1. Úvod a konecview
The Singer Atlantic Personal 20L Room Cooler is designed to provide efficient cooling for personal spaces. This compact unit features a 20-liter water tank, three-sided honeycomb cooling pads, and castor wheels for easy mobility. It includes motorized vertical louvers for enhanced air distribution and a convenient drain plug for simplified cleaning.

Obrázek 1: Přední strana view of the Singer Atlantic Personal 20L Room Cooler, showing the control panel and air outlet.
2. Bezpečnostní pokyny
Před použitím tohoto spotřebiče si prosím přečtěte a pochopte všechny bezpečnostní pokyny, abyste předešli zranění nebo poškození.
- Always ensure the cooler is placed on a stable, level surface to prevent tipping and water spillage.
- Do not immerse the cooler, power cord, or plug in water or other liquids.
- Zajistěte napájení objtage odpovídá jmenovité hodnotě uvedené na spotřebiči.
- Unplug the cooler from the power outlet before filling or draining water, cleaning, or performing any maintenance.
- Udržujte spotřebič mimo dosah dětí a domácích zvířat.
- Do not operate the cooler with a damaged power cord or plug. Contact customer support for repairs.
- Avoid placing objects into the air inlet or outlet grilles.
- Do not use the cooler in areas with high humidity or near flammable materials.
3. Komponenty produktu
Familiarize yourself with the main parts of your Singer Atlantic Personal Room Cooler:
- Hlavní jednotka: The primary housing of the cooler.
- Nádrž na vodu: Located at the bottom, holds up to 20 liters of water.
- Chladicí podložky s voštinovým vzorem: Three-sided pads for enhanced cooling efficiency.
- Ovládací panel: Knobs for fan speed and cooling/swing functions.
- Mřížka výstupu vzduchu: Front grille with motorized vertical louvers.
- Indikátor hladiny vody: Průhledné okénko na přední straně pro sledování hladiny vody.
- Pojezdová kola: Four wheels for easy movement.
- Přívod vody: Located at the rear for filling water.
- Vypouštěcí zátka: Located at the bottom rear for draining water.

Figure 2: Close-up of the control panel with 'Swing/Cool' and 'Air Flow' knobs.

Obrázek 3: Zadní view of the cooler, showing the water inlet at the top and the drain plug at the bottom.

Obrázek 4: Strana view of the cooler, highlighting the honeycomb cooling pads.

Figure 5: Lower front view showing the water level indicator and castor wheels for portability.
4. Nastavení
- Rozbalení: Carefully remove the cooler from its packaging. Retain all packaging materials for future storage or transport.
- Umístění: Place the cooler on a firm, level surface. For optimal cooling, position the cooler near an open window or door to allow fresh air intake. Ensure there is adequate space around the unit for proper airflow.
- Naplňte nádrž na vodu: Open the water inlet at the rear of the cooler. Fill the water tank with clean, cool water. Monitor the water level indicator on the front to ensure you do not exceed the 'MAX' mark. For enhanced cooling, you may add ice cubes to the water tank.
- Připojte napájení: Plug the power cord into a suitable 230V AC electrical outlet. Ensure the outlet is properly grounded.
5. Návod k obsluze
The control panel features two rotary knobs:
- Air Flow (Fan Speed) Knob: Controls the fan speed. Turn the knob to select from 'LO' (Low), 'MED' (Medium), or 'HI' (High) settings. Turn to 'OFF' to switch off the fan.
- Swing/Cool Knob: Controls the cooling and swing functions.
- Turn to 'SWING' to activate the motorized vertical louvers, which oscillate to distribute air across a wider area.
- Turn to 'COOL' to activate the water pump and cooling function. Water will be circulated over the honeycomb pads, providing evaporative cooling.
- Turn to 'OFF' to deactivate both cooling and swing functions.
Provozovat:
- Ensure the water tank is filled to an appropriate level.
- Plug in the cooler.
- Turn the 'Air Flow' knob to your desired fan speed (LO, MED, or HI).
- To activate cooling, turn the 'Swing/Cool' knob to 'COOL'. For oscillating airflow, turn it to 'SWING'. You can use both functions simultaneously by setting the knob to 'COOL' and then adjusting the 'Air Flow' knob.
- To turn off the cooler, set both knobs to 'OFF'.
6. Údržba
Regular maintenance ensures optimal performance and longevity of your cooler.
6.1. Daily/Weekly Maintenance
- Nádrž na vodu: Regularly check the water level and refill as needed. If the cooler is not used for an extended period, drain the water completely to prevent stagnation and odor.
- Čištění exteriéru: Vnější povrchy otřete měkkým, damp tkanina. Nepoužívejte abrazivní čisticí prostředky nebo rozpouštědla.
6.2. Měsíční údržba
- Vypustit vodu: Unplug the cooler. Locate the drain plug at the bottom rear of the unit. Remove the plug to completely drain the water tank.
- Nádrž na čistou vodu: After draining, clean the inside of the water tank with a mild detergent and water. Rinse thoroughly to remove any residue.
- Clean Honeycomb Pads: The honeycomb pads can be removed for cleaning. Gently rinse them under running water to remove dust and mineral deposits. Allow them to dry completely before reinserting.
6.3. Skladování
Při delším skladování chladiče:
- Vypusťte veškerou vodu z nádrže a důkladně ji vyčistěte.
- Clean the honeycomb pads and allow them to dry completely.
- Vyčistěte vnější část jednotky.
- Store the cooler in a dry, dust-free place, preferably in its original packaging.
7. Řešení problémů
If you encounter issues with your cooler, refer to the following table for common problems and solutions:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Cooler does not turn on | Žádné napájení Napájecí kabel není správně zapojen Porucha elektrické zásuvky | Zkontrolujte, zda je napájecí kabel bezpečně zapojený do funkční zásuvky. Otestujte zásuvku pomocí jiného spotřebiče. Zkontrolujte jistič v domácnosti. |
| Žádný chladivý účinek | Prázdná nádrž na vodu Funkce chlazení není aktivována Honeycomb pads are dry | Naplňte nádržku na vodu po úroveň „MAX“. Ensure the 'Swing/Cool' knob is set to 'COOL'. Allow a few minutes for water to saturate the pads after activating cooling. |
| Únik vody | Přeplněná nádrž na vodu Drain plug not securely closed Cooler not on a level surface | Do not fill water above the 'MAX' indicator. Ensure the drain plug is firmly inserted. Umístěte chladič na rovný a stabilní povrch. |
| Slabé proudění vzduchu | Otáčky ventilátoru jsou nastaveny příliš nízko Zablokován vstup/výstup vzduchu Dust accumulation on pads/fan | Increase the fan speed using the 'Air Flow' knob. Ensure no obstructions are blocking the grilles. Clean the honeycomb pads and fan blades as per maintenance instructions. |
Pokud problém přetrvává i po vyzkoušení těchto řešení, kontaktujte zákaznickou podporu.
8. Specifikace
Detailed technical specifications for the Singer Atlantic Personal 20L Room Cooler:
- Název modelu: Atlantic Personal
- Typ: Personal Room Cooler
- Kapacita: 20 litru
- Air Throw: 20 stop
- Spotřeba energie: 130 wattů
- Dodávka vzduchu: Up to 1250 Cubic m/hr
- Rychlost motoru: 1350 ot./min
- Počet otáček ventilátoru: 3 (nízká, střední, vysoká)
- svtage: 230 voltů (AC)
- Cooling Medium: Honey Comb Cooling Pads (3-sided)
- Materiál: Plast
- Typ montáže: Volné stání
- Typ ovládání: Knoflík
- Speciální vlastnosti: 4 Castor Wheels for portability, Motorized Vertical Louvers, Drain Plug for easy cleaning, Inverter Compatible.

Figure 6: Approximate dimensions of the cooler: 41.5 cm (width) x 66.5 cm (height).
9. Informace o záruce
This Singer Atlantic Personal 20L Room Cooler comes with a 1-letá záruka on the product from the date of purchase. Please retain your purchase receipt for warranty claims. The warranty covers manufacturing defects under normal use conditions. It does not cover damage resulting from misuse, accident, unauthorized repair, or normal wear and tear.
10. Zákaznická podpora
For any queries, service requests, or technical assistance, please contact Singer India Limited customer support:
- Telefon: 18001033474 8860118855 XNUMX | XNUMX XNUMX XNUMX
- E-mail: zákaznická podpora@singerindia.com
- Webmísto: www.singerindia.com
- Adresa: Singer India Limited, Institute for Studies in Industrial Development (ISID), 3rd Floor, Block C-2-3, ISID Campus, 4, Vasant Kunj Institutional Area, New Delhi – 110070