Johnson Controls P70AA-118C

Johnson Controls P70AA-118C Condenser Fan Cycling Control

Model: P70AA-118C | Značka: Johnson Controls

1. Úvod a konecview

The Johnson Controls P70AA-118C is a robust pressure control designed for commercial refrigeration and air conditioning applications. Its primary functions include high pressure cut-out control, head-pressure control, and condenser fan cycling. This control is compatible with most common non-corrosive refrigerants and can also be utilized in other non-corrosive fluid applications. It features a single-pole, single-throw (SPST) switch configuration and is designed for a pressure range of 100 to 400 psi.

Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

Figure 1: Johnson Controls P70AA-118C control unit, packaging, and mounting bracket.

The P70AA-118C control unit and its dedicated mounting bracket.

Figure 2: The P70AA-118C control unit and its dedicated mounting bracket.

2. Klíčové vlastnosti

  • Celoocelové pouzdro a kryt: Poskytuje dlouhotrvající a robustní ochranu vnitřních součástí a zajišťuje tak odolnost v náročných podmínkách.
  • Kalibrované nastavení tlaku pomocí mířidel: Features a visible pressure scale that is fully adjustable through the range without requiring removal of the cover (on NEMA 1 enclosure models), simplifying setup.
  • Možnost ručního resetování blokování: Offers a trip-free lockout mechanism that prevents overriding or resetting until the pressure returns to the specified safe level, enhancing system safety.
  • Variety of available pressure connection styles: Allows for greater flexibility during mounting and adaptation of pressure connections to various field application requirements.
Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

Figure 3: Close-up of the control's front panel, showing the pressure adjustment scale and differential settings.

3. Specifikace

SpecifikaceHodnota
Číslo modeluP70AA-118C
ZnačkaJohnson Controls
Rozsah tlaku100 až 400 psi
Délka kapiláry36 palců
Flare Nut Size1/4 palce
Typ přepínačeSingle-Pole, Single-Throw (SPST)
MateriálOcel
Hmotnost položky1.49 libry
Rozměry produktu10.25 x 2.75 x 4.37 palce
Typ zobrazeníAnalog
VýrobceJohnson Controls
Datum první dostupnosti11. října 2012
Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

Figure 4: Detailed product label from the packaging, showing specifications including pressure range, differential, and capillary length.

4. Instalace

Installation of the P70AA-118C control should be performed by a qualified HVAC technician or electrician in accordance with all local and national electrical codes. Ensure the power supply to the system is disconnected before beginning any installation work.

4.1 Montáž

Mount the control unit in a location that is easily accessible for adjustments and maintenance, yet protected from physical damage and excessive vibration. Use the provided mounting bracket and appropriate fasteners to secure the unit firmly.

Spodní strana view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

Obrázek 5: Spodní strana view of the P70AA-118C control unit, showing mounting points and electrical conduit entry.

4.2 Capillary Tube Connection

Carefully route the 36-inch capillary tube to the desired pressure sensing point. Avoid sharp bends or kinks that could damage the tube. Connect the 1/4 inch flare nut to the system's pressure port, ensuring a tight, leak-free seal. Do not overtighten.

Úhlové view of the P70AA-118C control, highlighting the capillary tube connection.

Obrázek 6: Úhlové view of the P70AA-118C control, highlighting the capillary tube connection.

Detail of the capillary tube and 1/4 inch flare nut connection.

Figure 7: Detail of the capillary tube and 1/4 inch flare nut connection.

4.3 Elektrické zapojení

Refer to the wiring diagram provided with the control unit or the system's specific schematics. Connect the electrical wiring to the appropriate terminals within the control's enclosure. Ensure all connections are secure and properly insulated. The P70AA-118C is a single-pole, single-throw (SPST) control.

5. Návod k obsluze

Once installed and wired, the P70AA-118C control can be adjusted to the desired operating parameters. The control features a sight-set calibrated pressure adjustment for easy setting.

5.1 Setting Pressure Range

The control allows for adjustment of both the cut-out (high pressure limit) and the differential (the difference between cut-in and cut-out pressures). Use a flat-head screwdriver to adjust the set points visible through the window on the front panel. The scale indicates the pressure in PSI.

5.2 Ruční resetování blokování

If the control is equipped with a manual reset lockout, it will trip and lock the system off if the pressure exceeds a critical threshold. To reset, the pressure must return to a safe level, and then the manual reset button must be pressed. This feature prevents automatic restarts under unsafe conditions.

6. Údržba

Regular maintenance ensures the longevity and reliable operation of your Johnson Controls P70AA-118C unit. Perform the following checks periodically:

  • Vizuální kontrola: Check the control unit, capillary tube, and electrical connections for any signs of wear, corrosion, or damage.
  • Čistota: Keep the control unit clean and free from dust, dirt, and debris, which can affect performance.
  • Integrita připojení: Ensure all electrical and pressure connections remain tight and secure.
  • Kontrola funkčnosti: Periodically verify that the control is cycling the fan or cutting out at the set pressure points as expected.

7. Řešení problémů

If you encounter issues with your P70AA-118C control, consider the following common troubleshooting steps. For complex issues, always consult a qualified technician.

  • Control Not Cycling Fan:
    • Verify power supply to the control.
    • Check pressure settings; ensure they are within the system's operating range and the control's capabilities.
    • Inspect capillary tube for kinks or leaks.
    • Zkontrolujte elektrické spoje, zda nejsou uvolněné nebo korozivní.
  • Nepřesné údaje o tlaku:
    • Ensure the capillary tube is properly connected and not damaged.
    • Verify the system's actual pressure with a calibrated gauge.
  • Control Trips Frequently:
    • Check for system overpressure conditions.
    • Review the set pressure and differential settings.
    • If equipped, ensure the manual reset lockout is not being triggered by transient pressure spikes.

8. Záruka a podpora

For detailed warranty information, please refer to the official documentation provided by Johnson Controls at the time of purchase or visit the Johnson Controls official website. Support for the P70AA-118C control can be obtained through authorized distributors or by contacting Johnson Controls customer service directly.

Product packaging label displaying the model number P70AA-118C and barcode.

Figure 8: Product packaging label displaying the model number P70AA-118C and barcode (UCC/EAN Code 128: 1078502829326).

Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

Figure 9: Manufacturing origin label on the control unit, indicating 'ASSEMBLED IN MEXICO'.

© 2023 Johnson Controls. All rights reserved. This manual is for informational purposes only.

Související dokumenty - P70AA-118C

Předview Vysokotlaké regulátory Johnson Controls řady P70, P72, P170
Detailní konecview Elektromechanické tlakové regulátory Johnson Controls PENN řad P70, P72 a P170 pro vysokotlaké aplikace. Zahrnuje funkce, aplikace, tabulky výběru a křížové odkazy pro chladicí a HVAC systémy.
Předview Jednotlivé pouzdrové jednotky Johnson Controls řady 100: Technická příručka
Comprehensive engineering guide for Johnson Controls Series 100 Single Package Units, covering capacities from 70 to 105 tons. Details features, benefits, application data, nomenclature, and technical specifications for these energy-efficient HVAC units.
Předview Nápověda k nástroji Johnson Controls Controller pro systémy HVAC
This comprehensive help document provides detailed guidance for the Johnson Controls Controller Tool, covering configuration, simulation, commissioning, and troubleshooting of VAV Single Duct and other HVAC applications. It assists professionals in managing building automation systems effectively.
Předview Instalační manuál sady příslušenství: Sada třífázového jednobodového napájení pro balené produkty
Installation manual for Johnson Controls' three-phase single-point power wiring accessory kits, designed for use with PHE4, PCE4, PHE6, and PCE6 package products featuring electric heat. Includes detailed tables for model compatibility, voltage, heater kits, wiring kits, and fuse sizes, along with installation instructions and wiring diagrams.
Předview Uživatelská příručka: Venkovní split systém klimatizace a tepelné čerpadlo
Komplexní uživatelská příručka pro venkovní klimatizační jednotky s děleným systémem a tepelná čerpadla Johnson Controls Ducted Systems, která zahrnuje provoz, bezpečnostní pokyny, funkce systému, údržbu, řešení problémů a informace o omezené záruce.
Předview Technická příručka pro jednotlivé pouzdrové jednotky Johnson Controls řady 100
Komplexní technický průvodce pro jednotlivé chladicí jednotky Johnson Controls řady 100 (70–130 tun). Podrobně popisuje vlastnosti, aplikační data, fyzikální specifikace a chladicí výkon pro efektivní řešení HVAC.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.