1. Konec produktuview
The Kohler 1021119 is a genuine replacement part designed for specific Kohler faucet systems. This component is a 1/2 inch thermostatic valve cartridge, essential for regulating water temperature and flow within your plumbing fixture. It is constructed from durable brass and features a standard threaded connection for reliable performance.

Image 1.1: The Kohler 1021119 Thermostatic Valve Cartridge. This image displays the brass cartridge, which is a key component for temperature regulation in compatible Kohler faucets.
2. Vlastnosti produktu
- Náhradní kazeta: Specifically designed as a direct replacement for compatible Kohler thermostatic valves.
- 1/2 Inch Thermostatic Valve: Ensures precise control over water temperature, preventing sudden changes.
- Odolná mosazná konstrukce: Manufactured from high-quality brass for longevity and resistance to corrosion.
- No Finish: The cartridge is supplied without an external finish, as it is an internal component.
- Číslo modelu: Identified as Kohler Model 1021119.
3. Nastavení a instalace
Installation of the Kohler 1021119 thermostatic valve cartridge requires basic plumbing knowledge and tools. It is recommended to consult the specific installation guide for your Kohler faucet model, as procedures may vary. Always ensure the main water supply is turned off before beginning any installation or replacement work.
- Vypněte přívod vody: Locate the main water shut-off valve for your home or the specific fixture and turn it off. Open the faucet to drain any remaining water.
- Přístup k kazetě: Depending on your faucet model, you may need to remove handles, escutcheons, or other decorative components to access the existing cartridge.
- Vyjměte starou kazetu: Carefully remove the old thermostatic cartridge. This may involve unscrewing a retaining nut or clip. Note the orientation of the old cartridge for correct installation of the new one.
- Instalace nové kazety: Insert the new Kohler 1021119 cartridge into the valve body, ensuring it is correctly seated and oriented. Secure it with the retaining nut or clip.
- Znovu sestavte kohoutek: Reattach any handles, escutcheons, or other components removed in step 2.
- Obnovení zásobování vodou: Slowly turn the main water supply back on and check for leaks. Test the faucet's temperature and flow control.
Poznámka: If you are unsure about any step, it is advisable to contact a qualified plumber.
4. Návod k obsluze
The Kohler 1021119 thermostatic valve cartridge operates internally within your faucet to maintain a consistent water temperature. Once installed, its function is automatic. Users interact with the faucet's external controls (handles or levers) to select the desired temperature and flow. The cartridge then mixes hot and cold water to achieve and maintain that temperature, even if incoming water pressure or temperature fluctuates.
- Ovládání teploty: Adjust the faucet handle to select the desired water temperature. The thermostatic cartridge will automatically blend hot and cold water to reach and maintain this setting.
- Řízení toku: Use the faucet handle to control the water flow rate as needed.
5. Údržba
The Kohler 1021119 thermostatic valve cartridge is designed for long-term reliability with minimal maintenance. However, water quality can affect its lifespan. Regular maintenance of your plumbing system can help ensure optimal performance.
- Kvalita vody: In areas with hard water, mineral deposits can accumulate over time. If you notice a decrease in temperature control or flow, the cartridge may need cleaning or replacement.
- Čištění: If cleaning is required, carefully remove the cartridge as per the installation steps and gently rinse it under clean water. Avoid using harsh chemicals or abrasive tools that could damage the internal components.
- Nahrazení: If the cartridge is damaged or no longer functions correctly after cleaning, it should be replaced with a new Kohler 1021119 unit.
6. Řešení problémů
If you experience issues with your faucet after installing or while using the Kohler 1021119 thermostatic valve cartridge, consider the following common troubleshooting steps:
- Nekonzistentní teplota vody:
- Ensure both hot and cold water supplies are fully open.
- Check if the cartridge is properly seated and secured.
- Mineral buildup might be affecting the cartridge's function. Consider cleaning or replacing the cartridge.
- Nízký průtok vody:
- Verify that the main water supply and any shut-off valves for the fixture are fully open.
- Inspect the cartridge for any obstructions or debris.
- Check the aerator on the faucet spout for clogs.
- Leaks Around the Faucet Handle:
- Ensure all connections and retaining nuts are tightened appropriately (do not overtighten).
- Check the O-rings and seals on the cartridge for damage or improper seating.
For persistent issues, refer to your specific faucet model's manual or contact Kohler customer support.
7. Specifikace
| Atribut | Detail |
|---|---|
| Číslo modelu | 1021119 |
| Značka | Kohler |
| Typ součásti | Thermostatic Valve Cartridge |
| Materiál | Mosaz |
| Velikost vstupního připojení | 0.5 palce |
| Velikost závitu | 1/2 palce |
| Typ konektoru | Se závitem |
| Počet portů | 2 |
| Rozměry položky (D x Š x V) | 6 x 5 x 1 palce |
| Hmotnost položky | 4 unce |
| Vnější povrch | Painted (internal component, no decorative finish) |
| Specifikace splněna | ASME |
| Zahrnuté komponenty | K-1021119 Cartridge |
8. Záruka a podpora
For information regarding the warranty of your Kohler 1021119 replacement part, please refer to the warranty documentation provided with your original Kohler faucet or visit the official Kohler website. Kohler offers comprehensive customer support for their products.
- Oficiální Kohler Webmísto: www.kohler.com
- Služby zákazníkům: Contact Kohler customer service for assistance with product inquiries, troubleshooting, or warranty claims. Refer to the webstránky s aktuálními kontaktními informacemi.