Viessmann 7828718

VIESSMANN VITODENS 100 WB1C Ignition Electrode KIT

Návod k použití

1. Úvod

This manual provides essential information regarding the Viessmann Vitodens 100 WB1C Ignition Electrode Kit (Part Number 7828718). This kit is a critical component for the reliable operation of Viessmann Vitodens 100 WB1C Combi boilers, specifically models with 26KW, 30KW, and 35KW capacities. It is designed to ensure proper ignition and flame sensing within the boiler's combustion chamber.

Please read this manual carefully before attempting any installation or maintenance. For safety and optimal performance, installation and servicing should only be performed by a qualified and certified heating engineer.

2. Popis produktu

The Viessmann Ignition Electrode Kit 7828718 is a high-quality replacement part essential for the ignition and ionization process in compatible Viessmann Vitodens 100 WB1C boilers. This kit typically includes the ignition/ionization electrode, mounting screws, and a gasket, ensuring a complete and secure replacement.

Viessmann Vitodens 100 WB1C Ignition Electrode Kit components

Obrázek 2.1: Nadview of the Viessmann Ignition Electrode Kit, showing the electrode, mounting screws, and gasket.

The electrode is responsible for generating the spark required to ignite the gas-air mixture in the combustion chamber and for sensing the presence of a flame (ionization). A properly functioning electrode is crucial for the boiler's safe and efficient operation.

Detailní záběr view of the Viessmann ignition electrode

Obrázek 2.2: Detailní view of the ignition electrode, highlighting its ceramic insulation and metal prongs.

Strana view of the Viessmann ignition electrode showing connection point

Obrázek 2.3: Another perspective of the electrode, showing the connection terminal and mounting plate.

3. Nastavení a instalace

Důležité bezpečnostní upozornění: Installation of this component involves working with gas appliances and electrical connections. Incorrect installation can lead to serious injury, property damage, or death. Always ensure the boiler is isolated from the main power supply and gas supply before commencing any work. This procedure should only be carried out by a Gas Safe registered engineer or equivalent qualified professional.

  1. Příprava: Ensure the boiler is switched off, isolated from the electrical supply, and the gas supply is turned off at the main isolation valve. Allow the boiler to cool down if it has been recently operating.
  2. Přístup: Opatrně vyjměte kotel casing and locate the existing ignition electrode assembly. Refer to the specific boiler's service manual for exact location and access procedures.
  3. Odpojení: Disconnect the electrical lead from the existing electrode. Note its orientation and connection points.
  4. Odstranění: Unscrew and carefully remove the old electrode assembly. Be mindful of any existing gaskets or seals.
  5. Inspekce: Inspect the area for any debris or damage. Clean as necessary.
  6. Instalace nové elektrody: Place the new gasket (if supplied) onto the new electrode. Carefully insert the new electrode into its position, ensuring correct alignment. Secure it with the new mounting screws provided in the kit. Do not overtighten.
  7. Spojení: Reconnect the electrical lead to the new electrode, ensuring a secure and correct connection.
  8. Opětovná montáž: Replace the boiler casing.
  9. Testování: Restore gas and electrical supply. Follow the boiler manufacturer's instructions for commissioning and testing the boiler to ensure proper ignition and safe operation. Check for gas leaks if any gas connections were disturbed.

4. Provoz

The ignition electrode is an integral part of the boiler's ignition sequence. When a demand for heat or hot water is initiated, the boiler's control system sends a signal to the gas valve to open and to the ignition electrode to generate a high-voltage spark. This spark ignites the gas-air mixture in the combustion chamber.

Once the flame is established, the same electrode often functions as an ionization probe. It detects the presence of the flame by sensing a small electrical current that passes through the flame itself. This ionization current signals to the boiler's control board that ignition has been successful and the flame is stable, allowing the boiler to continue its operation. If no flame is detected within a specified timeframe, the boiler will typically enter a lockout state for safety.

5. Údržba

Regular maintenance is crucial for the longevity and efficient operation of your boiler and its components, including the ignition electrode. It is recommended that your boiler undergoes an annual service by a qualified heating engineer.

6. Řešení problémů

If your boiler is experiencing ignition issues, the ignition electrode could be a contributing factor. Below are common symptoms and potential causes related to the electrode. Always consult a qualified heating engineer for diagnosis and repair. Do not attempt to troubleshoot or repair gas appliances yourself.

A qualified engineer will use specialized tools to test the electrode's resistance and ionization current, and inspect its physical condition to determine if replacement is necessary.

7. Technické specifikace

AtributDetail
Typ produktuIgnition/Ionization Electrode Kit
ZnačkaViessmann
Kompatibilita modeluViessmann Vitodens 100 WB1C Combi (26KW, 30KW, 35KW)
Číslo dílu7828718
VýrobceVIESSMANN
ASINB01J3PJTTA
Jsou vyžadovány baterieŽádný
Datum první dostupnosti26. července 2016

8. Záruka a podpora

For information regarding the warranty of your Viessmann Ignition Electrode Kit 7828718, please refer to the warranty documentation provided with your original boiler or contact Viessmann directly. Warranty terms typically cover manufacturing defects.

For technical support, installation queries, or professional servicing, please contact a qualified Gas Safe registered engineer (or equivalent national standard) or the official Viessmann customer support in your region. Do not attempt to repair or modify the product yourself, as this may void the warranty and pose safety risks.

You may also contact the seller, Hanicks Heating & Spares, for purchase-related inquiries.