Walfront Walfrontafg3g8tdsy-03

Walfront DC 5V 12V 24V Adjustable Cycle Trigger Delay Timing Timer Relay On/Off Switch User Manual

Model: Walfrontafg3g8tdsy-03

Konec produktuview

The Walfront DC 5V 12V 24V Adjustable Cycle Trigger Delay Timing Timer Relay On/Off Switch is a versatile module designed for precise timing control in various applications. It features adjustable "on" and "off" times and supports both mon (single) and cycle modes. This module is ideal for timer-operated equipment, repetitive test circuits, and intermittent pump control in systems like fish tanks.

Walfront Timer Relay Module

Figure 1: Walfront DC Timer Relay Module. This image shows the top view of the green circuit board with a blue relay, two potentiometers for time adjustment, and terminal blocks for connections.

Specifikace

SpecifikaceHodnota
Vstupní objemtage MožnostiDC 5V, DC 12V, DC 24V (model dependent)
Klidový proud<10 mA
Dynamický proud45mA@12V; 90mA@5V; 30mA@24V
Typ kontaktu1 group NO+NC (Normally Open + Normally Closed)
Kapacita zatížení10A (AC0-250V, DC0-30V)
Rozměry modulu70 mm x 20 mm x 18 mm (2.75" x 0.78" x 0.7")
Přesnost časuMax value * 0.001
Adjustable Time Ranges
  • DC5V: 0-30min / 0-24hr
  • DC12V: 0-120min / 0-24hr
  • DC24V: 0-15min / 0-30min
Typ konektoruKabelové
Kontaktní materiálStříbrná slitina
Typ montážePovrchová montáž
Walfront Timer Relay Module Dimensions

Figure 2: Dimensions of the Walfront Timer Relay Module. The image shows the module with measurements indicating a length of 70mm and a width of 20mm.

Nastavení a zapojení

Proper wiring is crucial for the safe and correct operation of the timer relay module. Always ensure the power supply matches the module's voltage rating (5V, 12V, or 24V DC) and observe polarity.

Schéma zapojení přesview

The module supports different wiring configurations depending on whether the load shares the same power supply as the module or uses a separate power supply.

Walfront Timer Relay Module Wiring Diagram

Figure 3: Detailed Wiring Diagram for the Walfront Timer Relay Module. This diagram illustrates connections for the module's power supply, a start-up button, and a load, emphasizing not to reverse power supply polarity.

Spojovací body

  • Příkon: Connect your DC power supply to the '+' and '-' terminals. Ensure correct polarity.
  • Key Input: The 'Key' terminals are for an external trigger switch (e.g., a push button). Shorting these two wires will trigger the module. If you need the module to work recurrently after power on, connect these two wires directly.
  • Reléový výstup: The relay has three terminals:
    • NC (normálně zavřeno): Connected to COM when the relay is off.
    • COM (běžné): Společný terminál pro reléový spínač.
    • NE (normálně otevřeno): Connected to COM when the relay is on.
    Connect your load (e.g., motor, light) to COM and either NO or NC depending on your desired operation (normally off or normally on).

Wiring Reference 1: Shared Power Supply

In this configuration, the module and the load share the same power source. This is suitable for DC loads that operate at the module's input voltage.

Wiring Diagram 1: Shared Power Supply

Figure 4: Wiring Reference 1. This diagram shows the module and load connected to a single power supply (BT1), with the load connected between the COM and NO terminals of the relay, and a trigger switch (S1 Key) connected to the module's key input.

Wiring Reference 2: Separate Power Supply for Load

This configuration allows the module to control a load that uses a different voltage (AC or DC) than the module's power supply. The relay acts as a switch for the load's independent circuit.

Wiring Diagram 2: Separate Power Supply for Load

Figure 5: Wiring Reference 2. This diagram illustrates the module powered by one supply, while the load is powered by a separate supply (DC or AC) through the relay's COM and NO terminals. A trigger switch (S1 Key) is also shown.

Návod k obsluze

The module supports two main operating modes: Mon (single trigger) and Cycle. The timing for "on" and "off" states is adjustable using the onboard potentiometers.

Výběr režimu

The operating mode is selected using a jumper on the module. Locate the jumper labeled "Mon" and "Cyc".

  • Mon Mode (Single Trigger): When the jumper is on "Mon", the module operates in single trigger mode. Upon receiving a trigger, the relay will switch on, and after the set delay time, it will switch off. If triggered again during the delay process, the current delay will be interrupted and reset.
  • Režim cyklu: When the jumper is on "Cyc", the module operates in cycle mode. Upon receiving a trigger, the relay will switch on for a set "on" time (T1), then switch off for a set "off" time (T2), and this cycle will repeat indefinitely until interrupted. If triggered again during the delay process, the current delay will be interrupted and reset.
Walfront Timer Relay Module Mode and Time Range Selection

Figure 6: Jumper settings for selecting working mode (Mon/Cycle) and time range (T/T10). The image highlights the two jumpers on the circuit board.

Úprava času

The module features two adjustable potentiometers for setting the timing intervals. These are typically labeled for "on" time and "off" time, or T1 and T2 in cycle mode.

  • Adjust "On" Time (T1): Use the potentiometer labeled "+OnT" or similar to set the duration the relay remains active.
  • Adjust "Off" Time (T2): Use the potentiometer labeled "+OffT" or similar to set the duration the relay remains inactive (in cycle mode).

The time range can also be adjusted using a separate jumper, typically labeled "T" and "T/10".

  • "T" Position: Normal time range.
  • "T/10" Position: Time is divided by 10, allowing for finer adjustment within a smaller range.
Walfront Timer Relay Module Potentiometer Adjustment

Figure 7: Potentiometers for adjusting "on" and "off" times. The image points out the two blue potentiometers and the power and switch indicator LEDs.

Kontrolky

  • Indikátor napájení: Illuminates when the module is powered on.
  • Indikátor přepínače: Illuminates when the relay is active (switched on).

Aplikace

This versatile timer relay module can be used in a variety of applications requiring precise timing and control:

  • Timer operating equipment
  • Machine repetitive test circuits
  • Fish tank intermittent pump control
  • Automated lighting systems
  • DIY automation projects
  • Průmyslové řídicí systémy
Walfront Timer Relay Module Application Example

Obrázek 8: Přample application of the Walfront Timer Relay Module. The image shows the module alongside a conveyor belt sealing machine, illustrating its use in automated processes.

Odstraňování problémů

If you encounter issues with your Walfront Timer Relay Module, consider the following troubleshooting steps:

  • Modul se nezapíná:
    • Ověřte vstupní objemtage matches the module's rating (5V, 12V, or 24V DC).
    • Check power supply connections for correct polarity (+ to +, - to -). Reverse polarity can damage the module.
    • Ensure the power supply is providing sufficient current.
  • Relay Not Triggering/Switching:
    • Confirm the 'Key' input is correctly wired and the trigger signal is being applied (e.g., button press, short circuit).
    • In Mon mode, ensure the trigger is a momentary signal if continuous triggering is not desired.
    • Check the potentiometer settings; they might be set to a very short or very long duration.
    • Verify the mode jumper (Mon/Cyc) is correctly positioned for your desired operation.
  • Inconsistent Timing:
    • Ensure the power supply is stable and free from significant voltage výkyvy.
    • Check the "T" / "T/10" jumper setting to ensure the correct time scaling is selected.
    • Adjust potentiometers slowly and test to find the desired timing.
  • Load Not Operating:
    • Verify the load's power supply is connected and functional.
    • Check the relay output connections (COM, NO, NC) to ensure the load is wired to the correct terminals for your desired operation.
    • Ensure the load's current and voltage requirements do not exceed the relay's load capacity (10A, AC0-250V, DC0-30V).

Údržba

The Walfront Timer Relay Module is designed for low maintenance. Follow these guidelines to ensure its longevity:

  • Udržujte v čistotě: Periodically clean the module with a soft, dry cloth to remove dust and debris. Avoid using liquids or harsh chemicals.
  • Podmínky prostředí: Operate the module within its specified temperature and humidity ranges. Avoid extreme temperatures, direct sunlight, and high moisture environments.
  • Zabezpečená připojení: Regularly check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or damage.
  • Vyvarujte se přetížení: Do not exceed the specified load capacity of the relay (10A, AC0-250V, DC0-30V). Overloading can damage the relay and the module.

Záruka a podpora

For warranty information and technical support, please refer to the Walfront official webnebo se obraťte na prodejce. Uschovejte si účtenku jako doklad o koupi.

For further assistance, you may visit the Walfront Store on Amazon: Walfront Store.

© 2024 Walfront. All rights reserved.

This manual is for informational purposes only. Walfront is not responsible for any damages or injuries resulting from improper use or installation of this product.