Sloan EBV129A-U

Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module for Urinal User Manual

Model: EBV129A-U

1. Úvod

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module for Urinals. This module is designed to provide reliable, hands-free flushing for G2 Optima Plus flushometers, enhancing hygiene and water conservation in commercial and public restrooms.

2. Bezpečnostní informace

Please read all safety instructions before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or improper product function.

  • Před zahájením jakékoli instalace nebo údržby vždy vypněte přívod vody.
  • Ensure all electrical connections are made by a qualified electrician if applicable, and comply with local codes.
  • Používejte vhodné osobní ochranné prostředky (OOP), jako jsou ochranné brýle a rukavice.
  • Do not attempt to modify the product. Use only genuine Sloan replacement parts.
  • Udržujte děti mimo oblast instalace.

3. Obsah balení

Před zahájením instalace ověřte, zda jsou všechny komponenty přítomny:

  • Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module
  • Montážní hardware (pokud je k dispozici)
  • Pokyny k použití (tento dokument)

Note: Additional components for the complete flushometer system are sold separately.

4. Nastavení a instalace

Installation should be performed by a qualified plumber or technician.

  1. Prepare the Urinal: Ensure the urinal and existing flushometer body are clean and free of debris. Turn off the main water supply to the urinal.
  2. Odebrat stávající komponenty: Carefully remove any old sensor modules or manual flush handles from the flushometer.
  3. Install the Sensor Module: Position the EBV129A-U module onto the flushometer body according to the specific G2 Optima Plus flushometer model's instructions. Ensure proper alignment and secure attachment.
  4. Připojte kabeláž (pokud je k dispozici): If the module requires external power or data connections, connect them securely following the wiring diagram provided with your specific flushometer model. Ensure all connections are watertight.
  5. Obnovení zásobování vodou: Pomalu zapněte přívod vody a zkontrolujte těsnost.
  6. Testovací provoz: Allow the sensor to calibrate for a few moments. Step away from the urinal, then approach it to trigger the sensor. The flushometer should activate automatically.
Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module for Urinal

Obrázek 1: Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module. This image shows the compact electronic sensor module, typically installed on a urinal flushometer to enable automatic, hands-free flushing. It features a sensor window and connection points for integration with the flushometer system.

5. Návod k obsluze

The Sloan EBV129A-U G2 Optima Plus Electronic Sensor Module provides fully automatic, hands-free operation for urinals equipped with compatible G2 Optima Plus flushometers.

  • Automatické splachování: The sensor detects the user's presence and initiates a flush cycle after the user departs.
  • Dosah senzoru: The sensor is factory-set for optimal detection range. Avoid placing objects directly in front of the sensor that could obstruct its view or cause false activations.
  • Manual Override (if applicable): Some G2 Optima Plus flushometers may feature a manual override button. Refer to your specific flushometer's manual for details on this function.

6. Údržba

Regular maintenance ensures optimal performance and longevity of your sensor module.

  • Čištění: Clean the sensor lens regularly with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the sensor surface.
  • Battery Replacement (if battery-powered): If your G2 Optima Plus flushometer system uses batteries for the sensor module, replace them as indicated by a low battery indicator or when the flushometer stops responding. Refer to your flushometer's manual for specific battery type and replacement procedures.
  • Inspekce: Periodically inspect the module for any signs of damage or loose connections.

7. Řešení problémů

If you experience issues with your sensor module, consult the following table before contacting support.

ProblémMožná příčinaŘešení
No flush when user departsObstructed sensor lens, low battery (if applicable), water supply off, faulty module.Clean sensor lens. Replace batteries. Check water supply valve. Contact Sloan support if problem persists.
Nepřetržité proplachováníSensor obstruction, faulty sensor, internal flushometer issue.Remove any objects near sensor. Check for reflective surfaces. Consult flushometer manual. Contact Sloan support.
Slabé nebo neúplné spláchnutíLow water pressure, partially closed stop valve, flushometer diaphragm issue.Check water pressure. Ensure stop valve is fully open. Consult flushometer manual for diaphragm inspection.

8. Specifikace

  • Číslo modelu: DT-39901 (EBV129A-U)
  • Značka: Sloan
  • Materiál: Kov
  • Vnější úprava: Nerez
  • Velikost vstupního připojení: 1 palce
  • Typ vstupního připojení: Příruba
  • Velikost výstupního připojení: 2 palce
  • Typ výstupního připojení: Typ připojení ventilu
  • Počet portů: 2
  • Typ ventilu: Kulový ventil
  • Velikost: 1 palce x 2 palce
  • Hmotnost položky: 0.01 uncí
  • Specifikace splněna: CSA, ULC
  • UPC: 733353562306

9. Záruka a podpora

Sloan products are manufactured to the highest standards and are backed by a limited warranty. For specific warranty details, please refer to the warranty information included with your original flushometer purchase or visit the official Sloan webmísto.

For technical assistance, replacement parts, or further inquiries, please contact Sloan Customer Support:

  • Webmísto: www.sloan.com