate. It will deactivate when the temperature drops to 25°C.

Note: The specific parameter for setting the return difference (hysteresis) is typically accessed through a hidden menu or a combination of button presses. Refer to the detailed wiring diagram on the unit for advanced parameter settings if available.

6.3 Pokročilé funkce

  • Korekce teploty: Allows for fine-tuning the temperature reading to match a known accurate thermometer. This compensates for any sensor inaccuracies.
  • Alarm selhání senzoru: The unit will display an error code or alarm if the temperature sensor is disconnected or faulty.
  • Control Output Delay: This feature prevents rapid cycling of the compressor or heating element, extending the lifespan of connected equipment. It introduces a delay before the output activates after a temperature change.

Detailed instructions for accessing and adjusting these advanced parameters are usually found in the full technical manual or by consulting the manufacturer's support resources.

7. Údržba

The Walfront STC-100A is designed for minimal maintenance. Follow these guidelines to ensure its longevity and proper operation:

  • Čištění: Pravidelně otírejte displej a casing with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the unit.
  • Větrání: Ensure that the ventilation slots on the sides of the unit are not obstructed to prevent overheating.
  • Kontrola elektroinstalace: Annually inspect all wiring connections for tightness and signs of wear or corrosion.
  • Péče o senzor: Keep the temperature sensor clean and free from debris. Ensure it is properly positioned in the area where temperature needs to be measured.

8. Řešení problémů

This section provides solutions to common issues you might encounter with your STC-100A temperature controller.

ProblémMožná příčinaŘešení
Display is blank / Unit not powering onNo power supply; Incorrect wiring; Blown fuse (external)Check power connections (terminals 6 & 7). Verify supply voltage. Check external fuse or circuit breaker.
"EE" or "HH" error on displayTemperature sensor fault (open circuit, short circuit, or out of range)Check sensor wiring (terminals 4 & 5) for loose connections or damage. Replace sensor if faulty. Ensure temperature is within -50℃ to 99℃.
Odečet teploty je nepřesnýSensor not properly placed; Need for temperature correctionRelocate sensor to a representative area. Use the temperature correction function (refer to advanced settings).
Output (heater/cooler) not activatingIncorrect temperature set point; Hysteresis setting too wide; Output relay wiring issue; Control output delay activeVerify set temperature. Check relay connections (terminals 1, 2, 3). Wait for delay period to expire. Consult advanced settings for hysteresis.
Output cycles too frequentlyHysteresis (return difference) set too narrowIncrease the hysteresis value in the advanced settings to prevent rapid cycling.

If the problem persists after attempting these solutions, please contact Walfront customer support or a qualified technician.

9. Záruka a podpora

For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer. Walfront products are typically covered by a manufacturer's warranty against defects in materials and workmanship.

For technical support, troubleshooting assistance beyond this manual, or inquiries about replacement parts, please visit the official Walfront website or contact their customer service department through the contact information provided with your purchase.

You can also visit the Walfront store on Amazon for more information: Walfront Amazon Store

© 2023 Walfront. All rights reserved.

Tato příručka se může změnit bez předchozího upozornění.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.