VELIKOST 2871-101

INSIZE 2871-101 Electronic Thickness Gage

Uživatelská příručka

Model: 2871-101 | Brand: INSIZE

1. Konec produktuview

The INSIZE 2871-101 Electronic Thickness Gage is a precision measuring instrument designed for accurately determining the thickness of various materials. It features a digital display for clear readings and user-friendly controls for efficient operation.

Klíčové vlastnosti:

  • Ceramic spindle tip and anvil for durability and precision.
  • Intuitive buttons for On/Off, Zero, and Inch/Millimeter unit conversion.
  • Powered by a CR2032 battery with automatic power-off function to conserve energy.
  • Data output capability for advanced applications.

2. Nastavení

Before using your INSIZE Electronic Thickness Gage, please follow these setup instructions:

2.1. Instalace baterie

The gage requires one CR2032 button cell battery. Ensure proper polarity when inserting.

  1. Locate the battery compartment cover, typically on the back or side of the display unit.
  2. Use a small coin or screwdriver to gently open the battery compartment.
  3. Vložte baterii CR2032 kladným pólem (+) nahoru.
  4. Bezpečně zavřete kryt bateriového prostoru.
INSIZE 2871-101 Electronic Thickness Gage in its protective case with a CR2032 battery visible.

Figure 1: The INSIZE 2871-101 Electronic Thickness Gage shown in its protective case, with the CR2032 battery ready for installation. This image illustrates the product's packaging and initial setup components.

2.2. Initial Power On and Zeroing

After battery installation, power on the device and perform an initial zeroing.

  1. Stiskněte tlačítko ON/OFF button to turn on the gage. The display should light up.
  2. Ensure the spindle tip and anvil are clean and free of debris.
  3. Gently close the spindle tip onto the anvil until they make contact.
  4. Stiskněte tlačítko NULA button. The display should now read 0.0000 or 0.000. If it does not, repeat the process.

3. Návod k obsluze

Follow these steps to take accurate measurements with your thickness gage:

3.1. Měření

  1. Ensure the gage is powered on and zeroed as described in Section 2.2.
  2. Gently lift the spindle lever to open the measuring jaws.
  3. Carefully insert the material to be measured between the ceramic spindle tip and the anvil.
  4. Release the spindle lever slowly, allowing the tip to rest firmly on the material without applying excessive force.
  5. Read the thickness value displayed on the digital screen.
Přední view of the INSIZE 2871-101 Electronic Thickness Gage, showing its digital display, buttons, and measuring jaws.

Figure 2: The INSIZE 2871-101 Electronic Thickness Gage in operation, highlighting its digital display and ergonomic design for precise measurements.

3.2. Změna měrných jednotek

The gage can display measurements in both inches and millimeters.

  • Stiskněte tlačítko IN/MM button to toggle between inch (in) and millimeter (mm) units. The current unit will be indicated on the display.

3.3. Vypněte

To turn off the gage, press and hold the ON/OFF button until the display turns off. The gage also features an automatic power-off function after a period of inactivity to save battery life.

4. Údržba

Proper maintenance ensures the longevity and accuracy of your thickness gage.

4.1. Čištění

  • Wipe the gage body with a soft, dry cloth.
  • For the ceramic spindle tip and anvil, use a clean, lint-free cloth. Avoid using abrasive cleaners or solvents, as they may damage the surfaces.
  • Ensure no dust or debris accumulates on the measuring surfaces.

4.2. Výměna baterie

When the display becomes dim or the gage does not power on, it's time to replace the battery. Refer to Section 2.1 for battery installation instructions.

4.3. Skladování

  • Store the gage in its original protective case when not in use.
  • Keep the gage in a dry environment, away from direct sunlight, extreme temperatures, and high humidity.
  • Avoid storing in areas with excessive dust or corrosive chemicals.
The INSIZE 2871-101 Electronic Thickness Gage stored securely in its closed protective case.

Figure 3: The INSIZE 2871-101 Electronic Thickness Gage safely enclosed in its protective case, demonstrating proper storage for long-term preservation and protection.

5. Řešení problémů

If you encounter issues with your INSIZE Electronic Thickness Gage, refer to the following common problems and solutions:

ProblémMožná příčinaŘešení
Displej se nezapne.Vybitá nebo nesprávně nainstalovaná baterie.Vyměňte baterii CR2032 a dbejte na správnou polaritu.
Nepřesné údaje.Gage not zeroed; debris on measuring surfaces; damaged spindle/anvil.Re-zero the gage; clean spindle tip and anvil; inspect for damage. If damaged, contact support.
Na displeji se zobrazuje „E“ nebo chybový kód.Internal error; low battery.Replace battery; turn off and restart the gage. If error persists, contact manufacturer support.
Tlačítka nereagují.Low battery; internal malfunction.Replace battery. If issue continues, contact manufacturer support.

6. Specifikace

Detailed technical specifications for the INSIZE 2871-101 Electronic Thickness Gage:

SpecifikaceHodnota
Číslo modelu2871-101
Rozsah měření0 - 0.4 palce (0 - 10 mm)
Rezoluce0.00005 palce (0.001 mm)
Přesnost měření+/-0.00005 inches
Material (Spindle Tip & Anvil)Keramický
Typ baterieCR2032
Výstup datAno

7. Záruka a podpora

For warranty information and technical support, please refer to the official INSIZE webnebo se obraťte na autorizovaného prodejce. Uschovejte si účtenku jako doklad o koupi.

Výrobce: VE VELIKOSTI

For further assistance, visit the official INSIZE webnebo kontaktujte jejich oddělení zákaznických služeb.

© 2023 INSIZE. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.