The Kidde i12060 is an AC-powered, hardwired ionization smoke alarm designed to provide early warning of smoke and fire. This alarm features a front-loading battery backup for continuous operation during power outages and a hush feature to temporarily silence nuisance alarms. It is designed for residential use and can interconnect with up to 24 compatible Kidde devices.
Důležité bezpečnostní informace
Please read this manual thoroughly before installation and operation. Keep this manual for future reference. This device detects smoke particles. It does not detect heat, flames, or carbon monoxide. For complete fire safety, ensure your home has both smoke and carbon monoxide alarms.
VAROVÁNÍ: This product can expose you to chemicals including Styrene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, refer to www.P65Warnings.ca.gov.
Nastavení a instalace
Obsah balení:
- One Kidde i12060 120-volt AC wire-in smoke alarm
- One 9-volt battery
- Návod k obsluze a instalaci
Location Guidelines:
- Install smoke alarms on every level of your home, inside each bedroom, and outside each sleeping area.
- Avoid installing near windows, doors, or forced-air vents where drafts could interfere with smoke detection.
- Do not install in kitchens, garages, or furnace rooms where combustion particles are normally present, as this may cause nuisance alarms.
- Konkrétní požadavky na instalaci naleznete v místních stavebních předpisech.
Wiring and Mounting:
- Vypnout: Ensure power to the circuit is turned off at the main fuse box or circuit breaker.
- Připojení kabeláže: The alarm comes with a pre-stripped wiring harness with tinned strands. Connect the appropriate wires (black to hot, white to neutral, orange to interconnect if applicable) to your household wiring using wire nuts.
- Připevněte montážní držák: Secure the mounting bracket to the ceiling or wall using the provided screws. The large mounting base helps cover imperfections.
- Nainstalujte baterii: Open the front battery door and insert the included 9-volt battery. Ensure the battery pull tab is removed to activate the battery. The front-loading battery door allows for easy battery replacement without removing the alarm from its base.
- Připevnění alarmu k držáku: Zarovnejte alarm s montážním držákem a otáčejte jím ve směru hodinových ručiček, dokud nezapadne na místo.
- Obnovit napájení: Turn the power back on at the main fuse box or circuit breaker.
- Testovací alarm: Press and hold the test button for a few seconds until the alarm sounds. This confirms proper operation.

Figure 1: Kidde i12060 Hardwired Smoke Detector Alarm. This image shows the complete smoke alarm unit, highlighting its compact design and the front-loading battery compartment.
Návod k obsluze
Normální provoz:
During normal operation, the red LED indicator will flash approximately once every 30-40 seconds, indicating that the alarm is receiving power and functioning correctly.
Testování alarmu:
Test the alarm weekly by pressing and holding the "Push and Hold to Test" button. The alarm will sound a loud, pulsating horn. Release the button to stop the alarm. This tests the unit's electronic circuitry, horn, and battery.

Figure 2: A person pressing the test button on a ceiling-mounted Kidde smoke detector. This demonstrates the simple action required to test the alarm's functionality.
Hush Feature:
The hush feature temporarily silences nuisance alarms caused by non-emergency situations like cooking smoke. To activate, press the "Hush" button. The alarm will be desensitized for approximately seven minutes. During this time, the alarm will chirp every 30 to 40 seconds. If smoke density is too high, the hush feature will be overridden, and the alarm will sound. The alarm automatically resets after seven minutes.
Údržba
Výměna baterie:
The 9-volt battery provides backup power during outages. Replace the battery at least once a year, or immediately when the alarm chirps approximately once a minute (indicating a low battery). To replace, open the front battery door, remove the old battery, and insert a new 9-volt battery. Close the battery door securely.
Čištění alarmu:
Clean your smoke alarm at least once a month to remove dust and debris. Use a soft brush or a vacuum cleaner with a soft brush attachment to clean the exterior of the alarm and the openings. Do not paint the alarm.
Odstraňování problémů
| Problém | Možná příčina | Řešení |
|---|---|---|
| Alarm chirps once every minute | Slabá baterie | Vyměňte 9voltovou baterii. |
| Nuisance alarms (false alarms) | Cooking smoke, steam, dust, high humidity | Use the hush feature. Relocate the alarm if nuisance alarms persist due to environmental factors. Clean the alarm. |
| Během testu se nespustí alarm | Žádné napájení, vybitá baterie, vadný přístroj | Check power supply. Replace battery. If still not working, replace the unit. |
| Budík zní nepřetržitě | Presence of smoke/fire, or unit malfunction | Evacuate immediately if smoke/fire is present. If no smoke/fire, use hush feature or replace unit if malfunction persists. |
Specifikace
- Model: i12060
- Metoda detekce: Ionizace
- Zdroj napájení: 120VAC, 9V Battery Backup
- Zvukové upozornění: 85dB @ 10 ft. Horn
- Vizuální upozornění: Červená LED
- Průměr: 5 palců
- Výška: 1-3/4 palce
- Interconnection Capability: Až 24 jednotek
- Tlačítko umlčení: Ano
- Testovací tlačítko: Ano
- Locking Pin: Ano
- Provozní teplota: 40 °F až 100 °F (4.4 °C až 37.8 °C)
- standardy: Seznam UL
- Záruka výrobce: 10 rok omezená záruka
- GTIN: 047871260546
- Model Number (Mfr Part Number): 21026054
Informace o záruce
The Kidde i12060 smoke alarm comes with a 10-year limited warranty from the manufacturer. For detailed warranty terms and conditions, please refer to the documentation included with your product or contact Kidde customer support.
Podpora a kontakt
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Kidde customer support. For comprehensive fire preparedness information and local safety guidelines, contact your local fire department.