The Robertshaw uni-line 712 series pilot ignition system features flame rectification with solid-state logic and flame sensing. This system provides automatic sequencing to ensure proper operation of an intermittent pilot ignition device. The 712 series pilot ignition system is designed for quick and easy installation, and includes comprehensive instructions and troubleshooting information. These systems are available with various gas valve types to suit a wide range of furnace applications, handling up to 720,000 BTU (natural gas) depending on the model. The SP845 lockout ignition control, used in the 712 lockout uni-kits, provides 90 seconds of spark followed by a six-minute time delay (purge) period between ignition attempts. After three unsuccessful tries, if no pilot flame is sensed, the SP845 enters a 1-hour lockout period. If the demand for heat persists after this lockout, the unit will automatically repeat the three ignition attempts.

Klíčové vlastnosti

  • Converts conventional standing pilot systems to intermittent pilot systems.
  • Suitable for use with residential and commercial heating equipment.
  • Includes 720-070 valve, 780-715 module, wiring harness, spark/sensor probe, and mounting hardware.
  • Inlet/outlet dimensions: 1/2 x 3/4 inches.
  • BTU capacity: 200,000 NG (Natural Gas).
Robertshaw 712-017 Pilot Ignitor System components

Obrázek 1: Nadview of the Robertshaw 712-017 Pilot Ignitor System components, including the valve, module, and wiring.

2. Bezpečnostní informace

VAROVÁNÍ: Nesprávná instalace, seřízení, úprava, servis nebo údržba může způsobit poškození majetku, zranění nebo smrt. Před instalací nebo servisem tohoto zařízení si důkladně přečtěte pokyny pro instalaci, provoz a údržbu.

  • Always disconnect electrical power and shut off the gas supply to the appliance before performing any service.
  • Instalaci a servis musí provádět kvalifikovaný instalační technik, servisní agentura nebo dodavatel plynu.
  • Ujistěte se, že všechna zapojení elektroinstalace splňují místní a národní elektrotechnické předpisy.
  • Check for gas leaks after installation or service using a soap solution; never use an open flame.
  • Neskladujte ani nepoužívejte benzín nebo jiné hořlavé výpary a kapaliny v blízkosti tohoto ani jiného spotřebiče.
  • This product is designed for natural gas (NG) applications. Refer to product specifications for compatibility with other gas types.

3. Obsah balení

Před zahájením instalace ověřte, zda jsou všechny komponenty přítomny:

  • Plynový ventil Robertshaw 720-070
  • Robertshaw 780-715 Ignition Module
  • Kabelový svazek
  • Spark/Sensor Probe Assembly
  • Montážní hardware
  • Návod k instalaci a obsluze

4. Instalace

Installation of the Robertshaw 712-017 Pilot Ignitor System should be performed by a qualified service technician. Refer to the detailed installation instructions provided with the product for specific wiring diagrams and mounting procedures.

  1. Příprava: Disconnect all electrical power to the appliance and shut off the main gas supply.
  2. Remove Old System: Carefully remove the existing pilot system and associated components, if applicable.
  3. Montážní komponenty: Mount the new 720-070 gas valve and 780-715 ignition module in appropriate locations, ensuring proper ventilation and access for service.
  4. Připojení plynového potrubí: Connect the gas piping to the new valve, ensuring all connections are tight and leak-free.
  5. Kabelová připojení: Connect the wiring harness to the ignition module, spark/sensor probe, and appliance controls according to the provided wiring diagram. Ensure all electrical connections are secure.
  6. Test těsnosti: Restore gas supply and perform a thorough leak test on all gas connections using a non-corrosive soap solution.
  7. Electrical Test: Restore electrical power and test the system operation as described in the operating instructions.

Důležité: Always verify proper operation and safety controls after installation.

5. Návod k obsluze

The Robertshaw 712-017 Pilot Ignitor System operates automatically in response to a call for heat from the thermostat.

  1. Volejte pro teplo: When the thermostat calls for heat, the ignition module initiates a sequence.
  2. Spark Ignition: The module sends a spark to the pilot burner, attempting to ignite the pilot flame.
  3. Snímání plamene: Once the pilot flame is established, the flame sensor detects its presence, signaling the module.
  4. Main Burner Ignition: Upon successful pilot ignition, the main gas valve opens, allowing gas to flow to the main burners, which are then ignited by the pilot flame.
  5. Heat Cycle Completion: The system continues to operate until the thermostat's call for heat is satisfied, at which point the main burner and pilot flame are extinguished.

Lockout Feature (SP845 Control)

  • The SP845 lockout ignition control provides 90 seconds of spark during each ignition attempt.
  • If ignition is not achieved, there is a six-minute time delay (purge) before the next attempt.
  • After three unsuccessful ignition attempts, the SP845 enters a 1-hour lockout period.
  • If the demand for heat is still present after the 1-hour lockout, the unit will automatically repeat the three ignition attempts.

6. Údržba

Regular maintenance ensures the longevity and efficient operation of your Robertshaw 712-017 Pilot Ignitor System. All maintenance should be performed by a qualified service technician.

  • Roční kontrola: Have the entire heating system, including the pilot ignitor, inspected annually by a qualified technician.
  • Čistota: Ensure the pilot burner and flame sensor are free from dust, lint, and debris. A dirty sensor can prevent proper flame detection.
  • Kontrola zapojení: Pravidelně kontrolujte veškeré kabelové spoje, zda nejsou pevně utažené a zda nevykazují známky opotřebení nebo poškození.
  • Tlak plynu: Verify that the gas pressure to the valve is within the manufacturer's specified range.
  • Integrita komponent: Inspect the gas valve and ignition module for any visible signs of damage or corrosion.

7. Řešení problémů

Before attempting any troubleshooting, ensure all safety precautions are followed, including disconnecting power and gas supply. If you are not a qualified technician, contact a professional for assistance.

ProblémMožná příčinaŘešení
No ignition/Pilot not lightingNo power to the module, no gas supply, faulty spark/sensor probe, dirty pilot burner, module in lockout.Check power supply, verify gas valve is open, inspect and clean pilot assembly, check for module lockout (wait 1 hour or reset power if applicable), test spark/sensor probe.
Main burner does not ignite after pilot lightsWeak pilot flame, faulty flame sensor, main gas valve issue.Adjust pilot flame, clean or replace flame sensor, check main gas valve operation.
System goes into lockout frequentlyIntermittent pilot ignition failure, low gas pressure, faulty module.Inspect pilot assembly for obstructions, verify gas pressure, test or replace ignition module.

For detailed troubleshooting steps and diagnostic procedures, refer to the complete manual provided with your system or consult a qualified HVAC technician.

8. Specifikace

FunkceDetail
Číslo modelu712-017
VýrobceStandard Plumbing Supply
Hmotnost položky3 libry
Rozměry produktu3 x 3 x 4.13 palce
Zahrnuté komponenty720-070 Valve, 780-715 Module, Wiring Harness, Spark/Sensor Probe, Mounting Hardware
Inlet/Outlet (Gas Valve)1/2 x 3/4 palců
BTU Capacity (Natural Gas)200,000 XNUMX BTU
Typ zapalováníPřerušovaný pilot
Lockout ControlSP845 (90 sec spark, 6 min purge, 3 tries, 1 hr lockout)

9. Záruka a podpora

Robertshaw products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official Robertshaw webmísto.

For technical support, service, or replacement parts, please contact a qualified HVAC professional or Robertshaw customer service directly. When contacting support, please have your model number (712-017) and purchase date available.

Robertshaw Webmísto: www.robertshaw.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.