1. Úvod
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Frymaster 806-0184 Operating Thermostat. This component is a genuine OEM replacement part designed for specific Frymaster fryer models. It is crucial to read and understand all instructions before proceeding with installation or operation to ensure safety, reliability, and optimal performance of your equipment.

Image 1: Frymaster 806-0184 Operating Thermostat. This image displays the thermostat unit, typically a cylindrical component with electrical terminals and a temperature sensing bulb or probe.
2. Bezpečnostní informace
VAROVÁNÍ: Nesprávná instalace, seřízení, úprava, servis nebo údržba může způsobit poškození majetku, zranění nebo smrt. Před instalací nebo servisem tohoto zařízení si důkladně přečtěte pokyny pro instalaci, provoz a údržbu.
- Always disconnect power to the fryer before performing any installation, maintenance, or service.
- Only qualified service personnel should install or service this component.
- Ensure all electrical connections are secure and comply with local and national electrical codes.
- Do not operate the fryer if any part is damaged or malfunctioning.
- Use only genuine Frymaster OEM replacement parts to ensure compatibility and safety.
3. Nastavení a instalace
The Frymaster 806-0184 is an operating thermostat designed for replacement in compatible Frymaster fryer models. Installation should only be performed by a qualified technician.
- Odpojení napájení: Ensure the fryer is completely disconnected from its power source. Verify with a voltage tester.
- Demontáž přístupového panelu: Carefully remove the necessary access panels on the fryer to expose the existing thermostat.
- Odpojení kabeláže: Note the wiring configuration of the old thermostat. Take photographs if necessary. Disconnect all wires from the old thermostat.
- Thermostat Removal: Remove the old thermostat from its mounting bracket. This may involve unscrewing fasteners or releasing klipy.
- Sensor Bulb Removal: Carefully remove the temperature sensing bulb (capillary tube) from its well within the fryer vat. Avoid bending or kinking the capillary tube.
- New Thermostat Installation: Insert the new Frymaster 806-0184 thermostat into the mounting bracket. Secure it with the appropriate fasteners.
- Sensor Bulb Installation: Gently insert the new temperature sensing bulb into the designated well in the fryer vat. Ensure it is fully seated for accurate temperature readings.
- Připojení kabeláže: Connect the wires to the new thermostat terminals according to the previously noted configuration. Ensure all connections are tight and secure.
- Opětovná instalace panelu: Replace all access panels and secure them properly.
- Testování: Restore power to the fryer and test the thermostat's functionality according to the fryer's operational guidelines.
4. Návod k obsluze
The 806-0184 Operating Thermostat functions as the primary temperature control for your Frymaster fryer. It is responsible for maintaining the set cooking temperature.
- Nastavení teploty: Adjust the temperature dial or control on your fryer's control panel to the desired cooking temperature. The operating thermostat will then regulate the heating elements to maintain this temperature.
- Monitorování teploty: Monitor the fryer's temperature gauge to ensure the thermostat is functioning correctly and maintaining the set temperature.
- Automatic Cycling: The thermostat will automatically cycle the heating elements on and off to keep the oil within the desired temperature range.
Refer to your specific Frymaster fryer model's user manual for detailed operating procedures and temperature recommendations.
5. Údržba
Regular maintenance helps ensure the longevity and accurate performance of your operating thermostat.
- Čištění: Periodically inspect the thermostat and its sensor bulb for any accumulation of grease, food debris, or carbon buildup. Clean gently with a soft cloth. Ensure the fryer is cool and power is disconnected before cleaning.
- Inspekce: Check the capillary tube for any signs of damage, kinks, or corrosion. Ensure the sensor bulb is securely seated in its well.
- Kontrola zapojení: During routine fryer maintenance, inspect the thermostat's wiring connections for looseness or signs of heat damage.
Do not attempt to repair a faulty thermostat. If the thermostat is not functioning correctly, it should be replaced by a qualified technician using a genuine OEM part.
6. Řešení problémů
This section provides guidance for common issues related to the operating thermostat. For complex problems, contact a qualified service technician.
| Problém | Možná příčina | Řešení |
|---|---|---|
| Fritéza se nehřívá | No power to fryer, faulty thermostat, tripped high-limit switch, faulty heating element. | Check power supply. Verify thermostat wiring. Reset high-limit switch if tripped. Test heating elements. Replace thermostat if faulty. |
| Příliš vysoká/nízká teplota | Faulty thermostat, improperly seated sensor bulb, incorrect temperature setting. | Verify temperature setting. Ensure sensor bulb is fully inserted into its well. Replace thermostat if it fails to regulate temperature accurately. |
| Thermostat not cycling | Faulty thermostat, wiring issue. | Inspect wiring for loose connections. Replace thermostat if it does not cycle heating elements as expected. |
7. Specifikace
Key specifications for the Frymaster 806-0184 Operating Thermostat:
- Číslo dílu: 806-0184
- Číslo modelu položky: 806-0184
- Výrobce: Prtst (OEM for Frymaster)
- Hmotnost položky: Přibližně 0.353 unce
- Rozměry produktu: Přibližně 4 x 4 x 6 cm (rozměry balení/přepravy)
- Množství v balení položky: 1
- Potřebné baterie: Žádný
- Aplikace: Operating Thermostat for Frymaster MJ35 J1C fryers (and other compatible models)
8. Záruka a podpora
For warranty information and technical support regarding the Frymaster 806-0184 Operating Thermostat, please refer to the documentation provided with your original Frymaster equipment or contact Frymaster customer service directly. As an OEM part, its warranty is typically covered under the terms of the original equipment manufacturer.
For genuine parts and service, always contact authorized Frymaster distributors or service centers. You can find more information on the official Frymaster webmísto: www.frymaster.com