Konec produktuview
The Red Lion RL12G05-2W2V is a 4-inch submersible deep well pump designed for reliable water supply from wells. This 1/2 HP, 2-wire, 230-volt pump delivers a maximum of 12 GPM and has a maximum shut-off head of 212 feet. It features a durable stainless steel pump casing, thermoplastic discharge, and motor bracket. The pump includes a built-in suction screen and check valve for enhanced performance and longevity. Its 2-wire, 230-volt motor integrates the control mechanism, eliminating the need for an external control box.

Image: Red Lion RL12G05-2W2V 4-inch Submersible Deep Well Pump.
Klíčové vlastnosti
- Ponorný design: This 3.9-inch diameter submersible pump is designed for 4-inch diameter driven wells or larger. It is NSF/ANSI 372 certified for potable water applications.
- Integrovaný zpětný ventil: Features a built-in check valve to prevent rapid cycling and extend motor life.
- Suction Screen: Includes a built-in suction screen to protect impellers from debris.
- Výkon: Delivers 12 Gallons Per Minute (GPM) at 30 PSI from a depth of 40 feet, with a maximum shut-off head of 212 feet.
- 2vodičová technologie: Utilizes 2-wire technology (plus ground), with the switch mechanism integrated into the pump, eliminating the need for an external control box.
- Odolná konstrukce: Constructed with a stainless steel body and glass-filled thermoplastic impellers for long-lasting performance.

Image: Internal features of the RL Series Deep Well Submersible Pump.

Image: NSF/ANSI 372 certification for clean drinking water.
Model Number Deciphering
Understanding the model number helps identify the specific characteristics of your Red Lion deep well submersible pump.

Image: How to decipher the RL Series model number.
Specifikace
| Specifikace | Detail |
|---|---|
| Číslo modelu | RL12G05-2W2V (14942402) |
| koňská síla (HP) | 1 / 2 HP |
| svtage | 230 voltů |
| Konfigurace drátu | 2-Wire (plus ground) |
| Maximální průtok | 12 galonů za minutu (GPM) |
| Maximum Lifting Height (Shut-off) | 212 stop |
| Běh Amps | 6 Amps |
| Velikost výboje | 1-1/4-inch FNPT |
| Průměr čerpadla | 3.9 palců |
| Rozměry produktu (D x Š x V) | 3.9 cm D x 3.9 cm Š x 22.5 cm V |
| Hmotnost položky | 20 libry |
| Materiál | Stainless Steel, Thermoplastic |
| Certifikace | CSA, UL listed (USA and Canada), NSF/ANSI 372 |
Rozměry

Image: Detailed dimensions of the pump.
Výkonnostní tabulka

Image: Pump performance chart indicating GPM at different depths and pressures.
Bezpečnostní informace
Always prioritize safety during installation, operation, and maintenance. Read all instructions carefully before proceeding. Electrical work should only be performed by qualified personnel.
- Před prováděním servisu čerpadla odpojte napájení.
- Zajistěte správné uzemnění, abyste zabránili úrazu elektrickým proudem.
- Během instalace a údržby používejte vhodné osobní ochranné prostředky (OOP).
- Verify that the well casing is free of debris before lowering the pump.
- Do not operate the pump dry; ensure it is fully submerged in water.

Image: Electrical experience is required for installation.
Instalace a nastavení
Proper installation is crucial for the efficient and safe operation of your deep well pump. This section provides general guidelines. Refer to the included installation manual for detailed, step-by-step instructions.
- Well Preparation: Ensure the well is clean and free of obstructions. The pump requires a 4-inch or larger well casing.
- Elektrické připojení: Connect the pump's 2-wire (plus ground) lead wires to the power supply. Use the provided waterproof splice kit for secure and watertight connections. No external control box is needed for this 2-wire pump.
- Potrubí: Attach the discharge pipe to the pump's 1-1/4-inch FNPT discharge. Use appropriate pipe and fittings, ensuring all connections are watertight. Consider using a torque arrestor to prevent pump rotation within the well.
- Spuštění čerpadla: Carefully lower the pump into the well using a safety rope or cable attached to the pump. Ensure the pump is suspended at the recommended depth, typically 5-10 feet above the bottom of the well and below the dynamic water level.
- Surface Connections: Connect the discharge pipe to your pressure tank, pressure switch, and other plumbing components. Install a check valve if not already integrated into the pump or system.
- Základní příprava systému: Once installed, prime the system according to your pressure tank and plumbing setup.
- Zapnutí: Restore power and check for proper operation and leaks.

Image: Typical deep well pump installation diagram.

Image: Piping installation tips.
Návod k obsluze
Once properly installed, the Red Lion RL12G05-2W2V pump operates automatically in conjunction with your pressure switch and pressure tank to maintain water pressure in your system.
- Počáteční spuštění: After installation and priming, turn on the power supply to the pump. The pump will begin to fill the pressure tank and build system pressure.
- Automatický provoz: The pressure switch will automatically turn the pump on when system pressure drops below the cut-in setting and turn it off when the pressure reaches the cut-out setting.
- Sledování: Periodically check the pressure gauge to ensure the pump is maintaining consistent pressure within the desired range.
- Spotřeba vody: The pump is designed to handle typical household water demands. Avoid excessive continuous operation, which can lead to overheating.
Údržba
Regular maintenance helps ensure the longevity and optimal performance of your deep well pump.
- Roční kontrola: Have a qualified professional inspect the pump and well system annually.
- Check Pressure Tank: Verify the air pre-charge in your pressure tank periodically, typically once a year, with the pump off and system drained.
- Sledujte kvalitu vody: If water quality changes (e.g., sediment, discoloration), it may indicate an issue with the well or pump.
- Poslouchejte neobvyklé zvuky: Any new or unusual noises from the pump or system should be investigated promptly.
- Chraňte před mrazem: Ensure all exposed piping and components are protected from freezing temperatures.
Odstraňování problémů
This section provides common troubleshooting steps for issues you might encounter. For complex problems, contact a qualified pump technician.
| Problém | Možná příčina | Řešení |
|---|---|---|
| Čerpadlo neběží | No power, tripped breaker, faulty pressure switch, motor issue | Check power supply and breaker. Inspect pressure switch. Consult technician for motor issues. |
| Nízký tlak vody | Low well water level, clogged screen, pipe leak, faulty pressure tank | Check well level. Clean suction screen. Inspect plumbing for leaks. Check pressure tank pre-charge. |
| Čerpadlo cykluje příliš často | Waterlogged pressure tank, small leak in system, faulty check valve | Check pressure tank pre-charge. Locate and repair leaks. Inspect or replace check valve. |
| Nedodává se žádná voda | Pump not submerged, air in system, clogged intake, pump failure | Verify pump depth. Bleed air from system. Clear intake. Consult technician. |
Informace o záruce
The Red Lion RL12G05-2W2V Submersible Deep Well Pump comes with a 3letá záruka výrobce. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the documentation included with your product or contact Red Lion customer support.
Podpora a kontakt
For further assistance, technical support, or inquiries regarding your Red Lion pump, please use the following resources:
- Online zdroje: Navštivte Red Lion Store on Amazon pro další informace o produktu a zdroje.
- Služby zákazníkům: If Amazon.com is the seller, your product is covered by the terms outlined in our manual. Our staff can assist with troubleshooting or installation.
- Záruční nároky: For items purchased within 30 days, refer to Amazon's return policy. After 30 days, if Amazon.com is the seller, refer to your owner's manual for warranty information. If another company is the seller, contact them directly.
Užitečná videa
Red Lion: Trusted for Generations
Video: Overview of the Red Lion brand's history and commitment to quality in water movement solutions.
RL12G and RL22G Series Rotational View
Video: A rotational view of the RL12G and RL22G series submersible pumps, showcasing the exterior design and components.