Bryant 9450FR
Návod k použití
Bryant 9450FR Průmyslová třída 50 Amp NEMA 14-50 Receptacle
Model: 9450FR | Brand: Bryant
Zavedení
This manual provides essential information for the safe and proper installation, operation, and maintenance of your Bryant 9450FR Industrial Grade 50 Amp NEMA 14-50 Receptacle. Please read all instructions carefully before beginning any work.
Bezpečnostní informace
VAROVÁNÍ: Risk of electric shock or fire. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing this receptacle.
- Ověřte, že je napájení vypnuto pomocí voltage testeru, než se dotknete jakýchkoli vodičů.
- Zajistěte správné uzemnění, abyste zabránili úrazu elektrickým proudem.
- Nepřekračujte stanovený objemtage a amperage ratings of the receptacle.
- Use only appropriate tools and personal protective equipment (PPE).
Obsah balení
Před zahájením instalace ověřte, zda jsou všechny komponenty přítomny a nepoškozené.
- Bryant 9450FR NEMA 14-50 Receptacle
- Montážní šrouby (obvykle součástí balení)
- Pokyny k použití (tato příručka)

Image: The Bryant 9450FR NEMA 14-50 Receptacle shown with the included mounting screws in clear plastic bags.
Nastavení (instalace)
This receptacle is designed for flush mounting. Follow these steps for proper installation:
- Připravte si místo: Ensure you have a suitable electrical box (e.g., 4x4 square box with a 2-gang mud ring or a single-gang box with appropriate adapter) that can accommodate the receptacle and wiring.
- Vypnout napájení: Locate the circuit breaker for the circuit you will be working on and switch it to the OFF position. Verify with a voltage tester that no power is present at the wires.
- Odizolování drátů: Carefully strip approximately 3/4 inch (19mm) of insulation from the ends of the supply wires. For 14-50R, you will typically have two hot wires (black/red), one neutral wire (white), and one ground wire (green/bare copper).
- Připojit dráty: The Bryant 9450FR features clearly marked terminals.
- Připojte ZELENÝ or bare copper ground wire to the terminal marked "GREEN" (grounding screw).
- Připojte BÍLÝ neutral wire to the terminal marked "WHITE" (neutral screw).
- Spojte oba HORKÝ wires (black and red) to the remaining two terminals marked "XXX" (line screws).

Obrázek: Zadní view of the receptacle showing the screw terminals labeled for proper wire connection (White, Green, and two Hot).
- Zabezpečená připojení: Tighten all terminal screws firmly to ensure good electrical contact. Tug gently on each wire to confirm it is securely fastened.
- Montážní zásuvka: Carefully fold the wires into the electrical box. Align the receptacle with the mounting holes in the electrical box and secure it using the provided mounting screws. Do not overtighten.
- Install Faceplate (Not Included): Once the receptacle is securely mounted, install a compatible NEMA 14-50 faceplate (sold separately) over the receptacle.
- Obnovit napájení: Go back to the circuit breaker or fuse box and switch the power back ON.

Obrázek: Přední strana view of the Bryant 9450FR NEMA 14-50 Receptacle, ready for faceplate installation.
Návod k obsluze
The Bryant 9450FR NEMA 14-50 Receptacle is designed for use with NEMA 14-50 compatible plugs. To operate:
- Ensure the appliance or device you intend to connect is rated for 125/250V and does not exceed 50 Amps.
- Align the prongs of the NEMA 14-50 plug with the corresponding slots on the receptacle.
- Firmly insert the plug into the receptacle until it is fully seated.
- To disconnect, firmly grasp the plug and pull it straight out from the receptacle. Do not pull by the cord.
Údržba
The Bryant 9450FR receptacle requires minimal maintenance. Regular inspection is recommended:
- Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections.
- Ensure the faceplate is securely attached.
- Keep the receptacle clean and free of dust or debris. Use a dry cloth for cleaning. Do not use liquid cleaners.
- If any damage is observed, disconnect power to the circuit and have the receptacle inspected and replaced by a qualified electrician.
Odstraňování problémů
If you experience issues with your receptacle, consider the following common troubleshooting steps:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Žádné napájení ze zásuvky. | Vypadl jistič nebo spálená pojistka. | Check and reset the circuit breaker or replace the fuse. If it trips repeatedly, consult an electrician. |
| Plug does not fit. | Incorrect plug type or foreign object in receptacle. | Ensure you are using a NEMA 14-50 compatible plug. Inspect slots for obstructions (with power off). |
| Nádoba je teplá na dotek. | Přetížení nebo uvolněné spojení. | Disconnect the load. If it persists, turn off power and have an electrician inspect wiring and connections. |
For issues not covered here, or if problems persist, contact a qualified electrician.
Specifikace
| Číslo modelu: | 9450FR |
| Typ: | Industrial Grade 50 Amp NEMA 14-50 Receptacle |
| svtage Hodnocení: | 125/250V |
| Amperage hodnocení: | 50 Amp |
| Poles/Wires: | 3 Pole, 4 Wire Grounding |
| Typ montáže: | Single Flush |
| Materiál: | Nylon (housing) |
| Barva: | Černý |
| Výrobce: | Bryant |
Záruka
This Bryant product is manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the manufacturer's official webUschovejte si doklad o koupi pro případ reklamace.
Podpora
For technical assistance or further inquiries, please contact the manufacturer or your authorized distributor. Always provide the model number (9450FR) when seeking support.
Výrobce: Bryant (a Hubbell brand)
Webmísto: www.hubbell.com/bryant/en