The SMARTGEN HGM1790N genset controller is designed for single unit automation and monitoring control, suitable for both generator and pumping unit applications. It supports manual and remote start/stop operations. This controller monitors and protects genset operation by collecting and analyzing data such as generator voltage, current, water temperature, and oil pressure. Fault conditions are displayed on the graphical LCD, providing effective alarm signals for timely maintenance.
Klíčové vlastnosti:
- Low cost controller designed to start/stop a generator manually and remotely.
- Suitable for 1-3 phase gasoline and diesel gensets.
- Designed for front panel mounting.
- Survives cranking dropouts.
- Generator protection, built-in alarms and warnings.
- Graphical LCD display with backlight and LED indicators for clear status monitoring.
- Silicone panel and buttons for enhanced high and low temperature adaptation.
- Wide power supply range DC (8~35)V, compatible with 12V or 24V starter batteries.
2. Nastavení a instalace
Proper installation is crucial for the reliable operation of the HGM1790N controller. This section outlines the physical mounting and electrical connections.
2.1 Fyzická instalace
The HGM1790N controller is designed for front panel mounting. Ensure the panel cutout dimensions are accurate for a secure fit. The case dimensions are 95mm x 86mm x 46.5mm, and the panel cutout is 78mm x 66mm. When installing, ensure the waterproof rubber gasket is used between the controller and the panel fascia to achieve IP55 protection level.

Obrázek 2.1: Přední strana view of the HGM1790N controller, showing the LCD display, LED indicators, and control buttons (Stop, Auto, Start).
2.2 Elektrické připojení
All electrical connections should be made with the power supply disconnected. Refer to the wiring diagram for detailed connections. The controller operates on a DC (8~35)V power supply, compatible with 12V or 24V starter batteries. Ensure correct polarity when connecting the battery (B+ and B- terminals).

Obrázek 2.2: Zadní view of the HGM1790N controller, displaying the labeled terminal blocks for various inputs and outputs, including Magnetic Pickup, Engine Temp Input, Oil Pressure Input, Aux. Input, Remote Start Input, Crank Output, Fuel Output, Em. Stop Input, B+, B-, GENS (L, N), Load (I*, I), Idle Output, Stop Output, and Aux. Output.

Figure 2.3: Detailed wiring schematic for the HGM1790N controller, illustrating connections for power, load, remote start, auxiliary inputs, engine sensors (oil pressure, temperature), and magnetic pickup. Note: Start and fuel output ports should use large capacity relays. When sensor port configured as "high digital input is active", hanging in air means high electrical level is selected; cannot be connected to power supply positive.
Důležité poznámky k zapojení:
- Start and Fuel Output: These ports require large capacity relays for proper operation.
- Konfigurace senzoru: If a sensor port is configured for "high digital input is active", leaving it unconnected (hanging in air) will result in a high electrical level. Do not connect such a port directly to the positive power supply.
- Kompatibilita snímačů: The controller is compatible with multiple temperature, pressure, and fuel level sensors. These can be user-defined and used directly. Temperature and pressure sensors can be used in parallel with an annunciator, providing analog quantity and increasing protection level.
3. Návod k obsluze
The HGM1790N controller offers three primary operating modes: Manual, Auto, and Stop. Operation is managed via the touch-buttons on the front panel.
3.1 Ovládací tlačítka
- Tlačítko Stop (červené): Used to stop the genset and enter Stop mode.
- Auto Button (White/Grey with swirl icon): Used to select Auto mode, enabling remote start/stop functionality.
- Tlačítko Start (zelené): Used to manually start the genset.
3.2 Provozní režimy
Režim zastavení: In this mode, the genset is stopped. Press the Stop button to enter this mode. The controller will cease all operations and clear any active alarms.
Manuální režim: To manually start the genset, press the Start button. The controller will initiate the starting sequence. To stop, press the Stop button.
Automatický režim: Press the Auto button to enable automatic operation. In Auto mode, the controller will respond to remote start/stop signals. The genset will start automatically upon receiving a valid remote start signal and stop when the signal is removed or a fault occurs.
3.3 Parameter Monitoring and Display
The graphical LCD displays various genset parameters and fault conditions. Parameters measured and displayed include:
- Generator Voltage (V)
- Generator Frequency (Hz)
- Generator Power (kW)
- Generator Current (A)
- Načíst procentotage (%)
- Tlak oleje (kPa)
- Teplota (° C / ° F)
- Hladina paliva (%)
- Total Running Time (H, max. 199999 hours)
- Baterie Voltage (V)
- Otáčky motoru (RPM)
- Akumulované počáteční časy (max. 199999krát, zobrazeno na PC)
Parameter thresholds and delay values can be adjusted via the front panel or through a USB port connected to PC software.
4. Údržba
Regular maintenance ensures the longevity and optimal performance of your HGM1790N controller. While the unit is designed for durability, periodic checks are recommended.
- Čištění: Keep the front panel clean and free of dust and debris. Use a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Spojení: Periodically check all wiring connections for tightness and signs of corrosion. Loose connections can lead to intermittent operation or faults.
- Podmínky prostředí: Zajistěte, aby provozní prostředí zůstalo v rámci specifikovaného rozsahu teploty a vlhkosti, aby nedošlo k poškození vnitřních součástí.
- Aktualizace firmwaru: Zkontrolujte výrobce website for any available firmware updates that may improve performance or add features. Updates are typically performed via the USB port with PC software.
5. Řešení problémů
The HGM1790N controller provides fault protection and display functions. When a fault occurs, the graphical LCD will display the condition, and effective alarm signals will be provided.
5.1 Běžné problémy a řešení
| Problém | Možná příčina | Řešení |
|---|---|---|
| Ovladač se nezapne. | Žádné napájení nebo nesprávná hlasitosttage. | Check battery connections (B+, B-). Ensure power supply is within DC (8~35)V range. |
| Genset fails to start in Manual mode. | Incorrect wiring for crank/fuel output, or engine issue. | Verify crank and fuel output wiring, ensure large capacity relays are used. Check engine's starting system. |
| Genset fails to start in Auto mode. | No remote start signal, or incorrect remote start input wiring. | Check remote start signal source and wiring to the controller's remote start input. |
| Inaccurate sensor readings (Oil Pressure, Temp, Fuel Level). | Sensor malfunction, incorrect sensor type selected, or wiring issue. | Verify sensor wiring. Check controller settings to ensure the correct sensor type is configured. Replace faulty sensor if necessary. |
| Alarm displayed on LCD. | Indicates a fault condition (e.g., low oil pressure, high temperature, over-voltagE). | Identify the specific alarm message on the LCD. Address the underlying issue (e.g., check oil level, coolant level, generator output). |
For persistent issues, refer to the detailed fault codes and diagnostic procedures in the comprehensive technical manual (if available from the manufacturer) or contact customer support.
6. Technické specifikace
This section provides detailed technical specifications for the HGM1790N controller.

Figure 6.1: Official specification table for the HGM1790N genset controller, detailing items such as Working Voltage, Power Consumption, Alternator Voltage/Frequency, Sensor Speed Voltage/Frequency, Relay Outputs, Case Dimensions, Panel Cutout, CT Secondary Current, Working/Storage Conditions, Protection Level, Insulation Intensity, and Weight.
| Položka | Obsah |
|---|---|
| Pracovní svtage | DC (8~35)V, Continuous Power Supply |
| Spotřeba energie | <1.2W (pohotovostní režim: <0.5W) |
| Alternátor svtage Vstup | AC 15V ~ AC 360V (ph-N) |
| Frekvence alternátoru | 50/60 Hz |
| Snímač rychlosti Voltage | 1.0 V až 24 V (RMS) |
| Frekvence snímače rychlosti | Max. 10KHz |
| Spusťte reléový výstup | 1Amp DC28V DC B+ power supply |
| Výstup palivového relé | 1Amp DC28V DC B+ power supply |
| Aux. Výstup1 | 1Amp DC28V DC B+ power supply |
| Aux. Výstup2 | 1Amp DC28V DC B+ power supply |
| Aux. Výstup3 | 1Amp DC28V DC B+ power supply |
| Programovatelný digitální vstup | Aktivní při připojení k B- |
| Rozměry pouzdra | 95 mm x 86 mm x 46.5 mm |
| Výřez panelu | Rozměr 78 mm x 66 mm |
| Sekundární proud CT | Jmenovitý proud: 5A |
| Pracovní podmínky | Temperature: (-25~+70)°C, Humidity: (20~93)%RH |
| Skladovací stav | Teplota: (-25~+70)°C |
| Úroveň ochrany | IP55 (When waterproof rubber gasket installed between the controller and panel fascia) |
| Intenzita izolace | Připojte AC2.2kV objtage mezi AC vysoktage koncový a nízký objtage svorka (unikající proud pod 3 mA za 1 minutu). |
| Hmotnost | 0.18kg (approx. 8.1 ounces) |
7. Informace o záruce
Specific warranty details for the SMARTGEN HGM1790N controller are typically provided at the point of purchase or on the manufacturer's official website. Please retain your proof of purchase for warranty claims. Standard warranties usually cover defects in materials and workmanship under normal use. Damage resulting from improper installation, misuse, or unauthorized modifications is generally not covered.
For detailed warranty terms and conditions, please refer to the documentation included with your product or visit the official SMARTGEN webmísto.
8. Zákaznická podpora
If you encounter issues not covered in the troubleshooting section or require further assistance, please contact SMARTGEN customer support or your authorized dealer.