Lightkiwi H5576
Uživatelská příručka digitálního časovače Lightkiwi H5576
Model: H5576
1. Úvod
The Lightkiwi H5576 Digital Timer is designed to provide automated control for your low voltage landscape lighting system. This timer offers convenience and energy efficiency by allowing you to program specific on/off times for your lights. Its robust features and easy-to-read display make it an ideal solution for managing your outdoor illumination.
Klíčové vlastnosti:
- Automatically Turns Your Low Voltage Lighting System On/Off
- Easy Set Up Operation
- Large, Easy to Read Digital LCD Display
- Automatic or Manual Operation
- Program Up To 18 On/Off Settings Per Week

2. Bezpečnostní informace
Please read all instructions carefully before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.
- Neponořujte časovač do vody ani jej nevystavujte nadměrné vlhkosti.
- Ensure the timer is properly plugged into a compatible outlet.
- Nepřekračujte maximální elektrické jmenovité hodnoty: 15 Amps, 1875 Watts Resistive or General Purpose; 8 Amps, 1000 Watts Tungsten.
- This timer is designed for 125 Volts AC, 60 Hz applications.
- Uchovávejte mimo dosah dětí.
- Před čištěním nebo prováděním jakékoli údržby odpojte napájení.
3. Pokyny k nastavení
The Lightkiwi H5576 Digital Timer is designed for easy integration with your low voltage landscape lighting system. It is specifically compatible with the Lightkiwi 300 Watt Transformer (Model# W9715). Please note that this timer does not fit into 75 watt transformers due to their built-in mechanical timers.
Počáteční nastavení:
- Vybalte časovač: Opatrně vyjměte časovač z obalu.
- Inspect the Timer: Zkontrolujte, zda nejsou viditelná poškození.
- Připojit: Insert the timer directly into a standard 125V AC, 60Hz wall outlet or the designated timer receptacle on your compatible Lightkiwi transformer. The timer features a battery backup to retain settings during power outages.
- Připojit zařízení: Plug the device you wish to control (e.g., your landscape lighting transformer) into the outlet on the side of the digital timer.


Video nastavení:
Watch this official Lightkiwi video for a visual guide on setting up your timer with a Lightkiwi transformer:
Video: Timers for Lightkiwi Transformer. This video demonstrates the compatibility and connection of Lightkiwi timers with Lightkiwi transformers.
4. Návod k obsluze
The H5576 Digital Timer allows for both automatic and manual operation, with the ability to program up to 18 on/off settings per week. The large LCD display ensures easy readability.
Nastavení aktuálního času:
- Stiskněte tlačítko ČAS tlačítko. Zobrazení hodin bude blikat.
- Použijte UP a DOLŮ tlačítka pro nastavení hodiny.
- Stiskněte ČAS again. The minute display will flash.
- Použijte UP a DOLŮ tlačítka pro nastavení minut.
- Stiskněte ČAS again. The day of the week will flash.
- Použijte UP a DOLŮ tlačítka pro výběr aktuálního dne.
- Stiskněte ČAS pro potvrzení a ukončení režimu nastavení času.
Programming On/Off Cycles:
You can set up to 18 distinct ON/OFF programs. Each program consists of an ON time and an OFF time.
- Stiskněte tlačítko SOUBOR button. The display will show "1 ON" and the hour will flash.
- Použití UP a DOLŮ to set the desired ON hour for program 1.
- Stiskněte SOUBOR. Set the ON minutes using UP a DOLŮ.
- Stiskněte SOUBOR. Set the day(s) of the week for this ON program using UP a DOLŮ. You can choose individual days, weekdays, weekends, or all days.
- Stiskněte SOUBOR. The display will show "1 OFF" and the hour will flash.
- Repeat steps 2-4 to set the desired OFF time and day(s) for program 1.
- Pokračujte v stisknutí SOUBOR to cycle through programs 2-18 and set them as needed. If you do not need all 18 programs, simply press CTD pro ukončení programovacího režimu.
Ruční ovládání:
To manually turn the connected device ON or OFF, press the MANUÁL button. Each press will cycle through ON, OFF, and AUTO modes. In AUTO mode, the timer will follow your programmed settings.
Náhodná funkce:
The RND (Random) button can be used to activate a random on/off pattern, which can be useful for security purposes when you are away. Consult the full user guide (link in product documents) for detailed instructions on using the random function.
5. Údržba
The Lightkiwi H5576 Digital Timer requires minimal maintenance to ensure long-lasting performance.
- Čištění: Wipe the timer with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the timer is unplugged before cleaning.
- Skladování: Pokud časovač skladujete delší dobu, ujistěte se, že je čistý a suchý. Skladujte na chladném a suchém místě mimo dosah přímého slunečního záření.
- Bateriová záloha: The internal battery maintains settings during power outages. If the display is blank or settings are lost frequently, the battery may need to be recharged by keeping the unit plugged in for several hours.
6. Řešení problémů
If you encounter issues with your Lightkiwi H5576 Digital Timer, please refer to the following common problems and solutions:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Displej časovače je prázdný. | No power; internal battery drained. | Ensure the timer is securely plugged into a live outlet. Leave it plugged in for several hours to recharge the internal battery. |
| Connected device does not turn on/off at programmed times. | Incorrect programming; timer in manual mode; power outage. | Verify your ON/OFF programs are set correctly. Press the MANUÁL button until the timer is in AUTO mode. Check for power outages. |
| Problém s programováním časovače. | Neznalost posloupnosti tlačítek. | Refer to the "Operating Instructions" section (Section 4) and follow the steps carefully. It may be helpful to unplug the timer and program it in a comfortable setting before re-installing. |
| Timer trips circuit breaker. | Overload; incompatible transformer. | Ensure the connected load does not exceed the timer's maximum wattage (1875W). Verify compatibility with your transformer (e.g., Lightkiwi 300W Transformer Model# W9715). Do not use with 75W transformers. |
7. Specifikace
| Specifikace | Detail |
|---|---|
| Číslo modelu | H5576 |
| Značka | Lightkiwi |
| Barva | Bílý |
| Materiál | Plast |
| Vstupní objemtage | 125 V AC, 60 Hz |
| Max. Input Current/Watt | 15 Amps, 1875 Watts Resistive or General Purpose |
| Tungsten Rating | 8 Amps, 1000 Wattů wolfram |
| Počet nastavení | Up to 18 On/Off settings per week |
| Rozměry produktu | 3.5 x 3 x 2.5 palce |
| Hmotnost položky | 3.84 unce |
| Certifikace | Seznam ETL |
| UPC | 615953178111 |
8. Záruka a podpora
Lightkiwi is committed to providing high-quality products. For specific warranty information regarding your H5576 Digital Timer, please refer to the documentation included with your purchase or visit the official Lightkiwi webmísto.
Zákaznická podpora:
If you have any questions, require technical assistance, or need to report an issue, please contact Lightkiwi customer support. You can find contact information and additional resources by visiting the Lightkiwi Brand Store on Amazon nebo jejich úředník webmísto.
Ask a question about this manual