This instruction manual provides comprehensive guidance for the installation, configuration, and operation of the JASCO GE Z-Wave On/Off Relay Switch, Model 45609 (ZW4001). This device is designed to integrate into your Z-Wave wireless lighting control system, enabling remote ON/OFF control of permanently installed lighting fixtures and ceiling fans.

The GE Z-Wave On/Off Relay Switch offers a convenient solution for smart home automation, compatible with various lighting types including CFL, LED, Xenon, Halogen, Fluorescent, and Incandescent. It supports both 2-way and 3-way wiring configurations when used with an auxiliary switch.

2. Důležité bezpečnostní informace

VAROVÁNÍ: RIZIKO ÚRAZU ELEKTRICKÝM PROUDEM. Installation involves high voltage wiring. Improper installation can result in serious injury or death. Always consult a qualified electrician if you are unsure about any part of the installation process.

  • ODPOJTE NAPÁJENÍ: Before installation, turn OFF the power to the switch location at the circuit breaker or fuse box.
  • POŽADOVANÝ NEUTRÁLNÍ VODIČ: This switch requires a neutral wire for operation. If your existing switch box does not have a neutral wire, consult a qualified electrician.
  • POUZE VNITŘNÍ POUŽITÍ: Toto zařízení je určeno pro použití v suchých vnitřních prostorách.
  • LOAD COMPATIBILITY: Ensure the connected load does not exceed the switch's maximum rating.
  • OVLÁDÁNÍ VENTILÁTORU: This switch provides ON/OFF control for ceiling fans; speed control is not supported.

3. Obsah balení

  • GE Z-Wave On/Off Relay Switch (Model 45609 / ZW4001)
  • Wiring Nuts (typically included, but may vary)
  • Návod k použití (tento dokument)

Poznámka: Nástěnná podložka není součástí balení a je nutné ji zakoupit samostatně.

4. Nastavení a instalace

Follow these steps carefully to install your GE Z-Wave On/Off Relay Switch. If you are unfamiliar with electrical wiring, please consult a qualified electrician.

4.1 Schéma zapojení nahořeview

The switch requires Line (Hot), Load, Neutral, and Ground connections. For 3-way installations, an auxiliary switch (e.g., GE 45610) and a traveler wire are also required.

GE Z-Wave On/Off Relay Switch without wallplate

Obrázek 1: Přední view of the GE Z-Wave On/Off Relay Switch (Model 45609) without a wallplate, showing the rocker switch and mounting bracket. The "TOP" indicator is visible at the top of the metal bracket. Electrical ratings (120VAC, 60Hz, 15A Resistive Load) are printed on the side.

4.2 kroky instalace

  1. Vypnout napájení: Locate the circuit breaker or fuse that supplies power to the switch box. Turn it OFF completely. Verify power is off using a voltage tester.
  2. Odebrat stávající přepínač: Carefully remove the wallplate and unscrew the existing switch from the wall box. Disconnect the wires from the old switch, noting which wire was connected to which terminal. It is recommended to label the wires (Line, Load, Neutral, Ground, Traveler if applicable).
  3. Identifikace vodičů:
    • Line (Hot): Connects to the electrical panel, providing power.
    • Zatížení: Connects to the light fixture or fan.
    • Neutrální: Typically white, required for the switch to operate.
    • Země: Bare copper or green wire.
    • Traveler (for 3-way): Connects to the auxiliary switch.
  4. Wire the Z-Wave Switch: Connect the wires to the GE Z-Wave switch terminals as follows:
    • Zemnící vodič: Connect to the green GROUND terminal.
    • Neutrální vodič: Connect to the white NEUTRAL terminal.
    • Vedení (žhavého) vodiče: Connect to the black LINE terminal.
    • Zaváděcí drát: Connect to the black LOAD terminal.
    • Traveler Wire (if 3-way): Connect to the red TRAVELER terminal. Cap off the traveler wire if not used.
  5. Namontujte spínač: Carefully fold the wires and push the switch into the wall box. Secure the switch with the provided screws.
  6. Instalace nástěnné desky: Attach the new wallplate (not included) over the switch.
  7. Obnovit napájení: Znovu zapněte napájení jističem.
  8. Test funkčnosti: Manually press the rocker switch to ensure the connected light or fan turns ON and OFF.
GE Z-Wave On/Off Relay Switch with wallplate

Obrázek 2: Přední view of the GE Z-Wave On/Off Relay Switch (Model 45609) with a light almond wallplate installed. This illustrates the finished appearance of the switch in a standard electrical box.

5. Návod k obsluze

5.1 Ruční ovládání

The GE Z-Wave On/Off Relay Switch can be operated manually:

  • Press the top of the rocker switch to turn the connected device ON.
  • Press the bottom of the rocker switch to turn the connected device OFF.
  • An LED indicator on the switch illuminates to show its location in a dark room.

5.2 Párování (párování) do sítě Z-Wave

To add the switch to your Z-Wave network:

  1. Place your Z-Wave controller into inclusion (pairing) mode. Refer to your controller's instruction manual for specific steps.
  2. Once the controller is in inclusion mode, quickly tap the top or bottom of the rocker switch once. The LED indicator on the switch may flash to confirm inclusion.
  3. The controller will confirm successful inclusion. You can now control the switch remotely through your Z-Wave network.

Poznámka: Pairing typically requires a light, quick tap, not a prolonged press.

5.3 Z-Wave Network Exclusion (Unpairing)

To remove the switch from your Z-Wave network:

  1. Place your Z-Wave controller into exclusion (unpairing) mode. Refer to your controller's instruction manual for specific steps.
  2. Once the controller is in exclusion mode, quickly tap the top or bottom of the rocker switch once. The LED indicator on the switch may flash to confirm exclusion.
  3. The controller will confirm successful exclusion. The switch is now removed from your Z-Wave network.

6. Údržba

  • Čištění: Chcete-li vyčistit spínač, otřete jej měkkým hadříkemamp tkanina. Nepoužívejte abrazivní čisticí prostředky nebo rozpouštědla.
  • Žádné díly opravitelné uživatelem: Uvnitř přepínače nejsou žádné součásti, které by mohl uživatel opravit. Nepokoušejte se zařízení otevírat ani opravovat.
  • Aktualizace firmwaru: Any firmware updates would be managed through your Z-Wave controller, if supported.

7. Řešení problémů

ProblémMožná příčinaŘešení
Light/Fan does not turn ON/OFF manually.
  • Do spínače není přivedeno napájení.
  • Nesprávné zapojení.
  • Uvolněné kabelové spoje.
  • Faulty bulb/fixture.
  • Zkontrolujte jistič.
  • Verify wiring against Section 4.2.
  • Ujistěte se, že všechna připojení vodičů jsou bezpečná.
  • Test with a known working bulb/fixture.
Switch does not respond to Z-Wave controller.
  • Not properly included in the Z-Wave network.
  • Ovladač je mimo dosah.
  • Rušení.
  • Perform Z-Wave exclusion, then re-inclusion (Section 5.2, 5.3).
  • Move controller closer to the switch or add Z-Wave repeaters.
  • Ensure no other devices are causing wireless interference.
LED indicator is not working.
  • Do spínače není přivedeno napájení.
  • Switch malfunction.
  • Check power and wiring.
  • Contact customer support if power is confirmed and LED remains off.

8. Specifikace

FunkceDetail
Číslo modelu45609 (ZW4001)
ZnačkaJASCO (GE)
Moc120VAC, 60Hz
Maximální zatížení15A Resistive Load
Bezdrátová technologieZ-Wave
Konfigurace zapojení2-way or 3-way (with auxiliary switch)
Neutrální drátPožadovaný
Rozměry (D x Š x V)10.49 x 5.41 x 4.45 cm (přibližně 4.13 x 2.13 x 1.75 palce)
Hmotnost113.4 g (přibližně 4 oz)
Provozní režimZAPNUTO VYPNUTO
Typ přepínačeRocker
Typ montážeWall Mount (standard electrical box)
Typ ovladačeSmartThings (compatible with other Z-Wave controllers)

9. Záruka a podpora

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the JASCO Products webUschovejte si doklad o koupi pro případ reklamace.

JASCO Products provides customer support for their Z-Wave devices. Contact information can typically be found on their official webmístě nebo na obalu produktu.

© 2023 JASCO Products. All rights reserved. GE is a trademark of General Electric Company and is under license by Jasco Products Company LLC.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.