1. Konec produktuview
The CyberPower CP1350PFCLCD is a mini-tower Uninterruptible Power Supply (UPS) system designed to provide battery backup and surge protection. It features sine wave output, making it compatible with active Power Factor Correction (PFC) and conventional power supplies. This unit safeguards desktop computers, workstations, networking devices, and home entertainment systems from power fluctuations and outages. An advanced multifunction color LCD panel provides real-time status and alerts, with a tilt feature for optimal viewIng.
UPS je vybaven funkcí automatickéhotage Regulation (AVR) to stabilize incoming utility power, correcting minor voltage fluctuations without engaging the battery, thereby extending battery life.

Obrázek 1: Přední strana view of the CyberPower CP1350PFCLCD UPS, showing the LCD display and control buttons.
2. Nastavení
2.1 Vybalení a počáteční kontrola
Carefully remove the UPS from its packaging. Inspect the unit for any signs of damage. Ensure all components, including the power cord and user manual, are present.
2.2 Připojení baterie
The UPS battery may be disconnected for shipping. To connect the battery:
- Locate the battery compartment cover, typically at the bottom or side of the unit.
- Remove the cover by sliding it or unscrewing retaining screws.
- Connect the internal battery cables (red to red, black to black) as indicated. Ensure connections are secure.
- Nasaďte kryt prostoru pro baterie.
2.3 Připojení k napájení a zařízením
Plug the UPS power cord into a grounded wall outlet. Connect your computer, monitor, and other critical equipment to the battery backup and surge-protected outlets on the rear of the UPS. Non-critical devices can be connected to surge-only outlets.

Obrázek 2: Zadní view of the UPS, showing 12 NEMA 5-15R outlets (six battery backup & surge protected, six surge protected), network ports, USB, and serial port.
3. Návod k obsluze
3.1 Zapnutí/vypnutí
To power on the UPS, press and hold the power button on the front panel until the LCD screen illuminates. To power off, press and hold the power button again until the display turns off.
3.2 LCD displej a ovládací prvky
The multifunction color LCD panel displays real-time information about the UPS status. Use the 'DISPLAY' button to cycle through various screens, including:
- Vstupní objemtage: Shows the incoming utility power voltage.
- Výstupní objemtage: Zobrazuje objemtagdodávaný UPS do připojených zařízení.
- Kapacita baterie: Indicates the current charge level of the battery.
- Aktuální zatížení: Shows the power consumption of connected devices.
- Odhadovaná doba běhu: Provides an approximation of how long the UPS can power connected devices during an outage.
- Záznam událostí: Records power events such as outages nebo přepětí.
The screen can be tilted up to 22 degrees for better viewing úhly.

Figure 3: Close-up of the LCD panel displaying various status icons and real-time data.
3.3 Automatická Voltage Regulace (AVR)
The UPS automatically activates AVR to correct minor voltage fluctuations (sags or surges) without switching to battery power. This ensures a stable power supply to your devices and prolongs battery life.
3.4 nabíjecí porty USB
The front panel includes USB-A and USB-C ports for convenient charging of mobile devices, even during a power outage.
4. Údržba
4.1 Výměna baterie
Over time, UPS batteries will degrade and require replacement. The CP1350PFCLCD uses two 12V sealed lead-acid batteries. The LCD panel may display an error code (e.g., E21) or a 'REPLACE' icon when the battery needs attention.
Procedure for Battery Replacement:
- Ensure the UPS is turned off and disconnected from the wall outlet.
- Remove the battery compartment cover (usually secured by two Phillips screws).
- Carefully disconnect the battery terminals (red and black) from the old batteries. Note the orientation for proper re-connection.
- Remove the old batteries. They may be snug and require gentle nudging.
- Insert the new batteries, ensuring they fit correctly.
- Connect the new battery terminals (red to red, black to black). A small spark may occur during the final connection; this is normal.
- Replace the battery compartment cover and secure it with screws.
For a visual guide on battery replacement, refer to the official product video below:
Video 1: CyberPower PFC Compatible Pure Sine Wave Tower UPS - This video demonstrates the features and setup of a CyberPower UPS, including aspects relevant to battery maintenance.
4.2 Obecná péče
Keep the UPS in a well-ventilated area, free from dust and moisture. Avoid placing it near heat sources. Regularly check for any loose connections or signs of wear.
5. Řešení problémů
If your UPS is not functioning as expected, refer to the following common issues:
| Problém | Možná příčina | Řešení |
|---|---|---|
| UPS se nezapne | Baterie není připojena nebo je vybitá | Ensure battery is connected. Charge UPS for at least 8 hours. |
| UPS nepřetržitě pípá | Přetížení nebo slabá baterie | Reduce connected load. Allow battery to charge. |
| Error Code E21 on LCD | Battery fault or end-of-life | Replace the battery as per maintenance instructions. |
| Žádná energie do zásuvek | Vypnul se jistič | Press the circuit breaker reset button on the rear panel. |
6. Specifikace
- Model: CP1350PFCLCD
- Kapacita: 1350 VA / 880 XNUMX W
- Topologie: Line Interactive with PFC Sinewave Output
- Prodejny: 12 NEMA 5-15R (6 Battery Backup & Surge Protected, 6 Surge Protected)
- Vstupní objemtage: 120 voltů
- Typ baterie: Sealed Lead Acid (2 x 12V batteries included)
- Automatický svtage Regulace (AVR): Ano
- Zobrazit: Multifunction Color LCD Panel
- Rozměry: 14.2 x 3.9 x 10.4 palce
- Hmotnost položky: 20.3 libry
7. Záruka a podpora
The CyberPower CP1350PFCLCD comes with a tříletá záruka, což zahrnuje krytí baterií. Navíc je kryto Záruka na připojená zařízení ve výši 75 000 USD, což vám zajistí klid s připojenou elektronikou.
For further support, troubleshooting, or warranty claims, please visit the official CyberPower webnebo kontaktujte jejich zákaznický servis.