Zavedení
This manual provides comprehensive instructions for the installation, operation, and maintenance of your NuTone Roomside Series AERN80K Ventilation Fan. Please read these instructions carefully before beginning installation or operation to ensure proper function and safety. Keep this manual for future reference.

This image displays the NuTone Roomside Series Ventilation Fan. It features a white, low-profile CleanCover grille and a black duct connector extending from the side of the housing. The fan is designed for discreet integration into ceilings.
Bezpečnostní informace
Always follow basic safety precautions when installing, operating, or maintaining this product to reduce the risk of fire, electric shock, or injury to persons.
- Před instalací nebo servisem odpojte napájení na servisním panelu.
- All wiring must comply with local electrical codes and standards.
- Tato jednotka je určena pouze pro všeobecné použití při větrání. Nepoužívejte ji k odsávání nebezpečných nebo výbušných materiálů a par.
- Abyste předešli poškození motoru a hlučným/nevyváženým oběžným kolům, chraňte pohonnou jednotku před stříkanými materiály od sádrokartonu, stavebním prachem a dalšími nečistotami.
- This fan is UL listed for use over bathtubs or showers when connected to a GFCI-protected branch circuit.
- This fan is UL listed for use in insulated ceilings (Type I.C.).
Obsah balení
Před zahájením instalace ověřte, zda jsou všechny komponenty přítomny:
- Ventilation Fan Housing Assembly
- CleanCover Grille
- SnapFit Flange Kit
- EzDuct Connector
- Mounting Ears (FoldAway)
- Šablona instalace
- Uživatelská příručka (tento dokument)
Nastavení a instalace
The NuTone Roomside Series AERN80K fan is designed for flexible installation, including retrofit, remodel, and replacement applications, particularly in spaces without attic access. Installation can be performed entirely from the room side.
Klíčové vlastnosti instalace:
- Room-Side Access: The fan can be installed without requiring access to the attic, simplifying the process for existing structures.
- Instalační šablona: Use the provided template for accurate ceiling opening cuts.
- SnapFit Flange Kit: This kit provides a self-trimming finish, covering any rough edges of the ceiling opening for a clean appearance.
- EzDuct Connector: Designed for room-side connection to ductwork, ensuring an airtight seal.
- FoldAway Mounting Ears: These adjustable ears facilitate easy and secure installation in various ceiling constructions.
- Elektrické připojení: Ensure all electrical connections are made by a qualified electrician and comply with local codes. The unit requires a 120V power supply.
For detailed step-by-step instructions, refer to the included installation guide or visit the official NuTone support webmísto.
Návod k obsluze
The NuTone AERN80K Ventilation Fan is designed for efficient and quiet operation to remove moisture and odors from your bathroom or other designated areas.
- Zapnutí/vypnutí: The fan is typically controlled by a standard wall switch (Push Button type). Flip the switch to turn the fan on or off.
- Proud vzduchu: The fan operates at 80 Cubic Feet per Minute (CFM), providing effective ventilation for rooms up to 75 sq. ft.
- Tichý provoz: With a noise level of 0.7 Sones, the fan operates quietly, minimizing disruption.
- Pokročilý motor: The brushless DC electronically controlled digital motor offers high efficiency compared to standard AC motors.
- Inteligentní ovládání (volitelné): This model is compatible with the Overture Connected IAQ System, allowing for potential app-based control and integration with smart home systems. Refer to the Overture system documentation for setup and usage details if applicable.
For optimal performance, operate the fan during and after activities that generate moisture, such as showering or bathing, to ensure proper ventilation.
Údržba
Regular maintenance ensures the longevity and efficient operation of your NuTone AERN80K Ventilation Fan.
- Čištění mřížky: The CleanCover grille is designed with fewer vent slots to reduce dust accumulation. To clean, gently pull down the grille to detach it from the housing. Wipe the grille with a soft, damp cloth and mild detergent. Ensure it is completely dry before reattaching.
- Čištění lopatek ventilátoru: Periodically, with power disconnected, carefully wipe the fan blades with a damp cloth to remove any accumulated dust or debris. Avoid bending the blades.
- Motor: The motor is permanently lubricated and requires no additional oiling.
- Potrubí: Inspect ductwork periodically for obstructions or leaks. Ensure the EzDuct connector maintains an airtight seal.
Always disconnect power to the fan at the circuit breaker before performing any cleaning or maintenance.
Odstraňování problémů
If your NuTone AERN80K Ventilation Fan is not operating as expected, consult the following common issues and solutions:
| Problém | Možná příčina | Řešení |
|---|---|---|
| Ventilátor se nezapne. | Jednotka není napájena. Vadný nástěnný vypínač. Uvolněné připojení kabeláže. | Zkontrolujte jistič. Vyzkoušejte nebo vyměňte spínač. Zkontrolujte, zda jsou všechna kabelová připojení bezpečná (při vypnutém napájení). |
| Ventilátor je hlučný. | Volná montáž. Nečistoty v lopatkách ventilátoru. Poškozené oběžné kolo. | Ensure fan housing is securely mounted. Disconnect power and clean blades. Contact customer support if impeller is damaged. |
| Špatný pohyb vzduchu. | Blocked ductwork. Dirty grille or fan blades. Improper fan size for room. | Check ductwork for obstructions. Clean grille and fan blades. Ensure fan CFM matches room size requirements. |
If troubleshooting steps do not resolve the issue, please contact NuTone customer support.
Specifikace
| Značka | Nutone |
| Číslo modelu | AERN80K |
| Proud vzduchu | 80 CFM (kubických stop za minutu) |
| Úroveň hluku | 0.7 Sones |
| Wattage | 36 wattů |
| svtage | 120 voltů |
| Typ pokoje | Bathroom (up to 75 sq. ft.) |
| Typ instalace | Room-side |
| Typ motoru | Brushless DC Electronically Controlled Digital Motor |
| Účinnost | ENERGY STAR Certified, High Efficiency |
| Certifikace | UL Listed (for use over bathtubs/showers with GFCI, and in insulated ceilings Type I.C.), HVI-2100 Certified, Title 24 Compliant |
| UPC | 026715257713 |
| Rozměry balení | 13.5 x 13.4 x 10.6 palce |
| Hmotnost položky | 9.03 libry |
Informace o záruce
NuTone products are manufactured to the highest quality standards and are warranted to be free from defects in material and workmanship for a specified period from the date of original purchase. For specific warranty terms and conditions applicable to the AERN80K model, please refer to the warranty card included with your product or visit the official NuTone webUschovejte si doklad o koupi pro případ reklamace.
Podpora
For technical assistance, replacement parts, or further information regarding your NuTone Roomside Series AERN80K Ventilation Fan, please contact NuTone Customer Service:
- Webmísto: Visit the official NuTone webweb s častými dotazy, registrací produktů a zdroji podpory.
- Telefon: Refer to the contact information provided on the NuTone webwebu nebo obalu vašeho produktu, kde najdete telefonní čísla zákaznických služeb.
- When contacting support, please have your model number (AERN80K) and date of purchase available.