Bryant BD20/20

Uživatelská příručka k jističi BRYANT BD20/20

Model: BD20/20

1. Úvod

This manual provides essential information for the safe installation, operation, and maintenance of the BRYANT BD20/20 20A 120/240V 2P 10K Circuit Breaker. This device is designed to protect electrical circuits from overcurrent conditions, such as overloads and short circuits, by automatically interrupting the flow of electricity. Please read this manual thoroughly before installation or use to ensure proper function and safety.

2. Bezpečnostní informace

VAROVÁNÍ: Electrical shock hazard. Installation and servicing of this circuit breaker must be performed by qualified personnel only. Always disconnect power at the main service panel before working on electrical circuits.

  • Během instalace se ujistěte, že jsou dodržovány všechny místní a národní elektrotechnické předpisy.
  • Ověřte svtage and current ratings of the circuit breaker match the requirements of the electrical system.
  • Do not install or operate the circuit breaker if it appears damaged.
  • Používejte vhodné osobní ochranné prostředky (OOP), včetně izolačních rukavic a ochranných brýlí.
  • Nikdy neobcházejte aniamps ochrannými mechanismy jističe.

3. Konec produktuview

The BRYANT BD20/20 is a 2-pole, 20-amp circuit breaker designed for 120/240V applications. It features a 10,000 Ampere Interrupting Capacity (AIC), indicating its ability to safely interrupt high fault currents. The breaker is designed for plug-in mounting in compatible load centers.

Přední view of the BRYANT BD20/20 circuit breaker with red ON/OFF toggles.
Obrázek 3.1: Přední strana View of BD20/20 Circuit Breaker
This image displays the front of the BRYANT BD20/20 circuit breaker. It clearly shows the two red toggle switches, labeled "ON" and "OFF" for each pole. The brand "BRYANT" and model "BD20-20" are visible, along with "CU-AL SWD" indicating compatibility with copper and aluminum wiring. The UL listing information is also present at the top.
Dno view of the BRYANT BD20/20 circuit breaker showing patent numbers and 'MADE IN U.S.A.'.
Obrázek 3.2: Spodní část View of BD20/20 Circuit Breaker
This image shows the bottom side of the BRYANT BD20/20 circuit breaker. Visible markings include "USE ONLY IN LISTED ENCLOSURE", "40 C CPL 60/75 C WIRE", and several patent numbers. The text "MADE IN U.S.A." is also clearly visible, indicating the country of manufacture.
Nahoru view of the BRYANT BD20/20 circuit breaker showing torque specifications and current interrupting rating.
Obrázek 3.3: Nahoře View of BD20/20 Circuit Breaker
This image displays the top side of the BRYANT BD20/20 circuit breaker. Key information includes the "TORQUE" specifications for wire connections: 14-10 AWG 20 IN.LBS., 8 AWG 25 IN.LBS., and 6-4 AWG 27 IN.LBS. The "CURRENT INTERRUPTING RATING" is also shown as "MAX. RMS SYM. AMPERES 10,000 AT 120/240 VOLTS AC".

4. Nastavení a instalace

DŮLEŽITÉ: Ensure all power to the electrical panel is OFF before proceeding with installation. Use a voltage tester to confirm the absence of power.

  1. Odpojení napájení: Locate the main service panel and turn off the main breaker to completely de-energize the panel.
  2. Přístup k panelu: Carefully remove the cover of the electrical panel to expose the bus bar and wiring.
  3. Umístění jističe: Identify an available slot on the bus bar that is compatible with the BD20/20's plug-in design.
  4. Instalace: Align the circuit breaker with the bus bar and firmly push it into place until it clicks securely. Ensure both poles are properly seated.
  5. Zapojení: Connect the circuit wires to the appropriate terminals on the circuit breaker. For the BD20/20, connect the two hot wires to the respective screw terminals. Refer to Figure 3.3 for recommended torque specifications for wire gauges (14-10 AWG: 20 in-lbs, 8 AWG: 25 in-lbs, 6-4 AWG: 27 in-lbs).
  6. Zabezpečená připojení: Tighten the terminal screws to the specified torque to ensure a secure and safe electrical connection.
  7. Znovumontování panelu: Replace the electrical panel cover, ensuring all screws are tightened.
  8. Obnovení napájení: Turn the main breaker back ON at the service panel.
  9. Testování: Test the circuit protected by the newly installed breaker to confirm proper operation.

5. Návod k obsluze

The BRYANT BD20/20 circuit breaker operates with simple ON/OFF toggles. When the circuit breaker trips due to an overload or short circuit, the toggle will move to a central or "tripped" position, typically between ON and OFF.

  • Zapnout: Push the red toggle(s) firmly to the "ON" position.
  • Vypnout: Push the red toggle(s) firmly to the "OFF" position.
  • Resetování vypnutého jističe: First, push the toggle(s) completely to the "OFF" position. Then, push the toggle(s) firmly to the "ON" position. If the breaker immediately trips again, there may be a persistent fault in the circuit that requires professional attention.

6. Údržba

Circuit breakers like the BRYANT BD20/20 are generally maintenance-free. However, periodic visual inspection is recommended.

  • Roční kontrola: Annually, or as required by local codes, have a qualified electrician inspect the circuit breaker and its connections for any signs of wear, corrosion, or overheating (discoloration).
  • Čištění: Ensure the area around the circuit breaker within the panel is free from dust and debris. Do not use liquids for cleaning inside the electrical panel.
  • Testování: While not typically required for residential breakers, some commercial or industrial applications may require periodic testing by a qualified professional.

7. Řešení problémů

ProblémMožná příčinaŘešení
Přerušovač často vypíná.Přetížený obvod, zkrat nebo zemní spojení.Reduce load on the circuit. Unplug appliances. Inspect wiring for damage. If problem persists, consult a qualified electrician.
Jistič se neresetuje.Persistent fault (short circuit/ground fault) or internal breaker damage.Ensure the toggle is pushed fully to "OFF" before attempting to reset to "ON". If it still won't reset, do not force it. Call a qualified electrician.
No power to circuit after installation.Breaker not fully seated, loose wiring connections, or main power off.Verify main breaker is ON. Ensure the BD20/20 is fully seated on the bus bar. Check wire connections for tightness (with power OFF).

If you are unable to resolve an issue, or if you suspect a serious electrical problem, always contact a qualified and licensed electrician.

8. Specifikace

AtributHodnota
Číslo modeluBD20/20
ZnačkaBryant
Aktuální hodnocení20 Amps
svtage Hodnocení120 / 240V AC
Počet pólů2
Interrupting Capacity (AIC)10,000 Amperes
Typ montážePlug-In Mount
Typ jističeNorma
Rozměry produktu3 x 1 x 3 palce
Hmotnost5.86 unce

9. Záruka a podpora

Specific warranty information for the BRYANT BD20/20 circuit breaker is typically provided by the manufacturer or the point of purchase. Please refer to the documentation included with your purchase or contact Bryant customer support for details regarding warranty coverage and terms.

For technical support or inquiries, please contact Bryant customer service or a certified electrician.

© 2024 Bryant. All rights reserved. Information subject to change without notice.